Hayati Ishak1, James Field2, Matthew German3. 1. Centre of Comprehensive Care Studies, Faculty of Dentistry, Universiti Teknologi MARA, Selangor, Malaysia. 2. Department of Restorative Dentistry School of Dentistry, Cardiff University, Cardiff, United Kingdom. 3. School of Dental Sciences, Translational and Clinical Research Institute, Newcastle University, Newcastle, United Kingdom.
Abstract
The difficulty in obtaining human teeth that are caries-free that have similar environmental exposure, e.g., diet intake and water fluoridation has lead researchers to opt for bovine teeth as a substitute for erosion studies. Bovine mandibular incisors are readily available at abattoirs and often originate from the same region and are likely to consume similar dietary intake. The bovine teeth for erosion or abrasion studies usually undergo specimen preparation to produce a "flat surface" baseline specimen. Among other terms used to define baseline specimens for erosion and abrasion studies include phrases like "optically flat" and "flat and smooth surface." However, these terms might have no quantitative value as it does not justify the actual surface characteristics of the prepared flattened surface. In dentistry, roughness average (Ra) is the most commonly used parameter when reporting the roughness of specimens Reporting Ra alone might not be sufficient as it does not provide information regarding the surface texture as there is no distinction between valleys and peaks, nor does it provide information about the core structure of a material unlike the bearing area curve. The incorporation of Ra and BAP values in baseline specimens has the potential in predicting the wear or lubricating potential of these specimens. Furthermore, standardization of baseline specimens by acknowledging its surface roughness values ensures comparability of erosion and abrasion studies as different specimen preparation technique might influence the outcome or results of research. European Journal of Dentistry. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).
The difficulty in obtaining human teeth that are caries-free that have similar environmental exposure, e.g., diet intake and water fluoridation has lead researchers to opt for bovine teeth as a substitute for erosion studies. Bovine mandibular incisors are readily available at abattoirs and often originate from the same region and are likely to consume similar dietary intake. The bovine teeth for erosion or abrasion studies usually undergo specimen preparation to produce a "flat surface" baseline specimen. Among other terms used to define baseline specimens for erosion and abrasion studies include phrases like "optically flat" and "flat and smooth surface." However, these terms might have no quantitative value as it does not justify the actual surface characteristics of the prepared flattened surface. In dentistry, roughness average (Ra) is the most commonly used parameter when reporting the roughness of specimens Reporting Ra alone might not be sufficient as it does not provide information regarding the surface texture as there is no distinction between valleys and peaks, nor does it provide information about the core structure of a material unlike the bearing area curve. The incorporation of Ra and BAP values in baseline specimens has the potential in predicting the wear or lubricating potential of these specimens. Furthermore, standardization of baseline specimens by acknowledging its surface roughness values ensures comparability of erosion and abrasion studies as different specimen preparation technique might influence the outcome or results of research. European Journal of Dentistry. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).
Human teeth that are caries-free and originate from the same environment are challenging to obtain in sufficient numbers.
1
Currently, most erosion and abrasion studies use bovine mandibular incisors as a substitute for human teeth. Bovine teeth are more readily available
2
and often originate from the same region and environment.
1
Furthermore, bovine teeth do not suffer from caries.
3In erosion and abrasion studies, the human or bovine teeth require some form of preparation before exposing these specimens to any wear or acidic challenges. The specimen preparation process typically involves the sectioning and embedding of teeth in a mold. Once embedding is completed, these specimens are subjected to a specific lapping and polishing procedure to produce a flat surface. The flat surface is usually described as the baseline. The terms that have been used to define the baseline for specimens are as follows; “flat surface,”
4
“optically flat,”
5
“flat and smooth surface,”
6
and “polished and ground flat.”
7
However, these terms do not represent the actual surface characteristics of a specimen. According to Las Casas et al, even the most carefully prepared surface of any material would vary in surface texture when observed at a microscopic scale.
8
Some studies go further to report the baseline based on the roughness average (Ra) value
9
10
and the bearing area parameters (BAPs),
9
while others simply optically inspect the baseline surfaces for visible defects.
