Literature DB >> 33357006

Modeling intra-abdominal volume and respiratory driving pressure during pneumoperitoneum insufflation-a patient-level data meta-analysis.

Guido Mazzinari1,2, Oscar Diaz-Cambronero1,2,3, Ary Serpa Neto4,5,6, Antonio Cañada Martínez7, Lucas Rovira8, María Pilar Argente Navarro1,2, Manu L N G Malbrain9,10,11, Paolo Pelosi12,13, Marcelo Gama de Abreu14,15, Markus W Hollmann4,16, Marcus J Schultz4,17,18.   

Abstract

During pneumoperitoneum, intra-abdominal pressure (IAP) is usually kept at 12-14 mmHg. There is no clinical benefit in IAP increments if they do not increase intra-abdominal volume IAV. We aimed to estimate IAV (ΔIAV) and respiratory driving pressure changes (ΔPRS) in relation to changes in IAP (ΔIAP). We carried out a patient-level meta-analysis of 204 adult patients with available data on IAV and ΔPRS during pneumoperitoneum from three trials assessing the effect of IAP on postoperative recovery and airway pressure during laparoscopic surgery under general anesthesia. The primary endpoint was ΔIAV, and the secondary endpoint was ΔPRS. The endpoints' response to ΔIAP was modeled using mixed multivariable Bayesian regression to estimate which mathematical function best fitted it. IAP values on the pressure-volume (PV) curve where the endpoint rate of change according to IAP decreased were identified. Abdomino-thoracic transmission (ATT) rate, that is, the rate ΔPRS change to ΔIAP was also estimated. The best-fitting function was sigmoid logistic and linear for IAV and ΔPRS response, respectively. Increments in IAV reached a plateau at 6.0 [95%CI 5.9-6.2] L. ΔIAV for each ΔIAP decreased at IAP ranging from 9.8 [95%CI 9.7-9.9] to 12.2 [12.0-12.3] mmHg. ATT rate was 0.65 [95%CI 0.62-0.68]. One mmHg of IAP raised ΔPRS 0.88 cmH2O. During pneumoperitoneum, IAP has a nonlinear relationship with IAV and a linear one with ΔPRS. IAP should be set below the point where IAV gains diminish.NEW & NOTEWORTHY We found that intra-abdominal volume changes related to intra-abdominal pressure increase reached a plateau with diminishing gains in commonly used pneumoperitoneum pressure ranges. We also found a linear relationship between intra-abdominal pressure and respiratory driving pressure, a known marker of postoperative pulmonary complications.

Entities:  

Keywords:  abdominal compliance; abdominal pressure; abdominal volume; laparoscopy; perioperative medicine

Mesh:

Year:  2020        PMID: 33357006     DOI: 10.1152/japplphysiol.00814.2020

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  3 in total

1.  Clinical outcomes of low-pressure pneumoperitoneum in minimally invasive urological surgery.

Authors:  Alexander West; John Hayes; Darryl Ethan Bernstein; Mahesh Krishnamoorthy; Steven Lathers; Gary Tegan; Jeremy Teoh; Prokar Dasgupta; Karel Decaestecker; Nikhil Vasdev
Journal:  J Robot Surg       Date:  2022-01-30

2.  A novel method for monitoring abdominal compliance to optimize insufflation pressure during laparoscopy.

Authors:  Frank Sterke; Willem van Weteringen; Lorenzo Ventura; Ilaria Milesi; René M H Wijnen; John Vlot; Raffaele L Dellacà
Journal:  Surg Endosc       Date:  2022-07-21       Impact factor: 3.453

Review 3.  The "Dark Side" of Pneumoperitoneum and Laparoscopy.

Authors:  Giuseppina Rosaria Umano; Giulia Delehaye; Carmine Noviello; Alfonso Papparella
Journal:  Minim Invasive Surg       Date:  2021-05-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.