Literature DB >> 33367331

A label-free fluorescent aptasensor based on HCR and G-quadruplex DNAzymes for the detection of prostate-specific antigen.

Ruirui Zhao1, Lu Zhao2, Haidi Feng2, Xiaoliang Chen2, Huilin Zhang3, Yunfeng Bai2, Feng Feng2, Shaomin Shuang3.   

Abstract

Prostate specific antigen (PSA) has been considered as the most potential serological biomarker for the early stage detection of prostate cancer. Here, a label-free fluorescence aptasensing strategy for detecting PSA based on hybridization chain reaction (HCR) and G-quadruplex DNAzymes has been developed. This designed strategy consists of three DNA probes, aptamer probe (AP), hairpin probe 1 (H1) and hairpin probe 2 (H2). In the presence of target PSA, the aptamer sequences in AP specifically recognized PSA to form a PSA-aptamer complex, causing an AP conformation change and thus releasing the initiator, which triggered the chain-like assembly of H1 and H2 that yielded extended nicked double-stranded DNA through HCR. Upon the addition of hemin, the G-rich segments at the end of H1 and H2 self-assembled into the peroxidase-mimicking hemin/G-quadruplex DNAzymes, which catalyzed the hydrogen peroxide-mediated oxidation of thiamine to give a fluorescence signal dependent on the concentration of PSA. Under optimal conditions, a limit of detection of 0.05 nM and a linear range from 0.1 nM to 1 nM (R2 = 0.9942) were achieved by this assay. In addition, other interfering proteins, such as IgG, AFP and CEA, did not produce any significant change in the fluorescence intensity response, indicating good selectivity of this sensor for PSA detection. Finally, this proposed aptasensor was successfully used for diluted serum samples.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33367331     DOI: 10.1039/d0an02188a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

1.  An ultrasensitive and disposable electrochemical aptasensor for prostate-specific antigen (PSA) detection in real serum samples.

Authors:  Canan Özyurt; İnci Uludağ; Mustafa Kemal Sezgintürk
Journal:  Anal Bioanal Chem       Date:  2022-09-26       Impact factor: 4.478

Review 2.  Aptamer-based biosensors and application in tumor theranostics.

Authors:  Tong Mo; Xiyu Liu; Yiqun Luo; Liping Zhong; Zhikun Zhang; Tong Li; Lu Gan; Xiuli Liu; Lan Li; Huixue Wang; Xinjun Sun; Dianfa Fan; Zhangbo Qian; Pan Wu; Xiaoyuan Chen
Journal:  Cancer Sci       Date:  2021-11-16       Impact factor: 6.716

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.