Literature DB >> 3335073

Changes in myocardial repolarization in patients undergoing balloon valvuloplasty for congenital pulmonary stenosis: evidence for contraction-excitation feedback in humans.

J H Levine1, T Guarnieri, A H Kadish, R I White, H Calkins, J S Kan.   

Abstract

Alterations in ventricular loading conditions lead to changes in action potential duration and arrhythmias via contraction-excitation feedback; a decrease in load leads to prolongation of repolarization. To determine whether changes in right ventricular load alter ventricular repolarization in man, the corrected QT interval, a measure of overall ventricular repolarization, was measured in 32 patients before and after valvuloplasty for pulmonary stenosis. Right ventricular systolic pressure decreased (82.5 +/- 30.7 to 40.5 +/- 9.5 mm Hg, p less than .001) and the QTc increased concurrently (409.1 +/- 24.3 to 440.7 +/- 28.0 msec, p less than .001) after successful valvuloplasty. The increase in QTc was most marked for those patients with a greater than 30 mm Hg decrease in right ventricular pressure (40.0 +/- 23.3 vs 16.3 +/- 21.3 msec, p = .006). In a subset of seven patients in whom monophasic action potentials were recorded, monophasic action potential duration, a measure of local repolarization, was prolonged (230.0 +/- 24.3 vs 216.9 +/- 21.9, p less than .001) after successful valvuloplasty, confirming that the QTc prolongation reflected changes in local ventricular repolarization. In addition, during nine acute right ventricular outflow tract occlusions in a subset of six patients, monophasic action potential duration shortened (206.6 +/- 17.6 vs 221.7 +/- 20.9 msec, p less than .01) and early afterdepolarizations developed consistent with contraction-excitation feedback. These data suggest that, in humans, changes in mechanical load are associated with changes in ventricular repolarization consistent with contraction-excitation feedback.

Entities:  

Mesh:

Year:  1988        PMID: 3335073     DOI: 10.1161/01.cir.77.1.70

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  15 in total

1.  ECG predictors of ventricular arrhythmias and biventricular size and wall mass in tetralogy of Fallot with pulmonary regurgitation.

Authors:  W A Helbing; A A W Roest; R A Niezen; H W Vliegen; M G Hazekamp; J Ottenkamp; A de Roos; E E van der Wall
Journal:  Heart       Date:  2002-11       Impact factor: 5.994

2.  Regional changes in ventricular excitability during load manipulation of the in situ pig heart.

Authors:  J W Dean; M J Lab
Journal:  J Physiol       Date:  1990-10       Impact factor: 5.182

Review 3.  Interaction between ventricular loading and repolarisation: relevance to arrhythmogenesis.

Authors:  P Taggart; P Sutton; M Lab
Journal:  Br Heart J       Date:  1992-03

4.  Segmental wall motion abnormalities alter vulnerability to ventricular ectopic beats associated with acute increases in aortic pressure in patients with underlying coronary artery disease.

Authors:  K Siogas; S Pappas; G Graekas; J Goudevenos; G Liapi; D A Sideris
Journal:  Heart       Date:  1998-03       Impact factor: 5.994

5.  Monophasic action potential recordings during acute changes in ventricular loading induced by the Valsalva manoeuvre.

Authors:  P Taggart; P Sutton; R John; M Lab; H Swanton
Journal:  Br Heart J       Date:  1992-03

6.  Enhanced external counterpulsation therapy: significant clinical improvement without electrophysiologic remodeling.

Authors:  Charles A Henrikson; Nisha Chandra-Strobos
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-07       Impact factor: 1.468

7.  Comparative electrophysiological effects of captopril or hydralazine combined with nitrate in patients with left ventricular dysfunction and inducible ventricular tachycardia.

Authors:  Y Bashir; J F Sneddon; S O'Nunain; V E Paul; S Gibson; D E Ward; A J Camm
Journal:  Br Heart J       Date:  1992-05

Review 8.  The importance of non-uniformities in mechano-electric coupling for ventricular arrhythmias.

Authors:  T Alexander Quinn
Journal:  J Interv Card Electrophysiol       Date:  2013-12-12       Impact factor: 1.900

Review 9.  Molecular candidates for cardiac stretch-activated ion channels.

Authors:  Alistair Reed; Peter Kohl; Rémi Peyronnet
Journal:  Glob Cardiol Sci Pract       Date:  2014-06-18

Review 10.  Cardiac Mechano-Gated Ion Channels and Arrhythmias.

Authors:  Rémi Peyronnet; Jeanne M Nerbonne; Peter Kohl
Journal:  Circ Res       Date:  2016-01-22       Impact factor: 17.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.