11Due to the lack of standardization in lapping and polishing regimes employed in published studies, there is likely a considerable difference in enamel specimens at baseline. Silicon carbide abrasive papers of various particle sizes are commonly used for the lapping procedure with a range of lapping sequences reported; 600 grit
12
; 800 grit
4
; 400, 600, 800 grit
13
; 800, 1,200, 4,000 grit,
14
and 1,200, 4,000 grit.
10
When polishing, aluminum oxide of different particle sizes has been used; for instance 0.05 µm
9
15
; 1 and 3 µm
16
; 0.25, 1, 3, and 6 µm
17
and 1 µm.
18
However, further studies are required to determine the effects of different lapping and polishing methods on the surface roughness of enamel. To date, there have been no studies comparing the roughness parameters (Ra and BAPs) of bovine enamel specimens prepared using different silicon carbide abrasive papers. Results obtained will identify whether or not there is a need to standardize specimen preparation methods to ensure comparability between abrasion and erosion studies.A possible way of establishing standardization of the specimens at baseline is by preparing the samples with (1) a standard lapping and polishing procedure and; (2) a standard depth of enamel removal.
19
Thereafter, the measurement of roughness is needed to ensure the effectiveness of the lapping and polishing methods in producing baseline specimens with similar roughness values. Ra is a possible way of verifying the surface roughness for these specimens. However, the Ra value has its limitation as it only proves the mean values of roughness across the surface. The BAPs are a potentially valuable measurement for roughness as they can provide more comprehensive information regarding the surface characteristics, e.g., proportions of peaks and valleys of the surface. Furthermore, with the understanding of the roughness parameters of the specimens at baseline, the behavior of these specimens toward wear or fluid retention could be understood to a better degree. Field et al reported that although bovine and human enamel specimens had similar Ra at baseline and post-erosion, their BAP values differed. Human enamel specimens had more peaks whereas bovine enamel had more valleys at baseline suggesting that human enamel is likely to suffer early enamel loss upon erosive attacks when compared with bovine enamel.
9
Bovine Teeth and Human Teeth
Bovine Teeth As a Substitute for Human Teeth in Erosion or Abrasion Studies
Several species are currently used as human substitutes for
in vitro
dental research involving dental hard tissues.
20
These include shark,
21
pig,
22
horse,
23
cow,
24
sheep,
23
and primate teeth.
25In recent years, almost half of
in vitro
erosion and abrasion studies have involved the use of bovine samples instead of human samples.
26
Bovine mandibular incisors are used most often.
2
7
27
The bovine mandibular incisors are readily available
2
and have a large flat surface area without defects and carious lesions.
28
Furthermore, a large flat surface can provide a specimen with a relatively uniform thickness of enamel.
28
Their increased size compared with human teeth makes bovine teeth easier to handle and mechanically process.
29
In contrast, human teeth are generally smaller, making it challenging to produce a specimen with a flat surface and uniform thickness of enamel.
28
The mean mesiodistal width of a human central incisor was reported to be approximately 8.80 mm for males and 8.67 mm for females.
30
In contrast, bovine incisors could reach up to 20 mm in mesiodistal width. The human teeth that have been used in erosion and abrasion studies include impacted third molars
4
14
and nonimpacted third molars.
31
The impacted molars exhibit areas with aprismatic enamel, surface irregularities, and projections and are less susceptible to acid dissolution when compared with nonimpacted third molars.
14
32
Besides third molars the use of second molars,
33
first molars,
33
premolars,
15
34
incisors,
35
36
37
38
and deciduous teeth
34
39
40
have also been reported as in
Table 1
.
Table 1
The type of human teeth that have been used in previous erosion or abrasion studies
Type of human teeth used in previous erosion or abrasion studies
1. Incisors
Huysmans and Thijssen, 2000, Ceci et al, 2015; Jameel et al, 2016
2. Premolars
Lussi et al, 2000; Wongkhantee et al, 2006
3. First molars
Lippert et al, 2004
4. Second molars
Lipper et al, 2004
5. Third molars
Gans et al, 2000; Newman et al,1974
6. Impacted third molars
Eisenburger and Addy, 2001; Ganss et al, 2000
7. Deciduous teeth
Amaechi et al, 1999; Lussi et al, 2000; Cherian et al, 2020
Other limitations of human teeth include the difficulty in obtaining sufficient quality since many are often extracted because of extensive caries and other defects.
