Literature DB >> 33355282

Improving the aseptic transfer procedures in hospital pharmacies part A: methods for the determination of the surface bioburden on ampoules and vials.

Frits A Boom1, Paul P H Le Brun2, Stefan Boehringer3, Jos G W Kosterink4, Daan Touw4.   

Abstract

OBJECTIVES: To develop methods for surface bioburden determination of ampoules and vials to be used in the validation of the disinfection procedures and in routine monitoring of ampoules and vials.
METHODS: The surface bioburdens of ampoules and vials are determined before and after disinfection by contact plates and total immersion.
RESULTS: The mean surface bioburdens of non-disinfected ampoules and vials taken straight from the original boxes are 2.4 and 5.01 cfu (total immersion; n = 20), and 0.97 and 0.94 cfu (contact plates; n = 60). The mean surface bioburdens of ampules and vials after disinfection by wiping are 1.15 and 7.50 cfu (total immersion; n = 20), and 0.12 and 0.10 cfu (contact plates; n = 60). The high number of cfu on vials (total immersion) indicate hidden cfu around the neck not removable by wiping and not detected by contact plates. Total immersion needs special laboratory facilities and is expensive (about €50 a sample). Therefore, it is less appropriate for use in routine monitoring. However, because of the high recovery, it is the method of choice for the validation of the disinfection procedure. Surface bioburden determination by contact plates is relatively simple. Non-flat surfaces cannot be reached, but the recovery from the touched flat part of the surface is high (around 50%). The recovery from swabs is low (around 10%). Another disadvantage of swabs is the laboratory work after sampling. We therefore advise contact plates for routine monitoring. To get a reliable value of the mean surface bioburden at least 30 samples need to be examined.
CONCLUSION: Total immersion is the method of choice for the determination of the effectiveness of a disinfection procedure for ampoules and vials. Contact plate is the method of choice for routine monitoring of the surfaces of ampoules and vials. © European Association of Hospital Pharmacists 2021. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  aseptic handling; colony forming unit; contact plate; surface bioburden; total immersion

Mesh:

Year:  2019        PMID: 33355282      PMCID: PMC7788213          DOI: 10.1136/ejhpharm-2018-001672

Source DB:  PubMed          Journal:  Eur J Hosp Pharm        ISSN: 2047-9956


  4 in total

1.  Evaluation of the effectiveness of commercially available contact plates for monitoring microbial environments.

Authors:  F Pinto; S Hiom; S Girdlestone; J-Y Maillard
Journal:  Lett Appl Microbiol       Date:  2009-02-02       Impact factor: 2.858

2.  Qualification of high-recovery, flocked swabs as compared to traditional rayon swabs for microbiological environmental monitoring of surfaces.

Authors:  Giblerto Dalmaso; Manuela Bini; Roberto Paroni; Michela Ferrari
Journal:  PDA J Pharm Sci Technol       Date:  2008 May-Jun

3.  Comparison of sampling procedures for recovery of Listeria monocytogenes from stainless steel food contact surfaces.

Authors:  Diego Gómez; Agustín Ariño; Juan J Carramiñana; Carmina Rota; Javier Yangüela
Journal:  J Food Prot       Date:  2012-06       Impact factor: 2.077

4.  Evaluation of the Recovery Rate of Different Swabs for Microbial Environmental Monitoring.

Authors:  Marcel Goverde; Julian Willrodt; Alexandra Staerk
Journal:  PDA J Pharm Sci Technol       Date:  2016-08-11
  4 in total
  2 in total

1.  Improving the aseptic transfer procedures in hospital pharmacies part C: evaluation and redesign of the transfer process.

Authors:  Frits A Boom; Paul P H Le Brun; Stefan Boehringer; Jos G W Kosterink; Daan J Touw
Journal:  Eur J Hosp Pharm       Date:  2019-10-29

2.  Improving the aseptic transfer procedures in hospital pharmacies. Part B: evaluation of disinfection methods for materials with a non-sterile surface.

Authors:  Frits A Boom; Paul P H Le Brun; Stefan Boehringer; Jos G W Kosterink; Daan Touw
Journal:  Eur J Hosp Pharm       Date:  2019-08-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.