The Effects of Irradiance on Translucency and Surface Gloss of Different Bulk-Fill Composite Resins: An in vitro Study.

Abrar N Bin Nooh1, Hend Al Nahedh1, Mohammad AlRefeai1, Fahad AlKhudhairy1.   

Abstract

PURPOSE: The influence of different light-emitting diode (LED) curing light intensities on the translucency and surface gloss of bulk-fill resin-based composite (RBC) restorative materials was evaluated.
MATERIALS AND METHODS: Forty specimens of each RBC (Filtek One bulk-fill posterior, Reveal HD bulk, Tetric N-Ceram, and Filtek Z350) were prepared. The RBCs were shaped into molds and cured using an LED curing light unit at high intensity (1,200 mW/cm2) for 20 s and low intensity (650 mW/cm2) for 40 s. A spectrophotometer was used to determine the translucency, and a gloss meter was used to evaluate surface gloss. Data were analyzed using one- and two-way analysis of variance (ANOVA), independent t-test, and Tukey's and Scheffe's post hoc multiple comparison tests.
RESULTS: The highest translucency value was observed for Reveal HD (7.688 ± 0.861) with a high curing intensity, while Filtek One showed the lowest value (1.750 ± 0.376) with a low curing intensity. The materials showed no significant difference in surface gloss with a high curing intensity. With low-intensity light curing, Filtek One showed the highest gloss value (55.270 ± 10.106), while Tetric N-Ceram and Reveal HD showed the lowest gloss values (35.560 ± 6.533 and 35.680 ± 6.648, respectively).
CONCLUSION: Curing light intensity had no effect on both the gloss and translucency for all the materials tested, although for Tetric N-Ceram, higher intensity corresponded to higher gloss values while for Filtek One, higher intensity corresponded to a higher translucency value.
© 2020 Bin Nooh et al.

Entities:  

Keywords:  bulk-fill resin-based composites; curing light intensity; surface gloss; translucency

Year:  2020        PMID: 33324111      PMCID: PMC7733414          DOI: 10.2147/CCIDE.S287421

Source DB:  PubMed          Journal:  Clin Cosmet Investig Dent        ISSN: 1179-1357


Introduction

Optical properties such as translucency and surface gloss are some of the most important factors to consider when evaluating esthetics. In resin-based composites (RBCs), translucency indicates the color depth in the restoration. Translucency also influences the color harmony with the surrounding teeth or restoration.1 The translucency of RBCs is the result of the relationship between the resin matrix and the refractive indices of the filler particles. An increase in the difference will decrease the translucency of the material.2 On the other hand, surface gloss is an optical characteristic related to the distribution light that is reflected, scattered, and absorbed by the surface of an object.3 Commercially available bulk-fill resin composites can show adequate curing to depths of up to 4 mm.4 These bulk-fill materials are synthesized with certain modifications in their composition to achieve this extended depth of cure, which allows increased penetration of visible light through these materials. These modifications include an increased filler size5 such as Reveal HD bulk-fill, which manufacturers claim has an HD filler technology, and a novel photoinitiator, such as the photoinitiator in Tetric N-Ceram bulk-fill composite.6 A novel monomer system found in Filtek one bulk fill, innovative Aromatic urethane dimethacrylate (AUDMA) and Addition-fragmentation monomer (AFM). Manufacturers of these bulk-fill materials claim that they show excellent optical properties such as translucency and surface gloss, both of which are influenced by the restorative material composition,7 the type of inorganic filler particles,8 distribution, index of refraction,9,10 and the thickness of the composite restoration.11 Two indices are widely used to measure translucency—the translucency parameter (TP) and the contrast ratio (CR).12 Translucency refers to the reflectance of diffused light from a surface by a turbid medium,13 and TP indicates the translucency of the resin-based composites. TP is measured by calculating the difference in the color of the resin composite over white and black backgrounds.12 In contrast, surface gloss is measured by a gloss meter with a 60° angle of illumination, which measures the directed reflection and converts it to a reflectometer gloss value.14,15 The gloss meter is a standardized and reproducible device that has been widely used to measure the surface gloss of RBCs. As a part of efforts to improve the quality of light-curing devices, manufacturers have developed different modes of light curing that can allow rapid curing with high irradiance. The introduction of LED light curing units (LCUs) with “high power and short exposure” has been associated with multiple controversies regarding their effectiveness, role, and safety in dentistry.16 Thus, the aim of this study was to evaluate the effects of different LED curing light intensities on the translucency and surface gloss of three bulk-fill composite resin restorative materials. The hypothesis tested was that the three bulk-fill composite resin materials would show no statistically significant effect of different irradiance levels on the translucency and surface gloss.

