Novel coronavirus (COVID-19) pandemic has been a concern for mankind and healthcare workers (HCW) for the past few months. About 5% of the patients become critically ill and require intubation and mechanical ventilation. Rapid sequence intubation (RSI) has been the cornerstone of airway management for decades. In today’s era of COVID, applying and following the conventional principles of RSI may lead to significant exposure to viral load for HCW. Pre-oxygenation using bag-and-mask ventilation (BMV) is not a recommended practice in COVID suspect or positive patients(. It has an inherent risk of aerosol generation during the procedure, which may be hazardous(. Nasal cannulas, face masks or helmet oxygenation devices are relatively safe alternatives in these patients(. During endotracheal intubation, the airway physician (AP) has to visualize the glottis for correct endotracheal tube (ETT) placement, under direct laryngoscopic vision. This may pose problems and challenges in current circumstances. Visualizing the glottis while using protective goggles and face shields is a tedious task because of the associated fogging and poor vision, a problem which most of us have encountered. Many centers use intubation box chambers and similar apparatuses to protect the AP during intubation, which adds to the challenge(. Simson JP et al. showed in their study that such devices may increase rather than decrease airborne particle exposure(. Video laryngoscopes, a necessity during these times, may not be available at all centers, especially in resource-constraint settings. This adds to the fear encountered by the emergency care providers while managing such patients, adversely affecting airway management and hence outcome of these patients. The position of an endotracheal tube needs to be confirmed before airway management is declared to be complete. End-tidal CO2 (EtCO2), the gold standard for correct confirmation of endotracheal tube, may not be available at all centers. Five-point auscultation, a practice at most centres, has a sensitivity of 94% and specificity 83%( and carries the inherent risk of aerosol generation, and hence disease transmission. It also requires at least four-five AMBU breaths before a reading displayed can be relied upon(. Auscultation of a patient to rule out right mainstem bronchus intubation is very difficult for a physician with full personal protective equipment (PPE), with safety hoods covering the head and ears. This may be especially more challenging in Emergency room settings. Point-of-care ultrasound (POCUS) can be a handy tool in this current situation. Bhoi et al. have described the role of POCUS in COVID19 pandemic(. The authors feel that POCUS can be used effectively during RSI to address the concerns associated with conventional methods of intubation and tube confirmation during RSI in COVID-19 patients (Fig. 1). Ultrasound can be used initially to locate the esophagus and access the airway anatomy in order to rule out a difficult airway. Hall et al. in their feasibility study of using ultrasound to assess airway found a good correlation with Mallampatti score(. This can help in better planning and preparation in cases of a failed attempt to intubate. Then using a linear US probe (7–12 MHz) kept transversely over the neck, we can visualize the passage of ETT through the glottis and trachea. Dynamic visualization of widening of glottis as the ETT passes through, clearly visible posterior wall of the esophagus seen post-intubation (seen as a bright hyperechoic line) and absence of ‘double-tract sign’ confirm endotracheal intubation and excludes entry of ETT in the false lumen, i.e. esophagus (Fig. 2). Exclusion of esophageal intubation can be done in real-time, hence obviating the need for re-intubation after five-point auscultation or after reading EtCO2 values(. During the post-intubation phase, POCUS is helpful to confirm that the location of ETT is correct, i.e. above the carina. the presence of left lung sliding during lung scan virtually rules out right mainstem bronchus intubation. The right subcostal view to look for diaphragm movement is found to be sensitive and specific secondary confirmatory method to check correct ETT placement(.
Fig. 1.

Integration of POCUS with Rapid Sequence Intubation

Fig. 2.

