Literature DB >> 3335433

High visual contrast sensitivity in the young human infant.

A M Norcia1, C W Tyler, R D Hamer.   

Abstract

The visual evoked potential (VEP) was used to estimate photopic contrast sensitivity of 10-week-old infants over a wide range of spatial frequencies including the acuity limit. Adult and infant VEP contrast sensitivity was compared for sinusoidal luminance gratings reversed in contrast at 6 Hz. Space-average luminance was 220 cd/m2. Grating contrast was swept from well below the measured thresholds to well above them in 10 sec trials. Contrast thresholds were defined as the zero voltage intercept of the initial rising portion of the VEP amplitude versus contrast function. The VEP contrast sensitivity of 10-week-old infants was close to that of the adults for spatial frequencies below about 1 cycle (c)/deg.

Entities:  

Mesh:

Year:  1988        PMID: 3335433

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  7 in total

1.  Objective measurement of contrast sensitivity using the steady-state visual evoked potential.

Authors:  S A Chen; L Z Wu; D Z Wu
Journal:  Doc Ophthalmol       Date:  1990-09       Impact factor: 2.379

2.  Objective measurement of contrast sensitivity function using contrast sweep visual evoked responses.

Authors:  J M Lopes de Faria; O Katsumi; M Arai; T Hirose
Journal:  Br J Ophthalmol       Date:  1998-02       Impact factor: 4.638

3.  Visual cortical function in very low birth weight infants without retinal or cerebral pathology.

Authors:  Chuan Hou; Anthony M Norcia; Ashima Madan; Solina Tith; Rashi Agarwal; William V Good
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-11-25       Impact factor: 4.799

4.  Effects of sweep VEP parameters on visual acuity and contrast thresholds in children and adults.

Authors:  Fahad M Almoqbel; Naveen K Yadav; Susan J Leat; Liseann M Head; Elizabeth L Irving
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-08-06       Impact factor: 3.117

Review 5.  VEP estimation of visual acuity: a systematic review.

Authors:  Ruth Hamilton; Michael Bach; Sven P Heinrich; Michael B Hoffmann; J Vernon Odom; Daphne L McCulloch; Dorothy A Thompson
Journal:  Doc Ophthalmol       Date:  2020-06-02       Impact factor: 2.379

6.  Development of contrast mechanisms in humans: a VEP study.

Authors:  Leticia A García-Quispe; James Gordon; Vance Zemon
Journal:  Optom Vis Sci       Date:  2009-06       Impact factor: 1.973

7.  Threshold determination in sweep VEP and the effects of criterion.

Authors:  Naveen Kr Yadav; Fahad Almoqbel; Liseann Head; Elizabeth L Irving; Susan J Leat
Journal:  Doc Ophthalmol       Date:  2009-06-24       Impact factor: 2.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.