Literature DB >> 33346739

Accuracy of Monocular Two-Dimensional Pose Estimation Compared With a Reference Standard for Kinematic Multiview Analysis: Validation Study.

Oskar Stamm1, Anika Heimann-Steinert1.   

Abstract

BACKGROUND: Expensive optoelectronic systems, considered the gold standard, require a laboratory environment and the attachment of markers, and they are therefore rarely used in everyday clinical practice. Two-dimensional (2D) human pose estimations for clinical purposes allow kinematic analyses to be carried out via a camera-based smartphone app. Since clinical specialists highly depend on the validity of information, there is a need to evaluate the accuracy of 2D pose estimation apps.
OBJECTIVE: The aim of the study was to investigate the accuracy of the 2D pose estimation of a mobility analysis app (Lindera-v2), using the PanopticStudio Toolbox data set as a reference standard. The study aimed to assess the differences in joint angles obtained by 2D video information generated with the Lindera-v2 algorithm and the reference standard. The results can provide an important assessment of the adequacy of the app for clinical use.
METHODS: To evaluate the accuracy of the Lindera-v2 algorithm, 10 video sequences were analyzed. Accuracy was evaluated by assessing a total of 30,000 data pairs for each joint (10 joints in total), comparing the angle data obtained from the Lindera-v2 algorithm with those of the reference standard. The mean differences of the angles were calculated for each joint, and a comparison was made between the estimated values and the reference standard values. Furthermore, the mean absolute error (MAE), root mean square error, and symmetric mean absolute percentage error of the 2D angles were calculated. Agreement between the 2 measurement methods was calculated using the intraclass correlation coefficient (ICC[A,2]). A cross-correlation was calculated for the time series to verify whether there was a temporal shift in the data.
RESULTS: The mean difference of the Lindera-v2 data in the right hip was the closest to the reference standard, with a mean value difference of -0.05° (SD 6.06°). The greatest difference in comparison with the baseline was found in the neck, with a measurement of -3.07° (SD 6.43°). The MAE of the angle measurement closest to the baseline was observed in the pelvis (1.40°, SD 1.48°). In contrast, the largest MAE was observed in the right shoulder (6.48°, SD 8.43°). The medians of all acquired joints ranged in difference from 0.19° to 3.17° compared with the reference standard. The ICC values ranged from 0.951 (95% CI 0.914-0.969) in the neck to 0.997 (95% CI 0.997-0.997) in the left elbow joint. The cross-correlation showed that the Lindera-v2 algorithm had no temporal lag.
CONCLUSIONS: The results of the study indicate that a 2D pose estimation by means of a smartphone app can have excellent agreement compared with a validated reference standard. An assessment of kinematic variables can be performed with the analyzed algorithm, showing only minimal deviations compared with data from a massive multiview system. ©Oskar Stamm, Anika Heimann-Steinert. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 21.12.2020.

Entities:  

Keywords:  2D human pose estimation; analysis; clinical practice; kinematics; mobility; motion capturing; smartphone app

Mesh:

Year:  2020        PMID: 33346739      PMCID: PMC7781802          DOI: 10.2196/19608

Source DB:  PubMed          Journal:  JMIR Mhealth Uhealth        ISSN: 2291-5222            Impact factor:   4.773


  19 in total

1.  Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry.

Authors:  B Bonnechère; B Jansen; P Salvia; H Bouzahouene; L Omelina; F Moiseev; V Sholukha; J Cornelis; M Rooze; S Van Sint Jan
Journal:  Gait Posture       Date:  2013-10-05       Impact factor: 2.840

2.  Prevalence, risk factors, and burden of disease for falls and balance or walking problems among older adults in the U.S.

Authors:  Haomiao Jia; Erica I Lubetkin; Kimberly DeMichele; Debra S Stark; Matthew M Zack; William W Thompson
Journal:  Prev Med       Date:  2019-05-29       Impact factor: 4.018

Review 3.  Three-dimensional cameras and skeleton pose tracking for physical function assessment: A review of uses, validity, current developments and Kinect alternatives.

Authors:  Ross A Clark; Benjamin F Mentiplay; Emma Hough; Yong Hao Pua
Journal:  Gait Posture       Date:  2018-11-22       Impact factor: 2.840

Review 4.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation.

Authors:  Alberto Leardini; Lorenzo Chiari; Ugo Della Croce; Aurelio Cappozzo
Journal:  Gait Posture       Date:  2005-02       Impact factor: 2.840

5.  OpenPose: Realtime Multi-Person 2D Pose Estimation using Part Affinity Fields.

Authors:  Zhe Cao; Gines Hidalgo Martinez; Tomas Simon; Shih-En Wei; Yaser A Sheikh
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2019-07-17       Impact factor: 6.226

Review 6.  Validity of the Kinect for Gait Assessment: A Focused Review.

Authors:  Shmuel Springer; Galit Yogev Seligmann
Journal:  Sensors (Basel)       Date:  2016-02-04       Impact factor: 3.576

7.  Treatment of Low Back Pain with a Digital Multidisciplinary Pain Treatment App: Short-Term Results.

Authors:  Stephan Huber; Janosch A Priebe; Kaja-Maria Baumann; Anne Plidschun; Christine Schiessl; Thomas R Tölle
Journal:  JMIR Rehabil Assist Technol       Date:  2017-12-04

8.  A new accuracy measure based on bounded relative error for time series forecasting.

Authors:  Chao Chen; Jamie Twycross; Jonathan M Garibaldi
Journal:  PLoS One       Date:  2017-03-24       Impact factor: 3.240

9.  Descriptive Evaluation and Accuracy of a Mobile App to Assess Fall Risk in Seniors: Retrospective Case-Control Study.

Authors:  Sophie Rabe; Arash Azhand; Wolfgang Pommer; Swantje Müller; Anika Steinert
Journal:  JMIR Aging       Date:  2020-02-14

Review 10.  A Review of the Evolution of Vision-Based Motion Analysis and the Integration of Advanced Computer Vision Methods Towards Developing a Markerless System.

Authors:  Steffi L Colyer; Murray Evans; Darren P Cosker; Aki I T Salo
Journal:  Sports Med Open       Date:  2018-06-05
View more
  1 in total

1.  App-Based Evaluation of Older People's Fall Risk Using the mHealth App Lindera Mobility Analysis: Exploratory Study.

Authors:  Nicole Strutz; Hanna Brodowski; Joern Kiselev; Anika Heimann-Steinert; Ursula Müller-Werdan
Journal:  JMIR Aging       Date:  2022-08-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.