Literature DB >> 33301362

Remote Monitoring With Appropriate Reaction to Alerts Was Associated With Improved Outcomes in Chronic Heart Failure: Results From the OptiLink HF Study.

Jan Wintrich1, Valérie Pavlicek1, Johannes Brachmann2, Ralph Bosch3, Christian Butter4,5, Hanno Oswald6, Karin Rybak7, Felix Mahfoud1, Michael Böhm1, Christian Ukena1.   

Abstract

BACKGROUND: Impedance-based remote monitoring (RM) failed to reduce clinical events in the OptiLink heart failure (HF) trial. However, rates of alert-driven interventions triggered by intrathoracic fluid index threshold crossings (FTC) were low indicating physicians' inappropriate reactions to alerts.
METHODS: We separated appropriate from inappropriate contacts to FTC transmissions in the OptiLink HF trial (Optimization of Heart Failure Management Using OptiVol™ Fluid Status Monitoring and CareLink™). Appropriate contacts had to meet the following criteria: (1) initial telephone contact within 2 working days after FTC transmission, (2) follow-up contacts according to study protocol, and (3) medical intervention initiated after FTC due to cardiac decompensation. We compared time to cardiovascular death or HF hospitalization between RM patients contacted appropriately or inappropriately and patients with usual care.
RESULTS: In the RM group, at least one FTC alert was transmitted in 356 patients (70.5%; n=505). Of note, only 55.5% (n=758) of all transmitted FTCs (n=1365) were followed by an appropriate contact. While 113 patients (31.7%; n=356) have been contacted appropriately after every FTC, in 243 patients (68.3%; n=356) at least one FTC was not responded by an appropriate contact. Compared with usual care, RM with appropriate contacts to FTC alerts independently reduced the risk of the primary end point (hazard ratio, 0.61 [95% CI, 0.39-0.95]; P=0.027).
CONCLUSIONS: RM appropriate reactions to FTC alerts are associated with significantly improved clinical outcomes in patients with advanced HF and implantable cardioverter-defibrillators.

Entities:  

Keywords:  defibrillators; heart failure; remote monitoring; telemedicine

Year:  2020        PMID: 33301362     DOI: 10.1161/CIRCEP.120.008693

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  2 in total

1.  The first survey on patient needs for remote monitoring of cardiac implantable electronic device in South Korea.

Authors:  You Mi Hwang; Ji-Hoon Kim
Journal:  Medicine (Baltimore)       Date:  2022-06-10       Impact factor: 1.817

2.  Decongestive treatment adjustments in heart failure patients remotely monitored with a multiparametric implantable defibrillators algorithm.

Authors:  Federico Guerra; Antonio D'Onofrio; Ermenegildo De Ruvo; Michele Manzo; Luca Santini; Giovanna Giubilato; Carmelo La Greca; Barbara Petracci; Giulia Stronati; Valter Bianchi; Annamaria Martino; Fabio Franculli; Paolo Compagnucci; Monica Campari; Sergio Valsecchi; Antonio Dello Russo
Journal:  Clin Cardiol       Date:  2022-05-03       Impact factor: 3.287

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.