Materials and Methods

Specimen Preparation

A total of 160 specimens, including 40 disc-shaped specimens each of Filtek One bulk-fill posterior, Reveal HD bulk fill, Tetric N-Ceram, and Filtek Z350 (control group), were fabricated, and shade A2 was selected for all the composites except Tetric N-Ceram, for which shade IVA was used (the material compositions and manufacturer details are described in Table 1). Specimens of each material were divided into four groups, of which two groups each were used to measure translucency and gloss, and they were cured using the Bluephase N LCU (Ivoclar Vivadent, Schaan, Liechtenstein, Switzerland) at a high-intensity output (1,200 mW/cm2) for 20 s or a low-intensity output (650 mW/cm2) for 40 s; the power intensity was measured using a dental Bluephase radiometer (Ivoclar vivadent, Schaan, Liechtenstein, Switzerland). For each group, ten specimens were used to measure the translucency and surface gloss. A two-part brass mold (10-mm diameter and 4-mm depth for the bulk-fill materials and 10-mm diameter and 2-mm depth was used for the conventional composite control group). After the materials were inserted into the mold, a clear Mylar strip (Mylar Uni-strip, Caulk/Dentsply, Milford, DE, USA) and a glass plate with 1.00-mm thickness were secured over it to flatten the surface and gently pressed to remove excess material on the mold.
Table 1

Restorative Materials and Polishing Systems

Brand NameManufacturerComposition
Filtek One bulk fill posterior3M ESPE, St. Paul, MN, USDMonomer matrix: aromatic urethane dimethacrylate (AUDMA), Addition-Fragmentation monomer (AFM; dynamic stress-relieving monomer), 1,12-dodecane-DMA, and urethane dimethacrylate (UDMA)Fillers: a combination of a non-agglomerated/non-aggregated 20-nm silica filler, a non-agglomerated/non-aggregated 4–11-nm zirconia filler, an aggregated zirconia/silica cluster filler (consisting of 20-nm silica and 4–11-nm zirconia particles), and a ytterbium trifluoride filler consisting of agglomerate 100-nm particles. The inorganic filler loading is about 76.5% by weight (58.4% by volume).
Reveal HD bulk fillBISCO, USAMonomer matrix: urethane dimethacrylate and bisphenol A-glycidyl methacrylate (BisGMA)Filler: Ytterbium fluoride
Tetric N ceramIvoclar Vivadent,Schaan, LiechtensteinMonomer matrix: dimethacrylatesFiller: Barium glass, YbF3 (prepolymer, ytterbium trifluoride), and mixed oxidesFiller content: 75–77% by wt., 53–55% by vol.
Filtek Z350 XT (control)3M ESPE, St. Paul, MN, USDMonomer matrix: Bis-GMA, UDMA, TEGDMA, and bis-EMAFiller: Combination of non-agglomerated/non aggregated 20-nm silica filler, non-agglomerated/non-aggregated 4–11-nmzirconia filler, and aggregated zirconia/silica cluster filler (consisting of 20-nm silica and 4–11-nm zirconia particles). The inorganic filler loading is about 72.5% by weight (55.6% by volume).
Sof-Lex3M ESPE, St. Paul, MN, USDExtra-thin contouring and polishing discs; aluminum oxide discs (coarse, 92–98 μm; medium, 25–29 μm; fine, 16–21 μm; and superfine, 2–5 μm)
Restorative Materials and Polishing Systems

