Literature DB >> 33312905

Transcatheter valve-in-valve implantation in degenerated aortic bioprostheses: are patients with small surgical bioprostheses at higher risk for unfavourable mid-term outcomes?

Clarence Pingpoh1,2, Holger Schroefel1,2, Tanja Franz1,2, Martin Czerny1,2, Maximilian Kreibich1,2, Martin Moser3, Christoph Bode3, Friedhelm Beyersdorf1,2, Franz-Josef Neumann4, Willibald Hochholzer4, Matthias Siepe1,2.   

Abstract

BACKGROUND: To examine outcomes of valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) according to the inner diameter (ID) of the degenerated aortic valve bioprosthesis.
METHODS: We analyzed survival, stroke, permanent pacemaker (PPM) implantation, paravalvular (PV) leakage, acute kidney injury and vascular complications in fifty-nine patients during a ten-year period. Patients were stratified according to the ID of the indwelling degenerated biological aortic valve (true ID ≤ and >20 mm). Differences in post-procedural transvalvular gradients and hospital re-admissions were analyzed.
RESULTS: The median age of the small diameter group and large diameter group was eighty-one and eighty years, respectively. Median logistic EuroSCORE I was 23.9% and 26.2% and median Society of Thoracic Surgeons (STS) score was 5.7% and 7.8% for the small and large groups, respectively. Survival, stroke, PPM implantation, PV leakage, acute kidney injury and vascular complications did not reach any statistically significant difference between both groups. Postprocedural transvalvular gradients differed significantly according to the true ID of the degenerated bioprosthetic valve and consequently of the respective TAVI valve. There was a significant difference with regard to hospital readmissions according to the true ID.
CONCLUSIONS: TAVI ViV implantation for aortic bioprostheses with small true IDs of ≤20 mm is associated with comparable mid-term mortality and periprocedural stroke rate compared to implantation into larger bioprostheses. However, the periprocedural and mid-term transvalvular gradients, as well as hospital re-admission rates are significantly higher in the small diameter group. 2020 Annals of Cardiothoracic Surgery. All rights reserved.

Entities:  

Keywords:  Transcatheter valve implantation; aortic valve prosthesis; mortality; transvalvular gradient; true inner diameter (true ID)

Year:  2020        PMID: 33312905      PMCID: PMC7724066          DOI: 10.21037/acs-2020-av-fs-0124

Source DB:  PubMed          Journal:  Ann Cardiothorac Surg        ISSN: 2225-319X


  22 in total

Review 1.  The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years.

Authors:  Stuart J Head; Mostafa M Mokhles; Ruben L J Osnabrugge; Philippe Pibarot; Michael J Mack; Johanna J M Takkenberg; Ad J J C Bogers; Arie Pieter Kappetein
Journal:  Eur Heart J       Date:  2012-03-08       Impact factor: 29.983

2.  Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium.

Authors:  Martin B Leon; Nicolo Piazza; Eugenia Nikolsky; Eugene H Blackstone; Donald E Cutlip; Arie Pieter Kappetein; Mitchell W Krucoff; Michael Mack; Roxana Mehran; Craig Miller; Marie-angéle Morel; John Petersen; Jeffrey J Popma; Johanna J M Takkenberg; Alec Vahanian; Gerrit-Anne van Es; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys
Journal:  J Am Coll Cardiol       Date:  2011-01-07       Impact factor: 24.094

3.  CT-Defined Prosthesis-Patient Mismatch Downgrades Frequency and Severity, and Demonstrates No Association With Adverse Outcomes After Transcatheter Aortic Valve Replacement.

Authors:  John Mooney; Stephanie L Sellers; Phillip Blanke; Philippe Pibarot; Rebecca T Hahn; Danny Dvir; Pamela S Douglas; Neil J Weissman; Susheel K Kodali; Vinod H Thourani; Hasan Jilaihawi; Omar Khalique; Craig R Smith; Shaw Hua Kueh; Mickael Ohana; Romi Grover; Christopher Naoum; Aaron Crowley; Wael A Jaber; Maria C Alu; Rupa Parvataneni; Michael Mack; John G Webb; Martin B Leon; Jonathon A Leipsic
Journal:  JACC Cardiovasc Interv       Date:  2017-07-19       Impact factor: 11.195

4.  Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

Authors:  Peter Johansen; Henrik Engholt; Mariann Tang; Rasmus F Nybo; Per D Rasmussen; Jens Erik Nielsen-Kudsk
Journal:  EuroIntervention       Date:  2017-10-13       Impact factor: 6.534

5.  Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.