2
Not only that, but it is also challenging to control the age and source of the collected human teeth, which can influence the outcome measures of research.
28
Conversely, healthy bovine teeth are easier to obtain in sufficient quantities as they do not suffer from caries.
3
For each reported study, the cattle from which the teeth are derived usually originate from the same region and are likely to be exposed to similar dietary and environmental factors.
1
Hence, the bovine teeth used in research are more similar to one another than teeth obtained from different human subjects.
1
Enamel Microstructure of Human and Bovine Teeth
Human dental enamel is the hardest tissue in the body being composed of 1 to 2% organic material, 3 to 4% of water, and 92 to 96% of inorganic matter.
41
The inorganic component consists mainly of calcium phosphate in the form of sizeable hexagonal hydroxyapatite (HAp) crystals,
42
organized into rods, or prisms which are, in turn, perpendicular to the dentine-enamel junction. These rods form a keyhole-like structure measuring approximately 5 µm in diameter.
43
44
The hydroxyapatite crystals within the keyhole structure have different orientations in the head and tail area as in
Fig. 1
.
43
45
Fig. 1
Schematic drawing of enamel microstructure showing keyhole-like rods aligned in parallel. These rods measure approximately 5 µm in diameter. The area in between the rods is known as interprism enamel. (Reproduced with permission of Habelitz et al
43
).
Schematic drawing of enamel microstructure showing keyhole-like rods aligned in parallel. These rods measure approximately 5 µm in diameter. The area in between the rods is known as interprism enamel. (Reproduced with permission of Habelitz et al
43
).The mechanical properties of enamel are influenced by the enamel rod orientation.
46
47
The angle between the amelodentinal junction (ADJ) and the enamel rods in bovine teeth ranges between 45 to 55 degrees
20
whereas, in human teeth, it ranges from 70 to 90 degrees.
48
Xu et al reported that the occlusal section, which consists of enamels rods perpendicular to the surface was more resistant to erosion when compared with the axial section.
47
48
In the axial section, approximately half the enamel prisms appeared parallel, and the other half appeared angled to the surface.
47
In contrast, another study concluded that polished enamel samples showed no significant difference in erosive depth when tooth sides were compared. However, the distal surfaces of unpolished enamel specimens were more prone to acid dissolution when compared with the occlusal, buccal, and mesial surfaces.
14The hardness value of enamel was observed to be the highest at the external surface of enamel and decreased with the depth toward the ADJ, approximately 3.5 GPa and 2 to 2.5 GPa, respectively
46
or by 17%
49
suggesting that hardness value differs between layers in a tooth and could have an effect on the rate of wear.
49A study by Wang et al using scanning electron microscopy revealed two main characteristics of bovine enamel that differs from human enamel, which are:A larger size of fiber-like enamel crystals.A complicated spatial-relationship between interprisms and prisms.A bovine enamel prism contains a bundle of HAp fiber-like crystals measuring approximately 80 nm in diameter and 600 nm in length.
20
The bovine crystals are more significant in both length and thickness than human crystals as reported in studies measuring these crystals using the transmission electron microscopy. These studies revealed that each human enamel crystal is approximately 25 to 40 nm thick and 70 nm wide, respectively.
50
51
The length varied among studies ranging from 50 to 100 nm in diameter.
52
53
The larger crystals in bovine enamel might be due to the rapid development during tooth formation.
54
These large crystals contribute to the porosity of bovine enamel which causes demineralization to occur three times faster than human enamel.
24
55
Demineralization of bovine enamel is influenced by the acid-exposure times; human and bovine enamel behaved similarly at short acid exposure times (1–60 seconds). However, when the exposure time was increased (1–60 minutes), bovine enamel tissue loss progressed 30% faster than human enamel.
56
The porosity of bovine enamel causes a rapid diffusion of acid ions within enamel upon subjecting it to acid challenges. As the softened enamel layer increases in thickness, there is a greater distance for the acid ions and dissolution products to travel to and from the dissolving crystal surface causing demineralization to occur faster in bovine enamel as compared with human enamel.
