Literature DB >> 3335105

The mechanical stability of various noncemented tibial components.

R G Volz1, J K Nisbet, R W Lee, M G McMurtry.   

Abstract

Four different porous-coated tibial prosthetic implants were tested for their mechanical stability following implantation into paired cadaver tibias: Porous Coated Anatomic (PCA), Miller-Galante, Whiteside, and Anatomic Modular Knee (AMK). Following implantation the test sample was loaded eccentrically over the medial tibial plateau at 40 cycles per minute for 300,000 cycles, using an MTS machine. This represents the number of steps taken by the average person in a six- to 12-month period. Load varied sinusoidally from 5 to 115 kg. Subsidence and lift-off of the tibial plate from its bony bed was recorded for each implant, using linear variable differential transformers. The greatest degree of mechanical stability was observed with the AMK design, which is secured to the bone bed using four peripherally placed 6.5-mm cancellous screws. No motion in excess of 100 micron was observed. The central-stemmed Whiteside design and the cortical screw fixated Miller-Galante designs provided slightly less stability, each demonstrating approximately 200 micron of lift-off on the unweighted side. The PCA design exhibited the greatest amount of micromotion with subsidence and lift-off displacements of 500 micron (0.5 mm).

Entities:  

Mesh:

Year:  1988        PMID: 3335105

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  [Surface pretreatment of endoprostheses by silica/silane to optimise the hydrolytic stability between bone cement and metal. Total hip and knee arthroplasty].

Authors:  T Mumme; R Marx; R Müller-Rath; S Gravius; S Andereya; D C Wirtz
Journal:  Orthopade       Date:  2008-03       Impact factor: 1.087

2.  Longterm analysis of Sheehan total knee arthroplasty.

Authors:  J Krugluger; P Zenz; R Parzer; S Jantsch; H Häckel
Journal:  Int Orthop       Date:  1991       Impact factor: 3.075

3.  Tibial component in total knee arthroplasty: To cement or not to cement?

Authors:  P Cherubino; C Castelli; F A Grassi
Journal:  Eur J Orthop Surg Traumatol       Date:  1996-02

4.  Fixation of the tibial component in knee arthroplasty after six weeks.

Authors:  S Toksvig-Larsen; L Ryd; A Lindstrand
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

5.  Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh: a randomized clinical RSA study on cementless tibial components.

Authors:  Maiken Stilling; Frank Madsen; Anders Odgaard; Lone Rømer; Niels Trolle Andersen; Ole Rahbek; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

6.  Total knee replacement-cementless tibial fixation with screws: 10-year results.

Authors:  Önder Ersan; Alper Öztürk; Mehmet Faruk Çatma; Serhan Ünlü; Mutlu Akdoğan; Yalım Ateş
Journal:  Acta Orthop Traumatol Turc       Date:  2017-11-01       Impact factor: 1.511