Literature DB >> 33349597

Patient X-ray exposure and ALARA in the neonatal intensive care unit: Global patterns.

Amber J Gislason-Lee1.   

Abstract

A literature review was conducted to determine norms for practice in neonatal intensive care units (NICU) around the world, given the harmful risks associated with radiation exposure at a very young age; risk of radiation-induced harm later in life increases with every X-ray image taken, more so for younger premature babies. Empirical studies including a measurement of radiation dose in a NICU, published after the year 2000 in a peer-reviewed journal, were collected. Measured doses to patients or X-ray phantoms, number of X-rays per stay and conclusions with recommendations made in response to these values were compared for 25 studies from around the world. The number of X-rays a patient underwent during a NICU stay ranged from 0 to 159. Younger, lower birth weight patients consistently had the greatest number of X-rays per stay. Recommended action based on measured dose ranged from extensive (to minimize risk to neonates) to minimal (to reduce risk) to none (because imaging benefits outweigh patient risk), with no consistent pattern linking recommended action with dose quantity. This demonstrates a broad range of interpretations of the As Low As Reasonably Achievable (ALARA) concept. These findings indicate a disparity in the response to neonatal X-ray dose concerns on a global scale, posing a public health risk to this particular neonatal population. More up-to-date imaging protocols and dose limits specifically for the NICU environment with standardized dose monitoring would help minimize this risk to achieve the public health goals of prevention and harm reduction.
Copyright © 2020. Published by Elsevier B.V.

Entities:  

Keywords:  diagnostic X-Ray; intensive care; neonatal; radiation protection

Mesh:

Year:  2020        PMID: 33349597     DOI: 10.1016/j.pedneo.2020.10.009

Source DB:  PubMed          Journal:  Pediatr Neonatol        ISSN: 1875-9572            Impact factor:   2.083


  4 in total

Review 1.  Radiation risk issues in recurrent imaging.

Authors:  Charles Brower; Madan M Rehani
Journal:  Br J Radiol       Date:  2021-06-23       Impact factor: 3.629

2.  Organ doses in preterm and full-term neonates and infants - a retrospective study on 1,064 chest radiographs.

Authors:  Birgit Kammer; Karl O Schneider; Evi Dell'Agnolo; Michael C Seidenbusch
Journal:  Pediatr Radiol       Date:  2022-03-18

3.  A Comparative Study on X-ray Shielding and Mechanical Properties of Natural Rubber Latex Nanocomposites Containing Bi2O3 or BaSO4: Experimental and Numerical Determination.

Authors:  Arkarapol Thumwong; Manchusa Chinnawet; Preawpraw Intarasena; Chanis Rattanapongs; Shinji Tokonami; Tetsuo Ishikawa; Kiadtisak Saenboonruang
Journal:  Polymers (Basel)       Date:  2022-09-02       Impact factor: 4.967

4.  A phantom study of a protective trolley for neonatal radiographic imaging: new equipment to protect the operator from scatter radiation.

Authors:  Xinhong Wang; Mengxi Xu; Cong Chen; Zhongkun Bao; Hongzhu Wang; Jizhou Zhang; Zhen Wang; Haipeng Liu
Journal:  Pediatr Radiol       Date:  2022-08-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.