57Wang et al also highlighted the difference in the orientation of the interprism crystals in bovine enamel compared with human enamel. The interprisms of bovine enamel are arranged in continuous plate-like structures between rows of enamel prisms. Moreover, the interprisms are perpendicular to the orientation of prism crystals at the prism/interprism decussating planes.
20
In contrast, interprism crystals in human enamel appeared to “lock” the prism crystals in place
58
or have a keyhole-like arrangement.
43
Therefore, the interprism/prism decussating planes do not exist.
58Although bovine enamel is a suitable substitute for human enamel in demineralization studies, it is not recommended for crack propagation studies due to its interprism/prism decussating planes which results in a weak combination of prisms causing easier crack propagation.
20
Besides that, due to the prisms being parallel on the outer surface of bovine enamel as in
Fig. 2
, it possesses lower bond strengths as compared with human enamel
3
and might not be suitable for adhesive studies either.
Fig. 2
SEM micrograph of parallel prism in the horizontal section of bovine enamel. A typical honeycomb pattern visible in the outer enamel (×10,000, bar = 1 μm). SEM, scanning electron microscopy. (Reproduced with permission of Wang et al
20
).
SEM micrograph of parallel prism in the horizontal section of bovine enamel. A typical honeycomb pattern visible in the outer enamel (×10,000, bar = 1 μm). SEM, scanning electron microscopy. (Reproduced with permission of Wang et al
20
).
Enamel Specimen Preparation in Erosion and Abrasion Studies
The main focus of this review was to establish the need for developing a reference set for polished bovine enamel samples based on surface characteristics, specifically, roughness. A search was conducted with Scopus (
http://www.scopus.com
) using the following keywords “
enamel
” AND “
erosion or abrasion
” AND “
surface roughness
.” Forty-eight studies were identified under the keywords mentioned above from the year 2000 to 2020. However, only nine studies were relevant to the preparation of bovine enamel specimens. Other studies that were not included involved human enamel (adult or primary teeth), bovine dentin, synthetic hydroxyapatite, or nondental-related enamel specimens. The information needed for this review was extracted and discussed in further detail based on these following topics: sourcing specimens; storage medium for specimens; sectioning of specimens; method of embedding specimens; lapping and polishing technique.
Sourcing Specimens
Teeth or dental hard tissues used in clinical studies should be representative of the population. Unfortunately, the environment surrounding human teeth varies in terms of fluoride therapy, salivary composition, oral hygiene, and diet
3
making interpretation of findings more difficult. Bovine teeth are often used as a substitute for human teeth because they are more readily available and often originate from the same region with similar environmental factors.
3
Additionally, as the bovine teeth composition has less variation than human teeth, the use of bovine teeth results in a more standardized test condition.
59
Furthermore, six permanent incisors are available for extraction from cattle of 18 to 36 months of age.
60In erosive or abrasive studies, bovine enamel remains the substitute for evaluating remineralization and demineralization of enamel
2
61
as it reacts similarly to acidic challenges when compared with human enamel,
2
particularly during short exposure times.
56
However, longer exposure time fastens the rate of demineralization of bovine enamel
56
due to its large hydroxyapatite crystals that cause porosity within the enamel structure thus leading to increased permeability of acid ions when compared with human enamel.
55
However, there is still a lack of research evaluating the influence of the surface characteristics or texture of polished human and bovine enamel on demineralization.
9
Storage Medium for Specimens
The bovine enamel specimens must often be decontaminated and stored before usage as extracted teeth are a potential source of cross-contamination to personnel and laboratory equipment.
62
A variety of storage media are reported in “
in vitro
” studies which include chloramine-T,
9
63
64
tapwater,
16
thymol,
10
65
and formaldehyde.
13Habelitz et al observed the reduction in hardness value of enamel when stored in deionized water or in calcium chloride (Ca-Cl
2
) buffered saline.
43
The hardness value of enamel was reported to range between 3.2 and 3.7 GPa prior to storage. However, the hardness of enamel decreased by 10% within a day of storage for both storage solutions. Furthermore, within 2 weeks, the decrease of enamel hardness was more prominent in specimens stored in Ca-Cl
2
-saline buffered solution when compared with deionized water, a reduction of hardness value of 35 and 25%, respectively.
