Evaluation of factors affecting the visualization of dye after transbronchial dye injection: an animal experiment.

Jung Seop Eom1, Hyo Yeong Ahn2, Yeong Dae Kim2, Insu Kim3, Hee Yun Seol4.   

Abstract

BACKGROUND: Since peripheral lung lesions can be frequently visualized on computed tomography (CT), various methods of localization for thoracoscopic surgery have been developed. In the case of transbronchial dye injection (TDI), there can be difficulties with dye visualization through the thoracoscope depending on early disappearance of the dye due to diffusion before field exposure. Herein, we performed an animal experiment to determine the appropriate dye amount and the duration of visualization.
METHODS: Twelve pigs were experimented as following four groups (n=3): group 1 received 0.6 mL of dye; group 2 as 0.8 mL; and group 3 as 1.0 mL, all followed by 2.0 mL of air injection and group 4, with 1.0 mL of dye followed no air injection to evaluate the utility of air injection. The detection, the peak time, the wash-out time were measured.
RESULTS: The mean detection times, the peak time, and the mean wash-out times for 0.6, 0.8, and 1.0 mL of dye were not significantly different (P=0.195, 0.092, 0.06). However, regardless of the injected amount, it usually lasts in 2 hours. Comparing with non-air injection group, the peak time and wash-out time were statistically significantly different in injected group; P=0.07 and 0.001.
CONCLUSIONS: The marking could be identified clearly at about 2 hours after TDI regardless of the amount of indigo carmine injected. However, in cases with longer duration to exposure, especially in cases with severe adhesions, it might be necessary to discover the mixture of dye which will last longer for visualization of lung nodules. 2020 Annals of Translational Medicine. All rights reserved.

Entities:  

Keywords:  Transbronchial injection; detection; lung nodule; marker; visualization

Year:  2020        PMID: 33313170      PMCID: PMC7723521          DOI: 10.21037/atm-20-1695

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


Introduction

Since peripheral lung lesions located more than 1 cm deep within the visceral pleura can be frequently visualized on computed tomography (CT), various methods of localization for thoracoscopic surgery have been developed, such as transthoracic needle localization or dye injection through bronchoscopy (1-7). With the methods that use transthoracic percutaneous localization, the occurrence of post-procedural complications, such as pneumothorax or bleeding, is possible (1,3,6). In the case of transbronchial dye injection (TDI) via bronchoscopy, the aforementioned complications do not occur based on several articles (7,8); however, there can be difficulties with dye visualization through the thoracoscope depending on early disappearance of the dye due to diffusion before field exposure (1,8-10). Herein, we performed an animal experiment to determine how much dye is needed for visualization of peripheral lung lesions, how long the dye lasts, when the dye disappears, and whether air injection following dye injection is necessary. We present the following study in accordance with the ARRIVE reporting checklist (available at http://dx.doi.org/10.21037/atm-20-1695).

Methods

Animal model and study groups

Twelve live female farm pigs were used to identify the appropriate amount of indigo carmine needed for localization of peripheral lung lesions using a bronchoscope. The mean age of the pigs was 11.2±1.2 (range, 10–13) weeks, and weight was 39.3±1 (range, 38.4–41.1) kg. Experiments were performed under a project license (No. PNUYH-2018-059) granted by the Institutional Animal Care and Use Committee of Pusan National University Yangsan Hospital in compliance with Pusan national university guidelines for the care and use of animals. Nine pigs were categorized into three groups based on the amount of dye injected: group 1 received 0.6 mL of dye (n=3); group 2 received 0.8 mL of dye (n=3); and group 3 received 1.0 mL of dye (n=3), all followed by 2.0 ml of air injection. Another three pigs were included in group 4, which received 1.0 mL of dye followed by no air injection to evaluate the utility of air injection. Generally, TDI was clinically conducted to detect peripheral lung lesion within 2 cm from visceral pleura, the location of injection was targeted to the area within 1 cm from visceral pleura nearby the lung lesion for the indigo carmine to be easily detected on visceral pleura.