Translucency

To measure the translucency, 20 samples of each composite were prepared, of which 10 samples were light-cured with high intensity and the other 10 underwent low-intensity light-curing. Subsequently, the specimens were stored in distilled water for 24 h at 37°C in a dark chamber. The translucency of the specimens fabricated to the recommended thickness (4 mm) using the two different light cure irradiation protocols was measured with a spectrophotometer (color eye 7000 A, Model C6; GretagMacbeth, New Windsor, NY, USA) according to the CIELAB color scale relative to the standard illuminant D65 against a white background (L* = 93.26, a* = −0.61, b* = 2.09) and black background (L* = 2.93, a* = 0.38 and b* = −0.34). The black standard was a matt black plate covered with black velvet, and the white standard was calibrating blocks (white and black) used according to the manufacturer’s recommendation. Each specimen underwent measurements three times, after which the average value was determined.

Calculation of TP

The TP values were determined by calculating the color difference between readings over the black and white backgrounds for the same specimen, using the following formula: TP = [(LB− LW)2+ (aB− aW)2+ (bB− bW)2]1/2 The subscripts “B” and “W” refer to the color coordinates over black and white backgrounds, respectively.

Gloss

A total of 20 samples were obtained from each composite, of which 10 samples were light-cured with high intensity while the other 10 underwent low-intensity light-curing. The specimens were then finished and polished using a series of Sof-Lex discs for 30 s (3M ESPE, St. Paul, USA). Specimens were stored in distilled water for 24 h at 37°C in a dark chamber. The surface gloss of each specimen was measured using a gloss meter (Novo-Curve Gloss meter, East Sussex, UK) with the light source and detector both set at 60° to normal. Before measurement, the gloss meter was calibrated to a standard gloss board (Gs (60°) = 100.4). Two measurements were obtained for each specimen, and the average value was determined.

Statistical Analysis

Data were expressed as mean and standard deviation (SD) and analyzed using SPSS software (version 22.0; IBM SPSS, Armonk, NY, USA). The results were first tested for normality using the Shapiro–Wilk test. The findings were then analyzed using two-way analysis of variance (ANOVA) followed by an independent t-test and one-way ANOVA. However, if one-way ANOVA showed that at least one of the materials was significantly different from the others, multiple comparison tests like Tukey’s or Scheffe’s post hoc test were used to determine the significant differences between the materials and curing light intensities. All tests were performed at a significance level of P < 0.05.

Results

A significant effect was associated with the type of RBC (F = 196.192, p < 0.0001). However, the curing light intensity (F = 0.025, p < 0.875) and the interaction of RBC with the curing light intensity (F = 1.633, p < 0.189) did not show significance (see Table 2 for the two-way ANOVA results). With the high-intensity curing light, the TP value for Reveal HD was the highest (7.688 ± 0.861), followed by Filtek z350 (5.533 ± 0.445), Tetric N-Ceram (3.702 ± 1.176), and Filtek One (2.238 ± 0.591) (one-way ANOVA results of the materials for each curing light intensity are listed in Table 3). The multiple comparison test (Tukey) showed a significant difference among the materials (p < 0.0001 for the F-test).
Table 2

Two-Way ANOVA for Curing Light Intensity and Material for Translucency Parameter (TP) Values

SourceType III Sum-of-SquaresdfMean SquareF Ratiop value
Curing light intensity0.01510.0150.0250.875
RBC345.1783115.059196.1920.0001
Curing light intensity x RBC2.87310.9581.6330.189
Error42.225720.586
Total2236.64280
Corrected total390.29179

Abbreviation: RBC, resin-based composite.

Table 3

One-Way ANOVA and Multiple Comparison Test (Tukey) for Translucency Parameter (TP) Values