66
Storage solutions that have been recommended by other authors are chloramine-T and formaldehyde. Chloramine-T and formaldehyde solution are disinfectants and does not alter the mechanical properties of specimen.
67
68Another study reported the impact of storage conditions of eroded bovine enamel and dentine specimens on profilometric analysis.
69
They reported that desiccated dentine causes shrinkage of exposed surface collagen and dentin bulk, thus producing different profilometric readings when compared with wet dentin samples. However, eroded enamel samples stored in wet or ambient conditions or being exposed to excessive rehydration and desiccation did not influence the performance of the profilometric measurement.
69The choice of the storage medium is essential as it might alter the mechanical properties of enamel, e.g., reduction in hardness.
66
The storage condition of enamel, either wet or desiccated, does not have an implication on the measurement of roughness using a contact stylus profilometer.
69
Sectioning of Specimens
Prior to embedding the bovine enamel specimens, the bovine teeth are visually
11
13
or microscopically
61
examined to confirm the absence of physical damage such as cracks, stains, or white spot lesions.
11
There are various ways to section an intact bovine tooth to produce enamel slabs which include using a low-speed water-cooled diamond saw,
9
16
17
63
70
slow-speed water-cooled drill,
13
high-speed rotary diamond bur,
65
or diamond disk.
10
71The dimension of the enamel slabs used in erosion or abrasion studies ranged between 4 and 10 mm in width and 2 and 4 mm in height.
13
16
17
72
As this research involves the roughness measurement of polished bovine enamel specimens using a contact stylus profilometer, the size of the enamel slabs should be determined based on the sampling length and evaluation length, which is selected, based on the Ra of the specimen.
Table 2
indicates the sampling length recommended by the British Standard 1134–2:1990 for nonperiodic profiles. Nonperiodic profiles refer to surfaces that have undergone either grinding, polishing, lapping, or super-finishing.
73
Table 2
Sampling lengths for the measurement of Ra of nonperiodic profiles reproduced from British Standard BS 1134 (e.g., ground profiles)
Ra
Sampling length (cut-off)(mm)
Over (µm)
Up to and including (µm)
0.02
0.08
0.02
0.1
0.25
0.1
2.0
0.8
2.0
10.0
2.5
10.0
80.0
8.0
Field et al and Nekrashevych et al observed an Ra of 0.13 and 0.12 µm for polished bovine enamel specimens at a sampling length of 0.3 mm and an evaluation length of 1.5 mm. According to the British Standard BS1134–2: 1990, the Ra value that ranges between 0.1 and 2.0 µm (refer
Table 2
) requires a sampling length of 0.8 mm.
73
Furthermore, a sampling length of 0.8 mm requires an evaluation length that ranges between 2.40 and 8.00 mm, as seen in
Table 3
.
Table 3
The recommended evaluation length for each sampling length, adapted from Mitutoyo Stylus Profilometer guideline (2002)
Sampling length (mm)
Evaluation length (mm)
0.08
0.4–2.00
0.25
1.25–5.00
0.80
2.40–8.00
2.50
5.00–15.00
8.00
16.00–40.00
Although the sampling and evaluation length chosen for both studies mentioned above
9
10
might not adhere to the standard recommended by the British Standard (BS) 1134 and Mitutoyo stylus profilometer guideline, which is 0.8 mm (sampling length) and 2.4 to 8.0 mm (evaluation length), respectively, instead of 0.3 and 1.5 mm, the Ra from both studies could serve as a guide in the selection of sampling length, evaluation length, and size of bovine enamel specimens for this research.
Method of Embedding Specimens
The bovine enamel specimens are embedded for easier handling and manipulation.
56
Resins used to embed enamel specimens include styrene-based resins,
9
16
18
acrylic resin,
11
63
epoxy resins,
10
slow-setting composite resin,
70
and polyurethane.
65The casting process begins by placing the sectioned enamel specimen at the base of the mold and ensuring it is centrally located.
74
The specimen can be held in place by a sticky wax to avoid movement of the specimen. Then, the casting resin is poured into a plastic mold until the desired height.