A. Transverse view of neck above the suprasternal notch at the level of thyroid showing the esophagus (red arrow). The posterior wall is seen clearly as a bright hyperechoic line (white arrow). B. Transverse view of the neck above the suprasternal notch at the level of thyroid showing esophageal intubation. the presence of a ‘double-tract sign’ (red arrow) and invisible posterior wall of the esophagus (white arrow head) confirms esophageal intubation

Integration of POCUS with Rapid Sequence Intubation A. Transverse view of neck above the suprasternal notch at the level of thyroid showing the esophagus (red arrow). The posterior wall is seen clearly as a bright hyperechoic line (white arrow). B. Transverse view of the neck above the suprasternal notch at the level of thyroid showing esophageal intubation. the presence of a ‘double-tract sign’ (red arrow) and invisible posterior wall of the esophagus (white arrow head) confirms esophageal intubation Hence, POCUS during RSI ensures that all the inherent problems and risks associated with conventional methods of intubation and tube confirmation are minimized or completely avoided. In order to minimize cross infection, a separate ultrasound machine should be designated with probe covers and low-level disinfectants can be used(. Integrating POCUS with RSI will boost confidence in HCW, decrease the strain on available health-care resources and also help in preserving the healthy work-force of hospitals. Hence, the authors advocate and recommend the use of POCUS during RSI in all patients with suspected or confirmed coronavirus disease, for whom definitive airway management is planned.

Conflict of interest

Authors do not report any financial or personal connections with other persons or organizations, which might negatively affect the contents of this publication and/or claim authorship rights to this publication.
  9 in total

1.  Staff safety during emergency airway management for COVID-19 in Hong Kong.

Authors:  Jonathan Chun-Hei Cheung; Lap Tin Ho; Justin Vincent Cheng; Esther Yin Kwan Cham; Koon Ngai Lam
Journal:  Lancet Respir Med       Date:  2020-02-24       Impact factor: 30.700

2.  Point-of-care ultrasound in COVID-19 pandemic.

Authors:  Sanjeev Bhoi; Ankit Kumar Sahu; Roshan Mathew; Tej Prakash Sinha
Journal:  Postgrad Med J       Date:  2020-05-13       Impact factor: 2.401

3.  Comparison of three different methods to confirm tracheal tube placement in emergency intubation.

Authors:  Stefek Grmec
Journal:  Intensive Care Med       Date:  2002-04-30       Impact factor: 17.440

4.  Secondary confirmation of endotracheal tube position by diaphragm motion in right subcostal ultrasound view.

Authors:  Javad Seyed Hosseini; Mohammad Taghi Talebian; Mohammad Hassan Ghafari; Vahid Eslami
Journal:  Int J Crit Illn Inj Sci       Date:  2013-04

5.  Ultrasound evaluation of the airway in the ED: a feasibility study.

Authors:  Elizabeth A Hall; Ibrahim Showaihi; Frances S Shofer; Nova L Panebianco; Anthony J Dean
Journal:  Crit Ultrasound J       Date:  2018-01-18

6.  Integration of Point-of-care Ultrasound during Rapid Sequence Intubation in Trauma Resuscitation.

Authors:  Prakash Ranjan Mishra; Sanjeev Bhoi; Tej Prakash Sinha
Journal:  J Emerg Trauma Shock       Date:  2018 Apr-Jun

7.  Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists.

Authors:  T M Cook; K El-Boghdadly; B McGuire; A F McNarry; A Patel; A Higgs
Journal:  Anaesthesia       Date:  2020-04-01       Impact factor: 6.955

8.  Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic.

Authors:  J P Simpson; D N Wong; L Verco; R Carter; M Dzidowski; P Y Chan
Journal:  Anaesthesia       Date:  2020-07-09       Impact factor: 12.893

9.  Risks to healthcare workers following tracheal intubation of patients with COVID-19: a prospective international multicentre cohort study.

Authors:  K El-Boghdadly; D J N Wong; R Owen; M D Neuman; S Pocock; J B Carlisle; C Johnstone; P Andruszkiewicz; P A Baker; B M Biccard; G L Bryson; M T V Chan; M H Cheng; K J Chin; M Coburn; M Jonsson Fagerlund; S N Myatra; P S Myles; E O'Sullivan; L Pasin; F Shamim; W A van Klei; I Ahmad
Journal:  Anaesthesia       Date:  2020-07-09       Impact factor: 12.893

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.