Curing Light IntensityRBC MaterialMean TP ValueStandard deviationF-Test p-value95% Confidence Interval for MeanMultiple Comparison Test (Tukey)
Lower BoundUpper BoundFiltek Z350Filtek OneTetricN-CeramRevealHD
HighFiltek Z3505.5330.4450.0005.2155.8521
Filtek One2.2380.5911.8152.6610.0001
Tetric N-Ceram3.7021.1762.8614.5430.0030.0171
Reveal HD7.6880.8617.0728.3040.0000.0000.0001
LowFiltek Z3505.6560.4330.0085.3465.9661
Filtek One1.7500.3761.4812.0190.0001
Tetric N-Ceram4.2651.0003.5504.9800.0070.0001
Reveal HD7.6000.8327.0048.1950.0000.0000.0001
Two-Way ANOVA for Curing Light Intensity and Material for Translucency Parameter (TP) Values Abbreviation: RBC, resin-based composite. One-Way ANOVA and Multiple Comparison Test (Tukey) for Translucency Parameter (TP) Values With the low-intensity curing light, Reveal HD again showed the highest TP value (7.600 ± 0.832), followed by Filtek z350 (5.656 ± 0.433), Tetric N-Ceram (4.265 ± 1.00), and Filtek One (1.750 ± 0.376). The Tukey multiple comparison test also showed a significant difference between the materials (p < 0.008 with the F-test). Figure 1 presents the effect of curing light intensity on each material.
Figure 1

The effect of curing light intensity on translucency parameter (TP) values.

The effect of curing light intensity on translucency parameter (TP) values. Filtek One was the only material that exhibited a significant difference between different curing light intensities. With the high-intensity curing light, Filtek One exhibited a greater TP value (2.238 ± 0.591) than that achieved with the low-intensity curing light (1.750 ± 0.376) (p < 0.041). Two-way ANOVA (Table 4) indicated a significant effect associated with the type of RBC (F = 6.855, P < 0.000) and a significant interaction of the curing light with RBCs (F = 4.018, P < 0.011). However, the curing light intensity (F = 0.244, p < 0.623) did not show a significant effect.
Table 4

Two-Way ANOVA for the Gloss Values

SourceType III Sum-of-SquaresdfMean SquareF-Ratiop
Curing light intensity27.474127.4740.2440.623
RBC2312.8483770.9496.8550.000
Curing light intensity x RBC1355.6223451.8744.0180.011
Error809772112.464
Total16437280
Corrected Total11793.3979
Two-Way ANOVA for the Gloss Values The gloss values of the RBCs were compared at low and high curing light intensities, and the gloss value of 100.4 obtained with a glass board was considered as the reference value. Thus, the shinier a surface was, the closer the value will be to 100%. The results of this analysis are listed in Table 5. With the high-intensity curing light, Tetric N-Ceram (49.100 ± 8.548) showed the highest gloss value among all the materials, followed by Filtek z350 (46.382 ± 11.223), Filtek One (45.630 ± 11.223), and Reveal HD (35.920 ± 9.878). The gloss values of RBCs under high-intensity irradiation were not significantly different (p < 0.136 for the F-test).
Table 5

One-Way ANOVA and Multiple Comparison Test (Tukey) for the Gloss Values

Curing Light IntensityRBC MaterialMean Gloss ValueStd. DeviationF-Test p-value95% Confidence Interval for MeanMultiple Comparison Test (Tukey)
Lower BoundUpper BoundFiltek Z350Filtek OneTetricN-CeramReveal HD
High intensityFiltek Z35046.38211.2230.13638.35354.4101
Filtek One45.63019.37031.77359.4870.9991
Tetric N-Ceram49.1008.54842.98555.2150.9650.9321
Reveal HD35.9209.87828.85442.9860.2880.3510.1321
Low intensityFiltek Z35045.8336.2390.00041.37050.2961
Filtek One55.27010.10648.04162.4990.0391
Tetric N-Ceram35.5606.53330.88740.2330.0220.0001
Reveal HD35.6806.64830.92440.4360.0240.0001.0001
One-Way ANOVA and Multiple Comparison Test (Tukey) for the Gloss Values However, with the low-intensity curing light, Filtek One showed the highest gloss value (55.270 ± 10.106), followed by Filtek Z350 (45.833 ± 6.239), Reveal HD (35.680 ± 6.648), and Tetric N-Ceram (35.560 ± 6.533). There was a significant difference between the materials (p < 0.00 for the F-test), while the multiple comparison test showed significant differences between all materials except Tetric N-Ceram and Reveal HD. In addition, Tetric N-Ceram was the only material affected by the curing light intensity, with a high light intensity yielding a higher gloss value (49.100 ± 8.548) than that observed with a low light intensity (35.560 ± 6.533). The effect of curing light intensity on surface gloss of each RBC is presented in Figure 2.
Figure 2

The effect of curing light intensity on surface gloss.