9
The casting material fully sets after 24 hours.
9
74
The removal of the embedded specimen from the mold requires the base to be removed before pressing it out of the plastic ring. Both surfaces of the cylindrical blocks that contain the embedded specimen should be parallel to ensure stability upon measurement,
74
e.g., microhardness or contact-profilometer analysis.
Lapping and Polishing Technique
The Workshop on Methodology in Erosion Research suggested that the specimens at baseline should be carefully defined and have a standardized polishing procedure and depth of material removed.
19Surface analysis requires the bovine enamel specimen’s surface to be lapped flat. The silicon carbide abrasive papers are the most commonly used material to achieve a flat surface on samples before surface analysis.
10
13
65In erosive and abrasive studies, the lapping technique mainly involves the use of silicon carbide abrasive papers of descending coarseness denoted by the ascending grit number to produce a smooth and flat surface. Among the lapping sequence used for bovine enamel specimens are 600 grit
12
; 800 grit
4
; 320, 600, and 1,200 grit
11
; 400, 600, 800 grit
13
; 600, 800, 1,000, 1,200 grit
64
; 800, 1,200, 4,000 grit,
14
and 1,200, 4,000 grit.
10
The grit number refers to the size of particles of abrading materials embedded in the silicon carbide papers which decreases as the grit number increases as summarized in
Table 4
. The particle sizes vary despite having the same grit number. For example (refer
Table 4
), ISO Grit
75
designation of P600 and CAMI Grit designation of 600, although it has the same grit number of 600, the particle size incorporated into these silicon carbide abrasive papers differs, at 25.8 and 16.0 µm, respectively.
Table 4
Represents the standard conversion and average particle diameter for the United States CAMI (Coated Manufacturers Institute) and the European FEPA (Federation of European Producers of Abrasives) “P” grading system. The FEPA system is equivalent to the ISO 6344 standard (2011)
ISO/FEPA Grit designation(P grade)
CAMI Grit designation
Average particle diameter (µm)
P60
269
60
265
P80
210
80
190
P120
125
120
115
P180
180
82
P240
58.5
240
53.0
P360
40.5
320
36.0
P400
35.0
360
28.0
P600
25.8
400
23.0
P800
21.8
500
20.0
P1000
18.3
600
16.0
P1200
15.3
800
12.6
P2000
1,000
10.3
The human enamel thickness for central incisors ranges from 0.89 to 1.06 mm,
76
whereas the enamel thickness for bovine mandibular incisors can reach up to 1.5 mm.
77
It is known that the flattening of specimens causes a varying degree of enamel removal between 100 and 400 µm
7
10
14
33
34
and exposure of crystallites which might be susceptible to abrasion.
78
Furthermore, the lapping process causes removal of surface enamel, which is highly mineralized and 100-µm thick
33
resulting in an artificially elevated measurement of tooth surface loss upon acidic challenges.
79Various methods have been advocated to ensure uniformity in the removal of enamel during the flattening procedure. Several studies have suggested these following techniques for standardization of enamel removal: (1) using a micrometer to measure the depth of enamel removal
10
; (2) consistent time for different polishing papers, 30 seconds for 600 and 60 seconds for 1,000, 1,200, and 4,000 silicon carbide abrasive papers
16
; (3) constant force, 2.83N
65
; and (4) consistent time and load, 172 g for 30 seconds.
18Several studies have incorporated the use of polishing paste of different particle sizes after the lapping procedure to produce a smooth enamel surface.
15
18
Among the particle sizes that have been used are 0.05 to 6 µm.
9
15
16
17
18
Furthermore, some studies advocate the use of ultrasonication of specimens to help remove debris caused by the lapping and polishing procedure.
10
17
56
71As mentioned earlier, there is a need in standardization of specimens at baseline in terms of polishing method and depth of material removed
19
as there has been a variety of specimen preparation being employed in previous erosive or abrasion studies. Other factors that also need to be taken into consideration are the silicon carbide abrasive paper selected as the European FEPA (ISO 6344 standard) and the United States CAMI has different particle sizes despite having the same grit number. For the measurement of roughness of polished bovine enamel specimens undergoing profilometric analysis, the selection of sampling length and evaluation length should be based on the recommendation of the British Standard 1134:1990.
