| Literature DB >> 33313170 |
Jung Seop Eom1, Hyo Yeong Ahn2, Yeong Dae Kim2, Insu Kim3, Hee Yun Seol4.
Abstract
BACKGROUND: Since peripheral lung lesions can be frequently visualized on computed tomography (CT), various methods of localization for thoracoscopic surgery have been developed. In the case of transbronchial dye injection (TDI), there can be difficulties with dye visualization through the thoracoscope depending on early disappearance of the dye due to diffusion before field exposure. Herein, we performed an animal experiment to determine the appropriate dye amount and the duration of visualization.Entities:
Keywords: Transbronchial injection; detection; lung nodule; marker; visualization
Year: 2020 PMID: 33313170 PMCID: PMC7723521 DOI: 10.21037/atm-20-1695
Source DB: PubMed Journal: Ann Transl Med ISSN: 2305-5839
Figure 1Thoracoscopic images showing changes in the dye extent over time depending on the amount of dye injected and the use of air injection.
Detection time, peak time, and wash-out time depending on the amount of dye injected
| Amount of dye injected (mL) | P value | |||
|---|---|---|---|---|
| 0.6 | 0.8 | 1 | ||
| Detection time (minutes) | 4.53±0.59 | 2.67±1.48 | 2.2±1.65 | 0.195 |
| Peak time (minutes) | 28.07±5.12 | 34.13±3.26 | 42.97±10.86 | 0.092 |
| Wash-out time (minutes) | 117.23±68.61 | 134.07±15.72 | 134.67±74.44 | 0.06 |
Detection time, peak time, and wash-out time depending on use of air injection
| Air injection | P value | ||
|---|---|---|---|
| No | Yes | ||
| Detection time (minutes) | 3.27±1.90 | 2.2±1.65 | 0.5 |
| Peak time (minutes) | 12.1±1.6 | 28.07±5.12 | 0.07 |
| Wash-out time (minutes) | 46.23±10.58 | 134.07±15.72 | 0.001 |
Measured sizes of the dye extent at the detection time, peak time, and wash-out time depending on the amount of dye injected
| Measured size of the | Amount of dye injected (mL) | P value | ||
|---|---|---|---|---|
| 0.6 | 0.8 | 1 | ||
| Detection time | 5.87±2.01 | 12.56±0.86 | 15.6±1.57 | 0.001 |
| Peak time | 7.3±2.11 | 13.37±0.96 | 16.7±1.37 | 0.001 |
| Wash-out time | 5.1±1.72 | 9.76±1.00 | 11.5±0.75 | 0.002 |
Figure 2Size of the dye extend depending on (A) the amount of dye and time, and (B) use of air injection. (A) The size of the dye extent is significantly different depending on the amount of dye injected; (B) the size of the dye extent is significantly smaller in group 4 (no air injection) (P<0.001), and the size of the dye extent is significantly different depending on air injection.*, Mean time was described under every graph.
Measured size of the dye extent at the detection time, peak time, and wash-out time depending on the use of air injection
| Measured size of the dye extent (mm) | Air injection | P value | |
|---|---|---|---|
| No | Yes | ||
| Detection time | 7.13±1.65 | 15.60±1.57 | 0.003 |
| Peak time | 9.17±1.47 | 16.70±1.37 | 0.003 |
| Wash-out time | 6.10±0.75 | 11.50±0.75 | 0.001 |