Literature DB >> 33322315

New Contact Sensorization Smart System for IoT e-Health Applications Based on IBC IEEE 802.15.6 Communications.

David Hernández1, Rafael Ors1, Juan V Capella1, Alberto Bonastre1, José C Campelo1.   

Abstract

This paper proposes and demonstrates the capabilities of a new sensorization system that monitors skin contact between two persons. Based on the intrabody communication standard (802.15.6), the new system allows for interbody communication, through the transmission of messages between different persons through the skin when they are touching. The system not only detects if there has been contact between two persons but, as a novelty, is also able to identify the elements that have been in contact. This sensor will be applied to analyze and monitor good follow-up of hand hygiene practice in health care, following the "World Health Organization Guidelines on Hand Hygiene in Health Care". This guide proposes specific recommendations to improve hygiene practices and reduce the transmission of pathogenic microorganisms between patients and health-care workers (HCW). The transmission of nosocomial infections due to improper hand hygiene could be reduced with the aid of a monitoring system that would prevent HCWs from violating the protocol. The cutting-edge sensor proposed in this paper is a crucial innovation for the development of this automated hand hygiene monitoring system (AHHMS).

Entities:  

Keywords:  IEEE 802.15.6; interbody communications; intrabody communications

Mesh:

Year:  2020        PMID: 33322315      PMCID: PMC7764060          DOI: 10.3390/s20247097

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  13 in total

1.  [Compliance with hand hygiene guidelines and determinants of compliance].

Authors:  José Sánchez-Payá; M Dolores Galicia-García; Rebeca M Gracia-Rodríguez; Concepción García-González; Marina Fuster-Pérez; Nieves López-Fresneña; Félix Avendaño-Corcoles; Antonio González-Torga
Journal:  Enferm Infecc Microbiol Clin       Date:  2007 Jun-Jul       Impact factor: 1.731

2.  Equation environment coupling and interference on the electric-field intrabody communication channel.

Authors:  Ruoyu Xu; Wai Chiu Ng; Hongjie Zhu; Hengying Shan; Jie Yuan
Journal:  IEEE Trans Biomed Eng       Date:  2012-05-02       Impact factor: 4.538

3.  Merging video coaching and an anthropologic approach to understand health care provider behavior toward hand hygiene protocols.

Authors:  Sophia Boudjema; Clément Tarantini; Patrick Peretti-Watel; Philippe Brouqui
Journal:  Am J Infect Control       Date:  2017-01-26       Impact factor: 2.918

4.  Monitoring the hand hygiene compliance of health care workers in a general intensive care unit: Use of continuous closed circle television versus overt observation.

Authors:  Evgeni Brotfain; Ilana Livshiz-Riven; Alexander Gushansky; Alexander Erblat; Leonid Koyfman; Tomer Ziv; Lisa Saidel-Odes; Moti Klein; Abraham Borer
Journal:  Am J Infect Control       Date:  2017-05-04       Impact factor: 2.918

5.  Replicating changes in hand hygiene in a surgical intensive care unit with remote video auditing and feedback.

Authors:  Donna Armellino; Manish Trivedi; Isabel Law; Narendra Singh; Mary Ellen Schilling; Erfan Hussain; Bruce Farber
Journal:  Am J Infect Control       Date:  2013-03-13       Impact factor: 2.918

6.  Automated measures of hand hygiene compliance among healthcare workers using ultrasound: validation and a randomized controlled trial.

Authors:  Dale A Fisher; Theresa Seetoh; Helen Oh May-Lin; Sivakumar Viswanathan; Yanling Toh; Wong Chiang Yin; Loh Siw Eng; Tan Shire Yang; Steve Schiefen; Minkyu Je; Ruey Feng Peh; Fiona Wei Ling Loke; Michael Dempsey
Journal:  Infect Control Hosp Epidemiol       Date:  2013-07-31       Impact factor: 3.254

7.  Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis.

Authors:  Yuhwai Tseng; Chauchin Su; Yingchieh Ho
Journal:  PLoS One       Date:  2016-02-11       Impact factor: 3.240

8.  The Modeling and Simulation of the Galvanic Coupling Intra-Body Communication via Handshake Channel.

Authors:  Maoyuan Li; Yong Song; Wansong Li; Guangfa Wang; Tianpeng Bu; Yufei Zhao; Qun Hao
Journal:  Sensors (Basel)       Date:  2017-04-14       Impact factor: 3.576

9.  "First-person view" of pathogen transmission and hand hygiene - use of a new head-mounted video capture and coding tool.

Authors:  Lauren Clack; Manuela Scotoni; Aline Wolfensberger; Hugo Sax
Journal:  Antimicrob Resist Infect Control       Date:  2017-10-30       Impact factor: 4.887

10.  Modeling and Characterization of Capacitive Coupling Intrabody Communication in an In-Vehicle Scenario.

Authors:  Yuan Xu; Zhonghua Huang; Shize Yang; Zhiqi Wang; Bing Yang; Yinlin Li
Journal:  Sensors (Basel)       Date:  2019-10-04       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.