| Literature DB >> 33347939 |
R Russo1, C Levine1, C Grady1, B Peixoto1, J McCormick-Ell2, T Block2, A Gresko2, G Delmas2, P Chitale1, A Frees2, A Ruiz2, D Alland3.
Abstract
BACKGROUND: The COVID-19 pandemic has caused a severe shortage of personal protective equipment (PPE), especially N95 respirators. Efficient, effective and economically feasible methods for large-scale PPE decontamination are urgently needed. AIMS: (1) to develop protocols for effectively decontaminating PPE using vaporized hydrogen peroxide (VHP); (2) to develop novel approaches that decrease set-up and take-down time while also increasing decontamination capacity; (3) to test decontamination efficiency for N95 respirators heavily contaminated by make-up or moisturizers.Entities:
Keywords: COVID-19; Decontamination; N95 respirators; Vaporized hydrogen peroxide
Year: 2020 PMID: 33347939 PMCID: PMC7748974 DOI: 10.1016/j.jhin.2020.12.006
Source DB: PubMed Journal: J Hosp Infect ISSN: 0195-6701 Impact factor: 3.926
Figure 1N95 respirator placement for decontamination of mobile racks. (a) N95 respirators hung on the metal racks. (b) N95 respirator piles. Left to right stacks of two, four, six, eight, 10 and 12 N95 respirators. (c) Configuration of an entire rack of N95 respirators arranged in piles. (d) N95 respirators individually packaged in paper bags.
Decontamination results when N95 respirators were placed in piles of various sizes
| Respirator model | No. of respirators per pile | No. of replicates | No. of experiments | BIs and CIs results |
|---|---|---|---|---|
| Gerson 1730 (TC-84A-0160) | 4 | 3 | 4 | Pass |
| 6 | 3 | 4 | Pass | |
| 8 | 1 | 1 | Pass | |
| 10 | 1 | 1 | Pass | |
| 3M 1860S (TC-84A-0006) | 4 | 3 | 4 | Pass |
| 6 | 3 | 4 | Pass | |
| 8 | 1 | 1 | Pass | |
| 10 | 1 | 1 | BI and CI failed | |
| 12 | 1 | 1 | BI and CI failed | |
| 3M 8210 Plus | 4 | 3 | 4 | Pass |
| 6 | 3 | 3 | Pass | |
| Truline A501780 | 4 | 3 | 4 | Pass |
| 6 | 3 | 4 | Pass | |
| 8 | 1 | 1 | Pass | |
| 10 | 1 | 1 | Pass | |
| Cardinal Health N95A-S | 4 | 3 | 4 | Pass |
| 6 | 3 | 4 | Pass | |
| 8 | 1 | 2 | Pass | |
| 10 | 1 | 2 | Pass | |
| 12 | 1 | 2 | Pass |
Decontamination results when N95 respirators were covered with make-up and moisturize cream or placed inside paper bags
| Respirator model | Condition | No. of replicates | No. of experiments | BIs and CIs results |
|---|---|---|---|---|
| Halyard Fluidshield 46727/46827 | Respirator covered in moisturizer cream | 3 | 5 | Pass |
| Respirator covered in foundation | 3 | 5 | Pass | |
| Respirator covered in moisturizer cream and foundation | 3 | 5 | Pass | |
| Halyard Fluidshield 46727/46827 | Inside brown paper bag | 3 | 5 | Pass |