Telemetric force measurements across the hip after total arthroplasty.

D T Davy1, G M Kotzar, R H Brown, K G Heiple, V M Goldberg, K G Heiple, J Berilla, A H Burstein.   

Abstract

A telemeterized total hip prosthesis was implanted in one patient and force-data were obtained. Thirty-one days postoperatively, the magnitude of the joint-contact force during double-limb stance was 1.0 times body weight. During ipsilateral single-limb stance the joint-contact force was 2.1 times body weight, and during the stance phase of gait the peak force typically was 2.6 to 2.8 times body weight, with the resultant force located on the anterosuperior portion of the ball. During stair-climbing, the force was 2.6 times body weight. At peak loads, the angle between the resultant force and the axis of the neck was 30 to 35 degrees and that between the resultant force and the plane of the prosthesis was 20 degrees. During stair-climbing or straight-leg raising, the out-of-plane orientation of the resultant force increased substantially. These data provide information concerning the forces that must be sustained by prosthetic hip joints during a number of common activities of daily living within the first month after implantation. The results also provide insight into the progression of early recovery and demonstrate the variety of forces that are generated during this period.

Entities:  

Mesh:

Year:  1988        PMID: 3335573

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  28 in total

1.  Hip joint contact forces during stumbling.

Authors:  G Bergmann; F Graichen; A Rohlmann
Journal:  Langenbecks Arch Surg       Date:  2003-11-19       Impact factor: 3.445

2.  Stemmed implants improve stability in augmented constrained condylar knees.

Authors:  Jeremy J Rawlinson; Robert F Closkey; Nicole Davis; Timothy M Wright; Russell Windsor
Journal:  Clin Orthop Relat Res       Date:  2008-08-15       Impact factor: 4.176

Review 3.  Systems analysis of bone.

Authors:  Karl J Jepsen
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2009 Jul-Aug

Review 4.  Joint contact stress: a reasonable surrogate for biological processes?

Authors:  Richard A Brand
Journal:  Iowa Orthop J       Date:  2005

Review 5.  Physical activity in the prevention and amelioration of osteoporosis in women : interaction of mechanical, hormonal and dietary factors.

Authors:  Katarina T Borer
Journal:  Sports Med       Date:  2005       Impact factor: 11.136

6.  The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem.

Authors:  Youngbae Park; Carolyne Albert; Yong-San Yoon; Göran Fernlund; Hanspeter Frei; Thomas R Oxland
Journal:  J Orthop Surg Res       Date:  2010-06-24       Impact factor: 2.359

7.  A handheld computer as part of a portable in vivo knee joint load monitoring system.

Authors:  Ja Szivek; Vs Nandakumar; Cp Geffre; Cp Townsend
Journal:  J Med Device       Date:  2008-09-01       Impact factor: 0.582

8.  Mature runt cow lumbar intradiscal pressures and motion segment biomechanics.

Authors:  Glenn Robin Buttermann; Brian P Beaubien; Louis C Saeger
Journal:  Spine J       Date:  2007-11-26       Impact factor: 4.166

9.  Serial change of sliding in intertrochanteric femoral fractures treated with sliding screw system.

Authors:  K Nakata; K Ohzono; K Hiroshima; K Toge
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

10.  In vitro fatigue failure of cemented acetabular replacements: a hip simulator study.

Authors:  N P Zant; P Heaton-Adegbile; J G Hussell; J Tong
Journal:  J Biomech Eng       Date:  2008-04       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.