Literature DB >> 33316958

Influence of Preparation Design, Marginal Gingiva Location, and Tooth Morphology on the Accuracy of Digital Impressions for Full-Crown Restorations: An In Vitro Investigation.

Selina A Bernauer1, Johannes Müller2, Nicola U Zitzmann1, Tim Joda1.   

Abstract

(1) Background: Intraoral optical scanning (IOS) has gained increased importance in prosthodontics. The aim of this in vitro study was to analyze the IOS accuracy for treatment with full crowns, considering possible influencing factors. (2)
Methods: Two tooth morphologies, each with four different finish-line designs for tooth preparation and epi- or supragingival locations, were digitally designed, 3D-printed, and post-processed for 16 sample abutment teeth. Specimens were digitized using a laboratory scanner to generate reference STLs (Standard Tessellation Language), and were secondary-scanned with two IOS systems five times each in a complete-arch model scenario (Trios 3 Pod, Primescan AC). For accuracy, a best-fit algorithm (Final Surface) was used to analyze deviations of the abutment teeth based on 160 IOS-STLs compared to the reference STLs (16 preparations × 2 IOS-systems × 5 scans per tooth). (3)
Results: Analysis revealed homogenous findings with high accuracy for intra- and inter-group comparisons for both IOS systems, with mean values of 80% quantiles from 20 ± 2 μm to 50 ± 5 μm. Supragingival finishing lines demonstrated significantly higher accuracy than epigingival margins when comparing each preparation (p < 0.05), whereas tangential preparations exhibited similar results independent of the gingival location. Morphology of anterior versus posterior teeth showed slightly better results in favor of molars in combination with shoulder preparations only. (4)
Conclusion: The clinical challenge for the treatment with full crowns following digital impressions is the location of the prospective restoration margin related to the distance to the gingiva. However, the overall accuracy for all abutment teeth was very high; thus, the factors tested are unlikely to have a strong clinical impact.

Entities:  

Keywords:  digital dentistry; fixed prosthodontics; full crown; intraoral optical scanning (IOS); tooth preparation

Year:  2020        PMID: 33316958     DOI: 10.3390/jcm9123984

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  2 in total

1.  A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners.

Authors:  Irina Karakas-Stupar; Nicola Ursula Zitzmann; Tim Joda
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

2.  Computer Aided Design Modelling and Finite Element Analysis of Premolar Proximal Cavities Restored with Resin Composites.

Authors:  Amanda Guedes Nogueira Matuda; Marcos Paulo Motta Silveira; Guilherme Schmitt de Andrade; Amanda Maria de Oliveira Dal Piva; João Paulo Mendes Tribst; Alexandre Luiz Souto Borges; Luca Testarelli; Gabriella Mosca; Pietro Ausiello
Journal:  Materials (Basel)       Date:  2021-05-01       Impact factor: 3.623

  2 in total