Authors:  Matheus Simonato; John Webb; Ran Kornowski; Alec Vahanian; Christian Frerker; Henrik Nissen; Sabine Bleiziffer; Alison Duncan; Josep Rodés-Cabau; Guilherme F Attizzani; Eric Horlick; Azeem Latib; Raffi Bekeredjian; Marco Barbanti; Thierry Lefevre; Alfredo Cerillo; José María Hernández; Giuseppe Bruschi; Konstantinos Spargias; Alessandro Iadanza; Stephen Brecker; José Honório Palma; Ariel Finkelstein; Mohamed Abdel-Wahab; Pedro Lemos; Anna Sonia Petronio; Didier Champagnac; Jan-Malte Sinning; Stefano Salizzoni; Massimo Napodano; Claudia Fiorina; Antonio Marzocchi; Martin Leon; Danny Dvir
Journal:  Circ Cardiovasc Interv       Date:  2016-06       Impact factor: 6.546

6.  Incidence, predictors and clinical outcomes of residual stenosis after aortic valve-in-valve.

Authors:  Sabine Bleiziffer; Magdalena Erlebach; Matheus Simonato; Philippe Pibarot; John Webb; Lukas Capek; Stephan Windecker; Isaac George; Jan-Malte Sinning; Eric Horlick; Massimo Napodano; David M Holzhey; Petur Petursson; Alfredo Cerillo; Nikolaos Bonaros; Enrico Ferrari; Mauricio G Cohen; Giselle Baquero; Tara L Jones; Ankur Kalra; Michael J Reardon; Adnan Chhatriwalla; Vasco Gama Ribeiro; Sami Alnasser; Nicolas M Van Mieghem; Christian Jörg Rustenbach; Joachim Schofer; Santiago Garcia; Tobias Zeus; Didier Champagnac; Raffi Bekeredjian; Ran Kornowski; Rüdiger Lange; Danny Dvir
Journal:  Heart       Date:  2018-01-19       Impact factor: 5.994

7.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

Authors:  Danny Dvir; John G Webb; Sabine Bleiziffer; Miralem Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil E Moat; Massimo Napodano; Manuel Wilbring; Alfredo G Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre; Federico De Marco; Claudia Fiorina; Anna Sonia Petronio; Rui C Teles; Luca Testa; Jean-Claude Laborde; Martin B Leon; Ran Kornowski
Journal:  JAMA       Date:  2014-07       Impact factor: 56.272

8.  Redo aortic valve surgery versus transcatheter valve-in-valve implantation for failing surgical bioprosthetic valves: consecutive patients in a single-center setting.

Authors:  Magdalena Erlebach; Michael Wottke; Marcus-André Deutsch; Markus Krane; Nicolo Piazza; Ruediger Lange; Sabine Bleiziffer
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

9.  Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement.

Authors:  Frédéric Poulin; Teerapat Yingchoncharoen; William M Wilson; Eric M Horlick; Philippe Généreux; E Murat Tuzcu; William Stewart; Mark D Osten; Anna Woo; Paaladinesh Thavendiranathan
Journal:  J Am Heart Assoc       Date:  2016-02-08       Impact factor: 5.501

10.  Prosthesis-Patient Mismatch after Surgical Aortic Valve Replacement: Neither Uncommon nor Harmless.

Authors:  Sérgio da Costa Rayol; Michel Pompeu Barros Oliveira Sá; Luiz Rafael Pereira Cavalcanti; Felipe Augusto Santos Saragiotto; Roberto Gouvea Silva Diniz; Frederico Browne Correia de Araujo E Sá; Alexandre Motta Menezes; Frederico Pires Vasconcelos Silva; Ricardo Carvalho Lima
Journal:  Braz J Cardiovasc Surg       Date:  2019-06-01
View more
  1 in total

1.  Report on outcomes of valve-in-valve transcatheter aortic valve implantation and redo surgical aortic valve replacement in the Netherlands.

Authors:  G J van Steenbergen; B van Straten; K Y Lam; D van Veghel; L Dekker; P A Tonino
Journal:  Neth Heart J       Date:  2021-08-09       Impact factor: 2.380

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.