Literature DB >> 33378373

Comparison of phase-resolved functional lung (PREFUL) MRI derived perfusion and ventilation parameters at 1.5T and 3T in healthy volunteers.

Julian Glandorf1,2, Filip Klimeš1,2, Andreas Voskrebenzev1,2, Marcel Gutberlet1,2, Lea Behrendt1,2, Cristian Crisosto1,2, Frank Wacker1,2, Pierluigi Ciet3, Jim M Wild4, Jens Vogel-Claussen1,2.   

Abstract

PURPOSE: The purpose of this study is to evaluate the influence of different field strengths on perfusion and ventilation parameters, SNR and CNR derived by PREFUL MRI using predefined sequence parameters.
METHODS: Data sets of free breathing 2d FLASH lung MRI were acquired from 15 healthy subjects at 1.5T and 3T (Magnetom Avanto and Skyra, Siemens Healthcare, Erlangen, Germany) with a maximum period of 3 days in between. The processed functional parameters regional ventilation (RVent), perfusion (Q), quantified perfusion (QQuant), perfusion defect percentage (QDP), ventilation defect percentage (VDP) and ventilation-perfusion match (VQM) were compared for systematic differences. Signal- and contrast-to-noise ratio (SNR and CNR) of both acquisitions were analyzed.
RESULTS: RVent, Q, VDP, SNR and CNR presented no significant differences between 1.5T and 3T. QQuant (1.5T vs. 3T, P = 0.04), and QDP (1.5T vs. 3T, P≤0.01) decreased significantly at 3T. Consequently, VQM increased significantly (1.5T vs. 3T, P≤0.01). Skewness and kurtosis of the Q-values increased significantly at 3T (P≤0.01). The mean Sørensen-Dice coefficients between both series were 0.91 for QDP and 0.94 for VDP. The Bland-Altman analysis of both series showed mean differences of 4.29% for QDP, 1.23% for VDP and -5.15% for VQM. Using the above-mentioned parameters for three-day repeatability at two different scanners and field strengths, the retrospective power calculation showed, that a sample size of 15 can detect differences of 3.7% for QDP, of 2.9% for VDP and differences of 2.6% for VQM.
CONCLUSION: Significant differences in QDP may be related to field inhomogeneities, which is expressed by increasing skewness and kurtosis at 3T. QQuant reveals only poor reproducibility between 1.5T and 3T. RVent, Q, VDP, SNR and CNR were not altered significantly at the used sequence parameters. Healthy participants with minimal defects present high spatial agreement of QDP and VDP.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 33378373      PMCID: PMC7773267          DOI: 10.1371/journal.pone.0244638

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  43 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Echo time dependence of observed T1 in the human lung.

Authors:  Simon M F Triphan; Bertram J Jobst; Felix A Breuer; Mark O Wielpütz; Hans-Ulrich Kauczor; Jürgen Biederer; Peter M Jakob
Journal:  J Magn Reson Imaging       Date:  2015-01-21       Impact factor: 4.813

3.  Functional MRI using Fourier decomposition of lung signal: reproducibility of ventilation- and perfusion-weighted imaging in healthy volunteers.

Authors:  Mathieu Lederlin; Grzegorz Bauman; Monika Eichinger; Julien Dinkel; Mathilde Brault; Jürgen Biederer; Michael Puderbach
Journal:  Eur J Radiol       Date:  2013-01-05       Impact factor: 3.528

4.  Guided image filtering.

Authors:  Kaiming He; Jian Sun; Xiaoou Tang
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2013-06       Impact factor: 6.226

5.  Effect of intravenously injected gadolinium-based contrast agents on functional lung parameters derived by PREFUL MRI.

Authors:  Julian Glandorf; Filip Klimeš; Andreas Voskrebenzev; Marcel Gutberlet; Frank Wacker; Jens Vogel-Claussen
Journal:  Magn Reson Med       Date:  2019-09-13       Impact factor: 4.668

6.  MR Imaging-derived Regional Pulmonary Parenchymal Perfusion and Cardiac Function for Monitoring Patients with Chronic Thromboembolic Pulmonary Hypertension before and after Pulmonary Endarterectomy.

Authors:  Christian Schoenfeld; Serghei Cebotari; Jan Hinrichs; Julius Renne; Till Kaireit; Karen M Olsson; Andreas Voskrebenzev; Marcel Gutberlet; Marius M Hoeper; Tobias Welte; Axel Haverich; Frank Wacker; Jens Vogel-Claussen
Journal:  Radiology       Date:  2015-12-28       Impact factor: 11.105

7.  Noninvasive Monitoring of the Response of Human Lungs to Low-Dose Lipopolysaccharide Inhalation Challenge Using MRI: A Feasibility Study.

Authors:  Agilo L Kern; Heike Biller; Filip Klimeš; Andreas Voskrebenzev; Marcel Gutberlet; Julius Renne; Meike Müller; Olaf Holz; Frank Wacker; Jens M Hohlfeld; Jens Vogel-Claussen
Journal:  J Magn Reson Imaging       Date:  2019-11-15       Impact factor: 4.813

8.  Feasibility of quantitative regional ventilation and perfusion mapping with phase-resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients.

Authors:  Andreas Voskrebenzev; Marcel Gutberlet; Filip Klimeš; Till F Kaireit; Christian Schönfeld; Alexander Rotärmel; Frank Wacker; Jens Vogel-Claussen
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

9.  Comparison of quantitative regional ventilation-weighted fourier decomposition MRI with dynamic fluorinated gas washout MRI and lung function testing in COPD patients.

Authors:  Till F Kaireit; Marcel Gutberlet; Andreas Voskrebenzev; Julia Freise; Tobias Welte; Jens M Hohlfeld; Frank Wacker; Jens Vogel-Claussen
Journal:  J Magn Reson Imaging       Date:  2017-11-21       Impact factor: 4.813

10.  Magnetic resonance lung function--a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial.

Authors:  Maren Zapke; Hans-Georg Topf; Martin Zenker; Rainer Kuth; Michael Deimling; Peter Kreisler; Manfred Rauh; Christophe Chefd'hotel; Bernhard Geiger; Thomas Rupprecht
Journal:  Respir Res       Date:  2006-08-06
View more
  2 in total

1.  A dual center and dual vendor comparison study of automated perfusion-weighted phase-resolved functional lung magnetic resonance imaging with dynamic contrast-enhanced magnetic resonance imaging in patients with cystic fibrosis.

Authors:  Lea Behrendt; Laurie J Smith; Andreas Voskrebenzev; Filip Klimeš; Till F Kaireit; Gesa H Pöhler; Agilo L Kern; Cristian Crisosto Gonzalez; Anna-Maria Dittrich; Helen Marshall; Katharina Schütz; Paul J C Hughes; Pierluigi Ciet; Harm A W M Tiddens; Jim M Wild; Jens Vogel-Claussen
Journal:  Pulm Circ       Date:  2022-04-05       Impact factor: 2.886

2.  Reproducibility of functional lung parameters derived from free-breathing non-contrast-enhanced 2D ultrashort echo-time.

Authors:  Bingjie Yang; Patrick Metze; Anke Balasch; Kilian Stumpf; Meinrad Beer; Wolfgang Rottbauer; Volker Rasche
Journal:  Quant Imaging Med Surg       Date:  2022-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.