Measurement of Roughness
According to the British Standard 1134–2:1990, the mechanical method or the contact profilometer remains the most commonly used technique for measuring surface roughness as compared with the optical technology.
73
Contact Profilometer: Mechanical Stylus Method
The contact profilometer is the most frequently used technique in measuring surface roughness or surface changes of dental hard tissues.
8
A contact profilometer consists of a stylus that is mechanically connected to a transducer. As the stylus moves across the specimens’ surface, it detects the surface deviations by producing an analogue signal that corresponds to the vertical movement of the stylus. The signal undergoes amplification, conditioning, and digitizing
80
81
before analysis using a commercial imaging and statistical software.
8Roughness values obtained from the stylus profilometry are dependent on the diameter of the diamond-tipped stylus.
81
82
The radius of the stylus tip has been reported to range from 0.1 to 25 µm.
61
81
82
,
83
A larger tip may distort surface roughness values
82
84
due to the inability of the stylus tip to reach the deep narrow grooves on the surface profile
80
82
as in
Fig. 3
.
Fig. 3
The effect of stylus tip radius on the profile traced. (This image is reproduced with permission of Radhakrishnan
82
).
The effect of stylus tip radius on the profile traced. (This image is reproduced with permission of Radhakrishnan
82
).Furthermore, the stylus tip is also capable of making visible scratches on softer surfaces such as enamel and dentin,
85
thus causing damages and measurement errors.
84
85
The scratches caused by profilers were seen on eroded human enamel specimens ranging from 57.6 to 577.1 nm in-depth.
86
The low pH value (pH 2.3) and longer exposure time to acidic solution (40 minutes) created the deepest scratch value. However, scratches were not found on the noneroded human enamel specimens that acted as the control group.
86
If necessary, tolerances according to DIN ISO 8785 can be set for the profilometer to filter surface imperfections, such as cracks, scratches, and dents which are not part of the measured profile.
87
Nonetheless, if the extent of damage due to the stylus is minimal and observed across all specimens, the possible differences in measurement among samples might not be affected.
88The Ra of specimens determines the sampling length selection. As suggested earlier, a sampling length of 0.8 µm is suitable for the bovine enamel specimens as studies have reported the Ra value ranging from 0.12
10
to 0.13 µm.
9
It is advisable to obtain the mean value of several observations per specimen to eliminate the variations within a specimen.
73
Noncontact Profilometer: Optical Method
The optical method is a noncontact laser method that provides the same information regarding roughness as the ones provided by the contact profilometer technique.
86
The optical technique is useful in generating a highly detailed image of the enamel surface. However, the laser has potential in penetrating the translucent enamel surface, thus creating a background noise which affects the measurement of the surface profile.
86
Furthermore, a surface that has sharp edges at the bottom of a groove causes the laser to “overshoot” hence providing misleading information regarding the surface characteristics.
89Rodriguez et al concluded that that digitization of dental materials on optical profilometers was effected by color and transparency whereby darker materials showed higher roughness values as compared with lighter materials (
p
< 0.05).
90
The advantage of optical profilometer is that it helps to overcome the need of applying a preset force (e.g., contact profilometer) which could eventually distort the research specimens.
90
However, selection of impression materials for the optical profilometry measurement is essential as darker colored impression materials produce a higher surface roughness value
91
and impression materials also have the potential risk of dimensional errors while replicating the dental tissue surfaces.
92
Roughness Parameters: Roughness Average and Bearing Area Parameters
Surface roughness refers to the variation in the height of the surface relative to a reference plane.
80
In dentistry, Ra is the most commonly used parameter in reporting surface roughness.
93Ra is the arithmetic mean of the absolute values of the vertical deviation from the mean line through the sampling length,
80
also known as the center line average.
94
The surface is considered rough if the deviations of the profile from the mean line are large and smooth if the deviations are small.
60
Ra is useful in establishing a general guideline of the surface texture of a specimen; however, it does not provide information on the surface with deep pits, sharp spikes, or the general isotropy.