Animal experiment

All procedures were performed with the pigs under general anesthesia using an intravenous injection of propofol (4–12 mg/kg/h) and intramuscular injection of tiletamine and zolazepam (4.4–6.6 mg/kg), and meloxicam (0.4 mg/kg). Orotracheal intubation was performed initially, followed by tracheostomy. Under supine position, the predicted place for the thoracoscopic port was generally incised at the sixth mid-axillary line and seventh posterior axillary line of the intercostal space before bronchoscopic dye administration, and dissected before reaching the parietal pleura, which was cautiously not punctured to prevent pneumothorax. Before bronchoscopy, a guide sheath (K-201; Olympus, Tokyo, Japan) and biopsy forceps were prepared so the surgeon could approach the peripheral region of the porcine lung. The bronchoscope (BF-260; Olympus, Tokyo, Japan) was advanced as far as possible under direct vision to superior segment of right lower lobe; thereafter, guide sheath-covered biopsy forceps were introduced through the working channel of the bronchoscope under fluoroscopic guidance. When the guide sheath-covered biopsy forceps reached within 1cm from visceral pleura under fluoroscopic guidance, the biopsy forceps were removed, while the guide sheath was kept in place for subsequent administration of indigo carmine (Daiichi-Sankyo Inc., Tokyo, Japan). To maintain one-lung ventilation during thoracoscopic inspection, the endotracheal tube was inserted into the tracheostomy orifice and placed in the left main bronchus under bronchoscopic guidance (BF-P160; Olympus). Just after TDI, the pigs were placed in lateral decubitus position and followed by inserting two ports. The thoracoscope was advanced to examine the dyed area of the visceral pleura.

Definitions of the measured times

The detection time was defined as when the dyed area of the visceral pleura was identified for the first time. The peak time was defined as when the dyed area was fully extended. The instrument was used for measuring, for example, fully opening of the tip clinch was measured as 2.5 cm. The wash-out time was defined as when the dyed extent of the visceral pleura became less than two-third of the peak time.

Statistical analysis

The t-test and one-way analysis of variance were used to compare data between the study groups for statistical significance. The data are expressed as the mean ± standard deviation (range). A P value <0.05 was considered as statistically significant. All data analyses were conducted using SPSS Statistics software, version 24.0 (IBM, Corp., Armonk, NY, USA).

Results

The mean age of the pigs was 11.2±1.2 (range, 10–13) weeks, and weight was 39.3±1 (range, 38.4–41.1) kg. TDI was performed in 12 pigs (three pigs in each group), and the most common injected site was the superior segment. The mean bronchoscopy time was 2.4±0.48 (range, 1.8–3.4) minutes, and fluoroscopy time was 2.13±0.72 (range, 1.4–3.7) minutes. All the pigs were alive and had not shown the unstable vital sign during the procedure, and the procedure was successfully performed. The mean detection times for 0.6, 0.8, and 1 mL of dye were 4.53±0.59 (range, 4.1–5.2), 2.67±1.48 (range, 1.4–4.3), and 2.2±1.65 (range, 1.2–4.1) minutes, respectively, which were not significantly different (P=0.195) (). The mean peak times for 0.6, 0.8, and 1 mL of dye were 28.07±5.12 (range, 23.2–33.4), 34.13±3.26 (range, 30.4–36.4), and 42.97±10.86 (range, 35.3–55.4) minutes, respectively, which were not significantly different (P=0.092) (). The mean wash-out times for 0.6, 0.8, and 1 mL of dye were 117.23±68.61 (range, 75.1–196.4), 134.07±15.72 (range, 119.3–150.6), and 134.67±74.44 (range, 85.4–220.3) minutes, respectively, which were not significantly different (P=0.06) () ().
Figure 1

Thoracoscopic images showing changes in the dye extent over time depending on the amount of dye injected and the use of air injection.

