Literature DB >> 33337567

Quantification and source characterization of volatile organic compounds from exercising and application of chlorine-based cleaning products in a university athletic center.

Zachary Finewax1,2, Demetrios Pagonis1,2, Megan S Claflin3, Anne V Handschy1,2, Wyatt L Brown1,2, Olivia Jenks1,2, Benjamin A Nault1,2, Douglas A Day1,2, Brian M Lerner3, Jose L Jimenez1,2, Paul J Ziemann1,2, Joost A de Gouw1,2.   

Abstract

Humans spend approximately 90% of their time indoors, impacting their own air quality through occupancy and activities. Human VOC emissions indoors from exercise are still relatively uncertain, and questions remain about emissions from chlorine-based cleaners. To investigate these and other issues, the ATHLETic center study of Indoor Chemistry (ATHLETIC) campaign was conducted in the weight room of the Dal Ward Athletic Center at the University of Colorado Boulder. Using a Vocus Proton-Transfer-Reaction Time-of-Flight Mass Spectrometer (Vocus PTR-TOF), an Aerodyne Gas Chromatograph (GC), an Iodide-Chemical Ionization Time-of-Flight Mass Spectrometer (I-CIMS), and Picarro cavity ringdown spectrometers, we alternated measurements between the weight room and supply air, allowing for determination of VOC, NH3 , H2 O, and CO2 emission rates per person (emission factors). Human-derived emission factors were higher than previous studies of measuring indoor air quality in rooms with individuals at rest and correlated with increased CO2 emission factors. Emission factors from personal care products (PCPs) were consistent with previous studies and typically decreased throughout the day. In addition, N-chloraldimines were observed in the gas phase after the exercise equipment was cleaned with a dichlor solution. The chloraldimines likely originated from reactions of free amino acids with HOCl on gym surfaces.
© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  VOCs; chlorine chemistry; exercise; human emissions; indoor air quality; personal care products

Year:  2020        PMID: 33337567     DOI: 10.1111/ina.12781

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  1 in total

1.  Emission Rates of Volatile Organic Compounds from Humans.

Authors:  Nijing Wang; Lisa Ernle; Gabriel Bekö; Pawel Wargocki; Jonathan Williams
Journal:  Environ Sci Technol       Date:  2022-04-07       Impact factor: 11.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.