The effect of curing light intensity on surface gloss.

Discussion

In this study, the translucency and surface gloss of bulk-fill RBCs were evaluated using two different curing light intensities. The results of this study showed that the curing light intensities had no effect on the translucency and surface gloss, except in the case of Filtek One, which showed a higher TP value with high-intensity curing, and Tetric N-Ceram, which showed a higher gloss value with high-intensity curing. A spectrophotometer was used in this study to determine the material translucency, and Reveal HD showed the highest TP value. This finding could be explained by the filler-resin refractive index of the material. According to the manufacturer’s literature, Reveal HD is prepared using an HD filler technology, which means that light can be effectively refracted and distributed through the material. Conversely, Filtek One showed the lowest TP, which can be attributed to the interaction of its filler with the resin matrix. This is described by the manufacturer as Smart Contrast Ratio management technology and is claimed to increase the opacity without reducing the depth of cure. Our results showed Tetric N-Ceram to be superior in terms of opacity. This material is claimed to have a new Aessencio filler technology but, whatever the details, it proved to be superior in terms of opacity when measured experimentally. The Filtek One bulk fill was affected by the curing light intensity, with the higher light intensity resulting in a higher TP value. This was an agreement with the results of a study by Mondelli et al17 which evaluated the changes in optical appearance in resin-based composites after light curing. The material color showed a significant change after light curing; this can be explained by the change in translucency while the material is being cured, a process called photobleaching; after light activation, photoinitiators break their chromophore groups, which diminishes their yellow color.18 Another study by Sidhu et al19 evaluated the changes in translucency caused by light-curing RBCs. They concluded that light-curing resin-based composite shows fewer changes in TP during light curing. The increased TP value could be due to the change in difference between resin matrix and that of the refractive index of the glass filler during light curing. At a thickness of 2 mm, Filtek Z350 showed a lower TP value than Reveal HD and a higher TP value than Tetric N-Ceram and Filtek One. The relationship between resin composite thickness and its translucency is a topic of debate. Kim et al20 evaluated the effect of resin thickness on RBC’s optical properties. They found that the TP decreased with an increase in the thickness. The results of their study were in agreement with those of a study by Arimoto et al,11 and another study by Ardu et al,21 which also reported a reduction in translucency with an increase in the thickness of RBCs. Light transmission through a material with greater thickness will result in more scattering, which decreases the translucency. In our study, the highest TP values were obtained with a 4-mm-thick Reveal HD specimen; this was an agreement with the study by Son et al,22 who compared the translucency of bulk-fill and conventional composites and found that bulk-fill composites had a higher translucency, they found that the lower the filler volume the higher the TP values. Surface gloss or smoothness is one of the major esthetic features of dental biomaterials.23 Several factors affect the surface gloss, such as the restorative material composition and the finishing and polishing system used.10 Lopes et al evaluated the surface gloss using different polishing techniques and different resin-based composites. The results of their study indicated that both the finishing technique and the restorative materials influenced the surface gloss.24 The finishing and polishing procedure is an important step influencing the outcomes of the composite restoration. Many finishing and polishing materials are available on the market, such as aluminum discs, diamond burs, and rubber cups.25 In our study, finishing and polishing were performed by using a series of Sof-Lex discs. Several studies recommended using the aluminum discs, which they claimed was the best finishing and polishing protocol to be used.25–27 In the present study, Filtek One showed the highest gloss value among all the materials when using a low-intensity light cure; this could be explained by the nanofiller technology. Gerhardt et al28 found that the filler size affected the surface gloss. They concluded that a small filler size resulted in a higher surface gloss. Tetric n-Ceram was the only material effected by the curing light intensity, with a high curing light intensity resulting in a higher gloss value. However, Filtek One bulk fill, Filtek z350, and Reveal HD bulk fill were not affected by the curing light intensity. These findings were in agreement with the results of a study by Lassila et al,29 which evaluated the effect of a high curing light intensity with different curing times on the surface gloss. They concluded that the surface gloss was not affected by the different light-curing protocols used. Another study by Andrade et al30 also showed no effect of the LCU on the surface gloss of conventional RBCs. The hypothesis in this study was partially accepted since the rest of the materials were not significantly affected by the curing light intensity. The results of this study emphasize the importance of curing light intensity and material selection. However, more longitudinal studies are needed to support the use of bulk-fill RBCs in clinical practice.