Table 1

Detection time, peak time, and wash-out time depending on the amount of dye injected

Amount of dye injected (mL)P value
0.60.81
Detection time (minutes)4.53±0.592.67±1.482.2±1.650.195
Peak time (minutes)28.07±5.1234.13±3.2642.97±10.860.092
Wash-out time (minutes)117.23±68.61134.07±15.72134.67±74.440.06
Thoracoscopic images showing changes in the dye extent over time depending on the amount of dye injected and the use of air injection. In group 4, the mean detection time, mean peak time, and mean wash-out time were 3.27±1.90 (range, 1.4–5.2), 12.1±1.6 (range, 10.4–13.6), and 46.23±10.58 (range, 38.1–58.2) minutes, respectively. In group 3, those respective times were 2.2±1.65 (range, 1.2–4.1), 28.07±5.12 (range, 23.2–33.4), and 134.07±15.72 (range, 119.3–150.6) minutes. The peak time and wash-out time were statistically significantly different between groups 3 and 4 (P=0.07 and 0.001, respectively) ().
Table 2

Detection time, peak time, and wash-out time depending on use of air injection

Air injectionP value
NoYes
Detection time (minutes)3.27±1.902.2±1.650.5
Peak time (minutes)12.1±1.628.07±5.120.07
Wash-out time (minutes)46.23±10.58134.07±15.720.001

Measured sizes of the dye extent at the detection time, peak time, and wash-out time

The mean measured sizes of 0.6, 0.8, and 1.0 mL of dye extent at the detection time, peak time, and wash-out time were significantly different (P=0.001, 0.001, and 0.002, respectively) (). The mean measured sizes of 0.6, 0.8, and 1 mL of dye extent at the detection time, peak time, and washed-out time were significantly different between groups 3 and 4 (P=0.003, 0.003, and 0.001, respectively) (, ). The change in the size of the dye extent was significant over time (P<0.001), and the size of the dye extent was significantly different depending on the amount of dye injected (P=0.004). And group 2 has significant difference in detection time, peak time and wash-out time comparing with group 1 (P=0.06, 0.009, 0.011, respectively). The change in the size of dye extent was significantly changed over time in group 4 compared with group 3 (P<0.001), and the size of the dye extent was significantly smaller in group 4 than in group 3 (P<0.001).
Table 3

Measured sizes of the dye extent at the detection time, peak time, and wash-out time depending on the amount of dye injected

Measured size of the dye extent (mm)Amount of dye injected (mL)P value
0.60.81
Detection time5.87±2.0112.56±0.8615.6±1.570.001
Peak time7.3±2.1113.37±0.9616.7±1.370.001
Wash-out time5.1±1.729.76±1.0011.5±0.750.002
Figure 2

Size of the dye extend depending on (A) the amount of dye and time, and (B) use of air injection. (A) The size of the dye extent is significantly different depending on the amount of dye injected; (B) the size of the dye extent is significantly smaller in group 4 (no air injection) (P<0.001), and the size of the dye extent is significantly different depending on air injection.*, Mean time was described under every graph.

Table 4

Measured size of the dye extent at the detection time, peak time, and wash-out time depending on the use of air injection

Measured size of the dye extent (mm)Air injectionP value
NoYes
Detection time7.13±1.6515.60±1.570.003
Peak time9.17±1.4716.70±1.370.003
Wash-out time6.10±0.7511.50±0.750.001
Size of the dye extend depending on (A) the amount of dye and time, and (B) use of air injection. (A) The size of the dye extent is significantly different depending on the amount of dye injected; (B) the size of the dye extent is significantly smaller in group 4 (no air injection) (P<0.001), and the size of the dye extent is significantly different depending on air injection.*, Mean time was described under every graph. In summary, the mean detection times, the mean peak times, and the mean wash-out times for 0.6, 0.8, and 1.0 mL of dye were not significantly different each other. However, between groups 3 and 4, the peak time and wash-out time were statistically significantly different (P=0.003 and 0.001, respectively), which meant the application of air injection might be important to be exposed longer time.

