FRODO pulse sequences: a new means of eliminating motion, flow, and wraparound artifacts.

R R Edelman1, D J Atkinson, M S Silver, F L Loaiza, W S Warren.   

Abstract

Magnetic resonance images of the spine, chest, abdomen, and pelvis are commonly degraded by ghost artifacts. The authors have developed a new technique named FRODO (Flow and Respiratory artifact Obliteration with Directed Orthogonal pulses) to suppress these artifacts. Signal from tissues responsible for the artifacts is eliminated by use of radio frequency pulses specifically optimized for high selectivity to saturate proton magnetization over one or more independently defined slabs (large rectangular volumes) of tissue. Ghost artifacts from pulsatile flow in the heart and blood vessels, as well as from respiratory motion and swallowing, are suppressed. Additional applications of this technique include elimination of intraluminal signal in blood vessels and suppression of wraparound artifact along the phase-encoding axis. Preliminary clinical experience suggests that the FRODO technique, in conjunction with other flow compensation methods, may provide a definitive solution to the problem of motion in spine imaging. FRODO pulse sequences may also prove useful for imaging of blood vessels, heart, abdomen, and other areas where motion, flow, or wraparound artifacts limit image quality.

Mesh:

Year:  1988        PMID: 3336685     DOI: 10.1148/radiology.166.1.3336685

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Abdominal magnetic resonance venography.

Authors:  J P Finn; H E Longmaid
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

2.  Stereoscopic display of MR angiograms.

Authors:  K U Wentz; H P Mattle; R R Edelman; J Kleefield; G V O'Reilly; C Liu; B Zhao
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

3.  Left ventricular radial tagging acquisition using gradient-recalled-echo techniques: sequence optimization.

Authors:  H Bosmans; J Bogaert; F Rademakers; G Marchal; G Laub; J Verschakelen; A L Baert
Journal:  MAGMA       Date:  1996-06       Impact factor: 2.310

4.  Young Investigator Award presentation at the 13th annual meeting of the ESMRMB, September 1996, Prague. Quantification of pulmonary water compartments by magnetic resonance.

Authors:  J Lehmann; J C Böck; P Podrabsky; W Wlodarczyk; R Felix
Journal:  MAGMA       Date:  1997-03       Impact factor: 2.310

5.  The effect of flow on blood oxygen level dependent (R* 2 ) MRI of orthotopic lung tumors.

Authors:  Heling Zhou; Olivier Belzile; Zhang Zhang; Jo Wagner; Chul Ahn; James A Richardson; Debabrata Saha; Rolf A Brekken; Ralph P Mason
Journal:  Magn Reson Med       Date:  2019-01-30       Impact factor: 4.668

6.  Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses.

Authors:  Jing Yuan; Tzu-Cheng Zhao; Yi Tang; Lawrence P Panych
Journal:  J Magn Reson Imaging       Date:  2010-07       Impact factor: 4.813

7.  The role of magnetic resonance angiography in the diagnosis of subclavian steal.

Authors:  A Carriero; L Salute; A Tartaro; A Iezzi; M Dragani; L Tamburri; L Bonomo
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Mar-Apr       Impact factor: 2.740

8.  Magnetic resonance angiography of the abdominal aorta.

Authors:  I P Arlart; L Guhl; R R Edelman
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.