Conclusions

The curing light intensity affected the translucency of Filtek One bulk fill, with a high intensity resulting in a higher TP value. Similarly, Tetric N-Ceram showed a higher gloss value with high-intensity light-curing compared to that with low-intensity light-curing. However, the curing light intensity did not affect the rest of the tested materials.
  26 in total

1.  Translucency, opalescence and light transmission characteristics of light-cured resin composites.

Authors:  Ayako Arimoto; Masatoshi Nakajima; Keiichi Hosaka; Kozo Nishimura; Masaomi Ikeda; Richard M Foxton; Junji Tagami
Journal:  Dent Mater       Date:  2010-08-07       Impact factor: 5.304

2.  Changes in gloss after simulated generalized wear of composite resins.

Authors:  Yong-Keun Lee; Huan Lu; Makoto Oguri; John M Powers
Journal:  J Prosthet Dent       Date:  2005-10       Impact factor: 3.426

3.  Change of color and translucency by light curing in resin composites.

Authors:  Sharanbir K Sidhu; Takatsumi Ikeda; Yo Omata; Megumi Fujita; Hidehiko Sano
Journal:  Oper Dent       Date:  2006 Sep-Oct       Impact factor: 2.440

4.  Resin composite thickness' influence on L*a*b* coordinates and translucency.

Authors:  S Ardu; I Rossier; E di Bella; I Krejci; D Dietschi
Journal:  Clin Oral Investig       Date:  2018-08-24       Impact factor: 3.573

5.  Evaluation of the surface hardness, roughness, gloss and color of composites after different finishing/polishing treatments and thermocycling using a multitechnique approach.

Authors:  Kanşad Pala; Neslihan Tekçe; Safa Tuncer; Merve Efe Serim; Mustafa Demirci
Journal:  Dent Mater J       Date:  2016       Impact factor: 2.102

6.  How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites?

Authors:  Sung-Ae Son; Jeong-Kil Park; Deog-Gyu Seo; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Clin Oral Investig       Date:  2016-07-31       Impact factor: 3.573

7.  Translucency parameter of colorants for maxillofacial prostheses.

Authors:  W M Johnston; T Ma; B H Kienle
Journal:  Int J Prosthodont       Date:  1995 Jan-Feb       Impact factor: 1.681

8.  Influence of different light-curing units in surface roughness and gloss of resin composites for bleached teeth after challenges.

Authors:  Karina Carvalho Andrade; Nubia Inocencya Pavesi Pini; Mariana Dias Moda; Fernanda de Souza E Silva Ramos; Paulo Henrique Dos Santos; André Luiz Fraga Briso; Ticiane Cestari Fagundes
Journal:  J Mech Behav Biomed Mater       Date:  2019-10-03

9.  Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials.

Authors:  Norbert Moszner; Urs Karl Fischer; Beate Ganster; Robert Liska; Volker Rheinberger
Journal:  Dent Mater       Date:  2007-12-21       Impact factor: 5.304

10.  Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites.

Authors:  Eun-Ha Kim; Kyoung-Hwa Jung; Sung-Ae Son; Bock Hur; Yong-Hoon Kwon; Jeong-Kil Park
Journal:  Restor Dent Endod       Date:  2015-01-13
View more
  1 in total

1.  The effect of bleaching applications on stained bulk-fill resin composites.

Authors:  Ayse Tugba Erturk-Avunduk; Esra Cengiz-Yanardag; Izgen Karakaya
Journal:  BMC Oral Health       Date:  2022-09-10       Impact factor: 3.747

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.