Discussion

Indeterminate pulmonary nodules have been frequently detected since chest CT has been developed. In cases with an increasing number of nodules, therapeutic or diagnostic resection needs to be considered. Although CT-assisted percutaneous marking using lipiodol or wire might be most commonly used for non-palpable nodules located more than 1 cm deep within the visceral pleura, pneumothorax could occur in about 15% of cases, and lipiodol could be spilled into pleural cavity, which might cause pleuritic chest pain and the wire could become dislodged (3,6,10-14). With lipiodol marking, exposure of radiation cannot be avoidable for the patient and operating team (12-14). TDI using indigo carmine might be another option to make small nodules identifiable by direct vision (1,8-10). Clinically, TDI has been frequently performed in these days, which let the risk of complications decreased, such as pneumothorax, hemothorax, and pleuritic chest pain. However, the dye can be easily and rapidly diffused (8-10), making it potentially difficult to identify the nodule as the interval time between TDI and exploration under video-assisted thoracoscopic surgery becomes longer. Especially if a patient has severe adhesion, the injected dye could become diffused and spontaneously resolve during dissection of the adhesion, and multiple areas of hemorrhage or anthracosis mimicking the color of the dye could cause confusion (8,9). In our series, there were no significant differences in the detection time, peak time, and wash-out time among groups with 0.6, 0.8, and 1.0 mL of dye injected. However, in the group without air injection, the detection time was significantly delayed, and the interval time to the peak time and wash-out time was significantly shorter than that in the group with air injection. This finding might explain why remnant dye could be left in the catheter even if the same amount of dye was injected. Since air injection after dye injection enabled the dye to be completely sprayed through the catheter, indigo carmine could be easily identified on the peripheral lung parenchyma. As shown in the results, the marking could be identified clearly at about 2 hours after TDI regardless of the amount of indigo carmine injected. Without air injection, the marking might only last for 1 hour. In our study, the higher the amount of dye injected, the larger the dye extent was visualized, and the dye could be more easily detected in the group with air injection than in the group without air injection group. To compare the difference in size of dye extent among each group, group 2 has significant difference comparing with group 1 (P<0.05) (). Thus, in cases in which (I) 2 hours has passed after injection of (II) less than 0.8 mL of dye or (III) no air injection, visualization of dye might fail during thoracoscopic surgery. Still, this study has some limitations. First, it is a small-sized experiment, which does not have strong statistical power. Second, it is performed by one of experts in bronchoscopic intervention, which means it cannot guarantee same result in case by the other specialist. Third, although the pigs are relatively suited to human based on similarities in their respiratory system, it could be mistranslated to human biology.

Conclusions

TDI might be reliable and efficient for detecting small peripheral lung nodules in cases with more than 0.8 mL of dye injected followed by air injection within 2 hours after dye injection. However, in cases with severe adhesion and anthracotic pigmentation, it makes longer predicted time to lesion exposure or confusing the lesion, and also for emphysema, it could be diffused easily which don’t let the injected area be localized. Therefore, it might be necessary to discover the mixture of dye which will last longer for visualization of lung nodules and distinct from anthracotic pigmentation. The article’s supplementary files as
  14 in total

Review 1.  Novel Methods of Intraoperative Localization and Margin Assessment of Pulmonary Nodules.

Authors:  Jane Keating; Sunil Singhal
Journal:  Semin Thorac Cardiovasc Surg       Date:  2016-02-04

2.  Preoperative Computed Tomography-Guided Pulmonary Lesion Marking in Preparation for Fluoroscopic Wedge Resection-Rates of Success, Complications, and Pathology Outcomes.

