| Literature DB >> 33324111 |
Abrar N Bin Nooh1, Hend Al Nahedh1, Mohammad AlRefeai1, Fahad AlKhudhairy1.
Abstract
PURPOSE: The influence of different light-emitting diode (LED) curing light intensities on the translucency and surface gloss of bulk-fill resin-based composite (RBC) restorative materials was evaluated.Entities:
Keywords: bulk-fill resin-based composites; curing light intensity; surface gloss; translucency
Year: 2020 PMID: 33324111 PMCID: PMC7733414 DOI: 10.2147/CCIDE.S287421
Source DB: PubMed Journal: Clin Cosmet Investig Dent ISSN: 1179-1357
Restorative Materials and Polishing Systems
| Brand Name | Manufacturer | Composition |
|---|---|---|
| Filtek One bulk fill posterior | 3M ESPE, St. Paul, MN, USD | Monomer matrix: aromatic urethane dimethacrylate (AUDMA), Addition-Fragmentation monomer (AFM; dynamic stress-relieving monomer), 1,12-dodecane-DMA, and urethane dimethacrylate (UDMA) |
| Reveal HD bulk fill | BISCO, USA | Monomer matrix: urethane dimethacrylate and bisphenol A-glycidyl methacrylate (BisGMA) |
| Tetric N ceram | Ivoclar Vivadent, | Monomer matrix: dimethacrylates |
| Filtek Z350 XT (control) | 3M ESPE, St. Paul, MN, USD | Monomer matrix: Bis-GMA, UDMA, TEGDMA, and bis-EMA |
| Sof-Lex | 3M ESPE, St. Paul, MN, USD | Extra-thin contouring and polishing discs; aluminum oxide discs (coarse, 92–98 μm; medium, 25–29 μm; fine, 16–21 μm; and superfine, 2–5 μm) |
Two-Way ANOVA for Curing Light Intensity and Material for Translucency Parameter (TP) Values
| Source | Type III Sum-of-Squares | df | Mean Square | F Ratio | |
|---|---|---|---|---|---|
| Curing light intensity | 0.015 | 1 | 0.015 | 0.025 | 0.875 |
| RBC | 345.178 | 3 | 115.059 | 196.192 | 0.0001 |
| Curing light intensity x RBC | 2.873 | 1 | 0.958 | 1.633 | 0.189 |
| Error | 42.225 | 72 | 0.586 | ||
| Total | 2236.642 | 80 | |||
| Corrected total | 390.291 | 79 |
Abbreviation: RBC, resin-based composite.
One-Way ANOVA and Multiple Comparison Test (Tukey) for Translucency Parameter (TP) Values
| Curing Light Intensity | RBC Material | Mean TP Value | Standard deviation | 95% Confidence Interval for Mean | Multiple Comparison Test (Tukey) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Lower Bound | Upper Bound | Filtek Z350 | Filtek One | Tetric | Reveal | |||||
| High | Filtek Z350 | 5.533 | 0.445 | 0.000 | 5.215 | 5.852 | 1 | |||
| Filtek One | 2.238 | 0.591 | 1.815 | 2.661 | 0.000 | 1 | ||||
| Tetric N-Ceram | 3.702 | 1.176 | 2.861 | 4.543 | 0.003 | 0.017 | 1 | |||
| Reveal HD | 7.688 | 0.861 | 7.072 | 8.304 | 0.000 | 0.000 | 0.000 | 1 | ||
| Low | Filtek Z350 | 5.656 | 0.433 | 0.008 | 5.346 | 5.966 | 1 | |||
| Filtek One | 1.750 | 0.376 | 1.481 | 2.019 | 0.000 | 1 | ||||
| Tetric N-Ceram | 4.265 | 1.000 | 3.550 | 4.980 | 0.007 | 0.000 | 1 | |||
| Reveal HD | 7.600 | 0.832 | 7.004 | 8.195 | 0.000 | 0.000 | 0.000 | 1 | ||
Figure 1The effect of curing light intensity on translucency parameter (TP) values.
Two-Way ANOVA for the Gloss Values
| Source | Type III Sum-of-Squares | df | Mean Square | F-Ratio | |
|---|---|---|---|---|---|
| Curing light intensity | 27.474 | 1 | 27.474 | 0.244 | 0.623 |
| RBC | 2312.848 | 3 | 770.949 | 6.855 | 0.000 |
| Curing light intensity x RBC | 1355.622 | 3 | 451.874 | 4.018 | 0.011 |
| Error | 8097 | 72 | 112.464 | ||
| Total | 164372 | 80 | |||
| Corrected Total | 11793.39 | 79 |
One-Way ANOVA and Multiple Comparison Test (Tukey) for the Gloss Values
| Curing Light Intensity | RBC Material | Mean Gloss Value | Std. Deviation | 95% Confidence Interval for Mean | Multiple Comparison Test (Tukey) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Lower Bound | Upper Bound | Filtek Z350 | Filtek One | Tetric | Reveal HD | |||||
| High intensity | Filtek Z350 | 46.382 | 11.223 | 0.136 | 38.353 | 54.410 | 1 | |||
| Filtek One | 45.630 | 19.370 | 31.773 | 59.487 | 0.999 | 1 | ||||
| Tetric N-Ceram | 49.100 | 8.548 | 42.985 | 55.215 | 0.965 | 0.932 | 1 | |||
| Reveal HD | 35.920 | 9.878 | 28.854 | 42.986 | 0.288 | 0.351 | 0.132 | 1 | ||
| Low intensity | Filtek Z350 | 45.833 | 6.239 | 0.000 | 41.370 | 50.296 | 1 | |||
| Filtek One | 55.270 | 10.106 | 48.041 | 62.499 | 0.039 | 1 | ||||
| Tetric N-Ceram | 35.560 | 6.533 | 30.887 | 40.233 | 0.022 | 0.000 | 1 | |||
| Reveal HD | 35.680 | 6.648 | 30.924 | 40.436 | 0.024 | 0.000 | 1.000 | 1 | ||
Figure 2The effect of curing light intensity on surface gloss.