9
95
Field et al recommended supplementing the Ra value with BAPs which may have benefits in predicting the behavior of human or bovine enamel toward erosive or abrasion challenges.
9The BAC or Abbott-Firestone curve was first described by Abbott and Firestone in 1933.
96
The BAC provides information on the peaks, valleys, and the core structure of the material by plotting the vertical deviations or height distribution of a surface in a negatively skewed manner,
81
97
thus producing parameters such as peak height (Rpk), core height (Rk), valley depth (Rvk), the material ratio of peaks (Mr1), and material ratio of valleys (Mr2)
96
as in
Fig. 4
Table 5
.
Fig. 4
The bearing area curve and parameters. (Adapted from Field et al
60
).
Table 5
The description of bearing area parameters (BAP) based on
Fig. 4
Bearing area parameters
Definition
Abbreviation: BAC, bearing area curve.
1. Rk (Working region or the base)
Core roughness:
A straight template covering 40% of the total is offered to the central and flattest portion of the BAC and moved until the slope is a minimum (red line in
Fig. 4
). This straight line is projected through the axes. The height that separates the two intercepts is known as core roughness, Rk.
2. Rpk (first region in contact)
Peak height:
The height of the right-angled triangle constructed from the area above the intercept (blue arrow in
Fig. 4
).
3. Rvk (lubricant retention region)
Valley depth:
The height of the triangle constructed below the intercept (green arrow in
Fig. 4
).
4. Mr1 (Peak material)
Material ratio peaks:The percentage of bearing area (peaks) found in the limits of the core profile.
5. Mr2 (Valley material)
Material ratio valleys:The percentage of bearing area (valleys) in the limits of the core profile.
The bearing area curve and parameters. (Adapted from Field et al
60
).In engineering, the BAP is also known as the functional parameters whereby it provides information on the surface that are prone wear (Rpk), the ability of the surface to retain fluid or the lubricant retention region (Rvk), and the surface texture (Rk).
98
99
The BAP serves the importance of developing a quality manufacturing process and to ensure consistent part performance, for example, the production of clutch plate design.
95
In relation to dentistry, knowing the surface characteristics using the BAC may provide information of early tooth tissue loss, the ability to retain fluid components, and the long-term resistance of dental hard tissues subjected to a variety of chemical and mechanical insults.
9
The proportion of eroded peak profiles (Mr1) for human enamel specimens decreased upon acid exposure suggesting that human enamel tends to suffer early enamel loss when compared with bovine enamel.
9
Fig. 5
illustrates the importance of BAP instead of Ra alone in evaluating the surface texture of specimens. Sample A and B had similar Ra value, but upon obtaining the BAC, sample A had deeper valleys (Rvk), whereas sample B had higher peaks (Rpk).
Fig. 5
Sample A and B surface with similar Ra. However, sample A has deeper troughs (higher Rvk), whereas sample B has higher peaks (Rpk) on the bearing area curve. (This schematic drawing is reproduced with permission of Field et al
60
).
Sample A and B surface with similar Ra. However, sample A has deeper troughs (higher Rvk), whereas sample B has higher peaks (Rpk) on the bearing area curve. (This schematic drawing is reproduced with permission of Field et al
60
).
Conclusion
In conclusion, there might be a need in standardization of specimens at baseline based on the specimen preparation method, particularly the lapping procedure and depth of enamel removal. The term “flat surface” or “optically flat” used to describe the specimens at baseline has no quantitative value as it does not justify the actual surface characteristics of the prepared flattened specimen. Currently, there are no studies on the Ra and BAP of bovine or human enamel specimens at baseline that are lapped using different silicon carbide abrasive papers. Baseline specimens should incorporate Ra and BAP values as it has potential in predicting the wear or lubricating potential of these specimens. Furthermore, standardization of baseline specimens by acknowledging its surface roughness values ensures comparability of erosion and abrasion studies as different specimen preparation technique might influence the outcome or results of research.
Authors: Ana Carolina Trentino; Ana Flavia Soares; Marco Antonio Hungaro Duarte; Sérgio Kiyoshi Ishikiriama; Rafael Francisco Lia Mondelli Journal: Photomed Laser Surg Date: 2015-07 Impact factor: 2.796