Authors:  Babatunde Olaiya; Charles A Gilliland; Seth D Force; Felix G Fernandez; Manu S Sancheti; William C Small
Journal:  Curr Probl Diagn Radiol       Date:  2017-11-06

3.  The Utility of Indigo Carmine and Lipiodol Mixture for Preoperative Pulmonary Nodule Localization before Video-Assisted Thoracic Surgery.

Authors:  Takaaki Hasegawa; Hiroaki Kuroda; Yozo Sato; Keitaro Matsuo; Shozo Sakata; Hideki Yashiro; Noriaki Sakakura; Tetsuya Mizuno; Takaaki Arimura; Hidekazu Yamaura; Shinichi Murata; Yugo Imai; Yukinori Sakao; Yoshitaka Inaba
Journal:  J Vasc Interv Radiol       Date:  2019-03       Impact factor: 3.464

Review 4.  Comparative Effectiveness and Safety of Preoperative Lung Localization for Pulmonary Nodules: A Systematic Review and Meta-analysis.

Authors:  Chul Hwan Park; Kyunghwa Han; Jin Hur; Sang Min Lee; Ji Won Lee; Sung Ho Hwang; Jae Seung Seo; Kye Ho Lee; Woocheol Kwon; Tae Hoon Kim; Byoung Wook Choi
Journal:  Chest       Date:  2016-10-04       Impact factor: 9.410

5.  CT fluoroscopy-guided bronchoscopic dye marking for resection of small peripheral pulmonary nodules.

Authors:  Masahiro Endo; Yoshikazu Kotani; Miyako Satouchi; Yoshiki Takada; Toshihiko Sakamoto; Noriaki Tsubota; Hiroyoshi Furukawa
Journal:  Chest       Date:  2004-05       Impact factor: 9.410

6.  Fluoroscopy-assisted thoracoscopic resection of pulmonary nodules after computed tomography--guided bronchoscopic metallic coil marking.

Authors:  Takanori Miyoshi; Kazuya Kondo; Hiromitsu Takizawa; Koichiro Kenzaki; Haruhiko Fujino; Shoji Sakiyama; Akira Tangoku
Journal:  J Thorac Cardiovasc Surg       Date:  2006-03       Impact factor: 5.209

7.  Safety and Efficacy of Modified Preoperative Lung Nodule Microcoil Localization Without Pleural Marking: A Pilot Study.

Authors:  Lan-Chau T Kha; Kate Hanneman; Laura Donahoe; Taebong Chung; Andrew F Pierre; Kazuhiro Yasufuku; Shafique Keshavjee; John R Mayo; Narinder S Paul; Elsie T Nguyen
Journal:  J Thorac Imaging       Date:  2016-01       Impact factor: 3.000

8.  Near-infrared dye marking for thoracoscopic resection of small-sized pulmonary nodules: comparison of percutaneous and bronchoscopic injection techniques.

Authors:  Takashi Anayama; Kentaro Hirohashi; Ryohei Miyazaki; Hironobu Okada; Nobutaka Kawamoto; Marino Yamamoto; Takayuki Sato; Kazumasa Orihashi
Journal:  J Cardiothorac Surg       Date:  2018-01-12       Impact factor: 1.637

9.  Computed tomography guided percutaneous injection of a mixture of lipiodol and methylene blue in rabbit lungs: evaluation of localization ability for video-assisted thoracoscopic surgery.

Authors:  Kwang Nam Jin; Kyung Won Lee; Tae Jung Kim; Yong Sub Song; Dong Il Kim
Journal:  J Korean Med Sci       Date:  2013-12-26       Impact factor: 2.153

10.  Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients.

Authors:  Matthieu Hanauer; Jean Yannis Perentes; Thorsten Krueger; Hans-Beat Ris; Pierre Bize; Sabine Schmidt; Michel Gonzalez
Journal:  J Cardiothorac Surg       Date:  2016-01-16       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.