Derivation of Respiratory Metrics in Health and Asthma.

Joseph Prinable1,2, Peter Jones3, David Boland3, Alistair McEwan1, Cindy Thamrin2.   

Abstract

The ability to continuously monitor breathing metrics may have indications for general health as well as respiratory conditions such as asthma. However, few studies have focused on breathing due to a lack of available wearable technologies. To examine the performance of two machine learning algorithms in extracting breathing metrics from a finger-based pulse oximeter, which is amenable to long-term monitoring.
METHODS: Pulse oximetry data were collected from 11 healthy and 11 with asthma subjects who breathed at a range of controlled respiratory rates. U-shaped network (U-Net) and Long Short-Term Memory (LSTM) algorithms were applied to the data, and results compared against breathing metrics derived from respiratory inductance plethysmography measured simultaneously as a reference.
RESULTS: The LSTM vs. U-Net model provided breathing metrics which were strongly correlated with those from the reference signal (all p < 0.001, except for inspiratory: expiratory ratio). The following absolute mean bias (95% confidence interval) values were observed (in seconds): inspiration time 0.01(-2.31, 2.34) vs. -0.02(-2.19, 2.16), expiration time -0.19(-2.35, 1.98) vs. -0.24(-2.36, 1.89), and inter-breath intervals -0.19(-2.73, 2.35) vs. -0.25(2.76, 2.26). The inspiratory:expiratory ratios were -0.14(-1.43, 1.16) vs. -0.14(-1.42, 1.13). Respiratory rate (breaths per minute) values were 0.22(-2.51, 2.96) vs. 0.29(-2.54, 3.11). While percentage bias was low, the 95% limits of agreement was high (~35% for respiratory rate).
CONCLUSION: Both machine learning models show strong correlation and good comparability with reference, with low bias though wide variability for deriving breathing metrics in asthma and health cohorts. Future efforts should focus on improvement of performance of these models, e.g., by increasing the size of the training dataset at the lower breathing rates.

Entities:  

Keywords:  LSTM; U-Net; asthma; machine learning; respiratory monitoring

Mesh:

Year:  2020        PMID: 33322776      PMCID: PMC7764376          DOI: 10.3390/s20247134

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  17 in total

1.  Measuring asthma control in group studies: do we need airway calibre and rescue beta2-agonist use?

Authors:  E F Juniper; P M O'Byrne; J N Roberts
Journal:  Respir Med       Date:  2001-05       Impact factor: 3.415

2.  Respiratory effort from the photoplethysmogram.

Authors:  Paul S Addison
Journal:  Med Eng Phys       Date:  2017-01-23       Impact factor: 2.242

3.  Multiparameter respiratory rate estimation from the photoplethysmogram.

Authors:  Walter Karlen; Srinivas Raman; J Mark Ansermino; Guy A Dumont
Journal:  IEEE Trans Biomed Eng       Date:  2013-02-08       Impact factor: 4.538

4.  The pattern of breathing in acute severe asthma.

Authors:  D R Hillman; L Prentice; K E Finucane
Journal:  Am Rev Respir Dis       Date:  1986-04

5.  RespNet: A deep learning model for extraction of respiration from photoplethysmogram.

Authors:  Vignesh Ravichandran; Balamurali Murugesan; Vaishali Balakarthikeyan; Keerthi Ram; S P Preejith; Jayaraj Joseph; Mohanasankar Sivaprakasam
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

6.  Toward Accurate Extraction of Respiratory Frequency From the Photoplethysmogram: Effect of Measurement Site.

Authors:  Vera Hartmann; Haipeng Liu; Fei Chen; Wentao Hong; Stephen Hughes; Dingchang Zheng
Journal:  Front Physiol       Date:  2019-06-18       Impact factor: 4.566

7.  Classification of Asthma Based on Nonlinear Analysis of Breathing Pattern.

Authors:  Mohammad Reza Raoufy; Tara Ghafari; Reza Darooei; Milad Nazari; Seyed Alireza Mahdaviani; Ali Reza Eslaminejad; Mehdi Almasnia; Shahriar Gharibzadeh; Ali R Mani; Sohrab Hajizadeh
Journal:  PLoS One       Date:  2016-01-29       Impact factor: 3.240

8.  An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram.

Authors:  Peter H Charlton; Timothy Bonnici; Lionel Tarassenko; David A Clifton; Richard Beale; Peter J Watkinson
Journal:  Physiol Meas       Date:  2016-03-30       Impact factor: 2.833

9.  Extracting Instantaneous Respiratory Rate From Multiple Photoplethysmogram Respiratory-Induced Variations.

Authors:  Parastoo Dehkordi; Ainara Garde; Behnam Molavi; J Mark Ansermino; Guy A Dumont
Journal:  Front Physiol       Date:  2018-07-18       Impact factor: 4.566

10.  Photoplethysmographic determination of the respiratory rate in acutely ill patients: validation of a new algorithm and implementation into a biomedical device.

Authors:  Erwan L'Her; Quang-Thang N'Guyen; Victoire Pateau; Laetitia Bodenes; François Lellouche
Journal:  Ann Intensive Care       Date:  2019-01-21       Impact factor: 6.925

View more