Shuhei Ideguchi1,2, Kazuko Yamamoto2,3,4, Tatsuro Hirayama2, Takahiro Takazono2, Yoshifumi Imamura2, Taiga Miyazaki2, Noriho Sakamoto2, Koichi Izumikawa3, Katsunori Yanagihara5, Shimpei Morimoto6, Hiroshi Mukae1,2. 1. Department of Respiratory Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan. 2. Department of Respiratory Medicine, Nagasaki University Hospital, Nagasaki, Japan. 3. Department of Infection Control and Education Center, Nagasaki University Hospital, Nagasaki, Japan. 4. Clinical Research Center, National Organization Hospital, Nagasaki Medical Center, Omura, Japan. 5. Department of Laboratory Medicine, Nagasaki University Hospital, Nagasaki, Japan. 6. Innovation Platform & Office for Precision Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Abstract
Pneumocystis jirovecii pneumonia (PCP) is an opportunistic and life-threatening pulmonary infection with an increasing prevalence among individuals who are human immunodeficiency virus (HIV)-negative. Evidence regarding diagnostic testing of PCP in this patient population is insufficient. We evaluated the performance of serum (1, 3)-β-d-glucan (BDG) using the Fungitec G-test MK kit for diagnosing PCP in non-HIV patients. We retrospectively analyzed data from 219 non-HIV adult patients who underwent bronchoscopy and were tested for P. jirovecii DNA by PCR using lavage samples from the lower respiratory tract. Fifty PCP patients and 125 non-PCP patients were included. The most common underlying diseases were malignancies and systemic autoimmune diseases. Using the serum BDG Fungitec G-test MK test to diagnose PCP, the area under the receiver operating characteristic curve (AUC) was 0.924, whereas the modified cut-off value of 36.6 pg/mL had a sensitivity and specificity of 92.0% and 84.8%, respectively. The AUC for patients with systemic autoimmune diseases was 0.873, and the accuracy of serum BDG test declined when using methotrexate (MTX). In conclusion, the serum BDG test was useful for diagnosing PCP in non-HIV patients; however, the results should be carefully interpreted in case of MTX administration. LAY SUMMARY: The Fungitec G-test MK kit for measuring serum (1, 3)-β-d-glucan (BDG) levels had a sufficient diagnostic performance for Pneumocystis jirovecii pneumonia (PCP) in human immunodeficiency virus-negative patients. However, the results should be carefully interpreted in case of MTX administration.
Pneumocystis jirovecii pneumonia (PCP) is an opportunistic and life-threatening pulmonary infection with an increasing prevalence among individuals who are human immunodeficiency virus (HIV)-negative. Evidence regarding diagnostic testing of PCP in this patient population is insufficient. We evaluated the performance of serum (1, 3)-β-d-glucan (BDG) using the Fungitec G-test MK kit for diagnosing PCP in non-HIV patients. We retrospectively analyzed data from 219 non-HIV adult patients who underwent bronchoscopy and were tested for P. jirovecii DNA by PCR using lavage samples from the lower respiratory tract. Fifty PCP patients and 125 non-PCP patients were included. The most common underlying diseases were malignancies and systemic autoimmune diseases. Using the serum BDG Fungitec G-test MK test to diagnose PCP, the area under the receiver operating characteristic curve (AUC) was 0.924, whereas the modified cut-off value of 36.6 pg/mL had a sensitivity and specificity of 92.0% and 84.8%, respectively. The AUC for patients with systemic autoimmune diseases was 0.873, and the accuracy of serum BDG test declined when using methotrexate (MTX). In conclusion, the serum BDG test was useful for diagnosing PCP in non-HIV patients; however, the results should be carefully interpreted in case of MTX administration. LAY SUMMARY: The Fungitec G-test MK kit for measuring serum (1, 3)-β-d-glucan (BDG) levels had a sufficient diagnostic performance for Pneumocystis jirovecii pneumonia (PCP) in human immunodeficiency virus-negative patients. However, the results should be carefully interpreted in case of MTX administration.
Authors: Aldair Chaar-Hernandez; Jorge Montes; Maria C Rojas; Diego A Padilla-Mantilla; Abdelilah Lahmar; Juan F Toledo-Martinez; Francisco J Somoza-Cano Journal: Cureus Date: 2022-05-26