Literature DB >> 3336947

Transthoracic needle aspiration biopsy. Review of 233 cases.

R W Simpson1, D A Johnson, L E Wold, J R Goellner.   

Abstract

In 233 cases in which transthoracic needle aspiration was done at the Mayo Clinic from 1980 through 1983, the cytology slides, tissue fragments and patient histories were reviewed; the original and review diagnoses were compared and correlated with the subsequent clinical course. In most cases, the procedure was performed with an 18-gauge needle under fluoroscopic guidance, primarily in cases with suspected malignant masses that were considered to be not surgically resectable. In 70% of the cases, there was a history of malignancy, and 82% of the malignant lesions were of extrapulmonary origin. Correlation of the original diagnosis with the clinical course yielded 70% (164 cases) true positives, 6% (14 cases) true negatives, 16% (37 cases) false negatives, 0% false positives and 8% (18 cases) indeterminants. In none of the false-negative cases was the slide subsequently read as positive in a blind review. Of the true-positive cases, 12% had positive tissue fragments only, 37% had positive cytology smears only, and 51% had both positive smears and fragments. In 32% of the cases, there were radiologically demonstrable pneumothoraces, and in 12%, placement of a chest tube was required. Hemoptysis occurred in less than 5% of the cases. In summary, transthoracic needle biopsy provides an efficient way to accurately obtain diagnostic tissue, with acceptable minor complications.

Entities:  

Mesh:

Year:  1988        PMID: 3336947

Source DB:  PubMed          Journal:  Acta Cytol        ISSN: 0001-5547            Impact factor:   2.319


  4 in total

1.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

2.  Percutaneous fine needle aspiration of pulmonary mass lesions--a critical examination of the accuracy of cell typing of malignant tumours.

Authors:  W F Kealy; J M Hogan; M F Hurley
Journal:  Ir J Med Sci       Date:  1989-04       Impact factor: 1.568

3.  Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis.

Authors:  Y Lacasse; E Wong; G H Guyatt; D J Cook
Journal:  Thorax       Date:  1999-10       Impact factor: 9.139

4.  Non-diagnostic Results of Percutaneous Transthoracic Needle Biopsy: A Meta-analysis.

Authors:  Kum Ju Chae; Hyunsook Hong; Soon Ho Yoon; Seokyung Hahn; Gong Yong Jin; Chang Min Park; Jin Mo Goo
Journal:  Sci Rep       Date:  2019-08-27       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.