Literature DB >> 33339437

Interdigitated Sensor Optimization for Blood Sample Analysis.

Julien Claudel1, Thanh-Tuan Ngo1, Djilali Kourtiche1, Mustapha Nadi1.   

Abstract

Interdigitated (ITD) sensors are specially adapted for the bioimpedance analysis (BIA) of low-volume (microliter scale) biological samples. Impedance spectroscopy is a fast method involving simple and easy biological sample preparation. The geometry of an ITD sensor makes it easier to deposit a sample at the microscopic scale of the electrodes. At this scale, the electrode size induces an increase in the double-layer effect, which may completely limit interesting bandwidths in the impedance measurements. This work focuses on ITD sensor frequency band optimization via an original study of the impact of the metalization ratio α. An electrical sensor model was studied to determine the best α ratio. A ratio of 0.6 was able to improve the low-frequency cutoff by a factor of up to 2.5. This theoretical approach was confirmed by measurements of blood samples with three sensors. The optimized sensor was able to extract the intrinsic electrical properties of blood in the frequency band of interest.

Entities:  

Keywords:  biosensors; blood analysis; impedance spectroscopy; interdigitated electrodes

Mesh:

Year:  2020        PMID: 33339437      PMCID: PMC7767057          DOI: 10.3390/bios10120208

Source DB:  PubMed          Journal:  Biosensors (Basel)        ISSN: 2079-6374


  12 in total

1.  Strategies to optimize biosensors based on impedance spectroscopy to detect phytic acid using layer-by-layer films.

Authors:  Marli L Moraes; Rafael M Maki; Fernando V Paulovich; Ubirajara P Rodrigues Filho; Maria Cristina F de Oliveira; Antonio Riul; Nara C de Souza; Marystela Ferreira; Henrique L Gomes; Osvaldo N Oliveira
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

Review 2.  The dielectric properties of biological tissues: I. Literature survey.

Authors:  C Gabriel; S Gabriel; E Corthout
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

Review 3.  Biosensors: sense and sensibility.

Authors:  Anthony P F Turner
Journal:  Chem Soc Rev       Date:  2013-02-19       Impact factor: 54.564

4.  Ex vivo characterization of age-associated impedance changes of single vascular endothelial cells using micro electrical impedance spectroscopy with a cell trap.

Authors:  Yangkyu Park; Jung-Joon Cha; Seungwan Seo; Joho Yun; Hyeon Woo Kim; Changju Park; Giseok Gang; Juhun Lim; Jong-Hyun Lee
Journal:  Biomicrofluidics       Date:  2016-01-28       Impact factor: 2.800

Review 5.  Recent advances of tissue-interfaced chemical biosensors.

Authors:  Chuanrui Chen; Yue Guo; Peining Chen; Huisheng Peng
Journal:  J Mater Chem B       Date:  2020-04-29       Impact factor: 6.331

6.  The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo.

Authors:  P Steendijk; G Mur; E T Van Der Velde; J Baan
Journal:  IEEE Trans Biomed Eng       Date:  1993-11       Impact factor: 4.538

Review 7.  Highly Sensitive Biosensors Based on Biomolecules and Functional Nanomaterials Depending on the Types of Nanomaterials: A Perspective Review.

Authors:  Jinho Yoon; Minkyu Shin; Taek Lee; Jeong-Woo Choi
Journal:  Materials (Basel)       Date:  2020-01-09       Impact factor: 3.623

Review 8.  Potential diagnostic applications of biosensors: current and future directions.

Authors:  Shiping Song; Hui Xu; Chunhai Fan
Journal:  Int J Nanomedicine       Date:  2006

9.  A sensitive DNA capacitive biosensor using interdigitated electrodes.

Authors:  Lei Wang; Milena Veselinovic; Lang Yang; Brian J Geiss; David S Dandy; Tom Chen
Journal:  Biosens Bioelectron       Date:  2016-09-02       Impact factor: 10.618

10.  Use of an Insulation Layer on the Connection Tracks of a Biosensor with Coplanar Electrodes to Increase the Normalized Impedance Variation.

Authors:  Arthur Luiz Alves de Araujo; Julien Claudel; Djilali Kourtiche; Mustapha Nadi
Journal:  Biosensors (Basel)       Date:  2019-09-16
View more
  3 in total

1.  Rapid Makerspace Microfabrication and Characterization of 3D Microelectrode Arrays (3D MEAs) for Organ-on-a-Chip Models.

Authors:  Charles M Didier; Avra Kundu; Swaminathan Rajaraman
Journal:  J Microelectromech Syst       Date:  2021-09-15       Impact factor: 2.829

2.  Aptasensing nucleocapsid protein on nanodiamond assembled gold interdigitated electrodes for impedimetric SARS-CoV-2 infectious disease assessment.

Authors:  Santheraleka Ramanathan; Subash C B Gopinath; Zool Hilmi Ismail; M K Md Arshad; Prabakaran Poopalan
Journal:  Biosens Bioelectron       Date:  2021-10-27       Impact factor: 10.618

3.  RF Remote Blood Glucose Sensor and a Microfluidic Vascular Phantom for Sensor Validation.

Authors:  Muhammad Farhan Affendi Mohamad Yunos; Rémi Manczak; Cyril Guines; Ahmad Fairuzabadi Mohd Mansor; Wing Cheung Mak; Sheroz Khan; Noor Amalina Ramli; Arnaud Pothier; Anis Nurashikin Nordin
Journal:  Biosensors (Basel)       Date:  2021-12-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.