| Literature DB >> 33300105 |
Craig E Hofferber1,2, J Cameron Beck3,4, Peter C Liacouras5,6,7, Jeffrey R Wessel7,8,9, Thu P Getka7,8,10.
Abstract
BACKGROUND: The purpose of this study was to evaluate the volumetric changes in partially edentulous alveolar ridges augmented with customized titanium ridge augmentation matrices (CTRAM), freeze-dried bone allograft, and a resorbable collagen membrane.Entities:
Year: 2020 PMID: 33300105 PMCID: PMC7726098 DOI: 10.1186/s40729-020-00269-9
Source DB: PubMed Journal: Int J Implant Dent ISSN: 2198-4034
Fig. 1Baseline CBCT demonstrating horizontal ridge deficiency
Fig. 2“Ideal” osseous contour digitally added (blue) to the 3D reconstruction of the CBCT scan
Fig. 3CTRAM designed over the digitally augmented ridge. Notches were designed in bone loading ports at 90° angles were documented as H1–H8 (or H1–H4 if the design included only one loading port). Four cam-shaped nutrient ports were included and documented as V1–V4. These served as measurement locations for pre- and post-graft clinical probing measurements
Fig. 4Surgical fixation of CTRAM at site #19 with two screws
Fig. 5CBCT 7 months post-operatively, suggesting complete bone fill
Fig. 6View of ridge after removal of CTRAM. Dimensions of new bone are confirmed to be sufficient for implant placement
Fig. 7a 3D reconstruction of baseline CBCT. b Global registration of pre- and post-operative 3D reconstructions; new bone shown in green. c Percentage bone fill calculated by comparing planned augmentation volume (pink) with the volume of new bone (green)
Volumetric bone gain
| Subject ID | Baseline volume (mm | Virtual model increase (mm | Post-grafting volume (mm | Percentage bone fill |
|---|---|---|---|---|
| 0 | 311.29 | 292.06 | 93.82 | |
| 0 | 507.44 | 614.64 | 121.13 | |
| 0 | 259.70 | 283.34 | 109.10 | |
| 0 | 242.68 | 238.84 | 98.42 | |
| 0 | 804.80 | 553.93 | 68.83 | |
| 0 | 297.45 | 203.88 | 68.54 | |
| 0 | 341.20 | 47.74 | 13.99 | |
| 0 | 299.01 | 243.33 | 81.38 | |
| 0 | 157.23 | 179.60 | 114.23 |
aSubjects with premature CTRAM exposure during healing
Volumetric gain stratified by the occurrence of premature CTRAM exposure
| Case outcome | Mean planned augmentation volume (mm | Mean post-graft volume (mm | Mean percentage bone fill |
|---|---|---|---|
| Premature CTRAM exposure | 438.687 | 274.403 | 61.296 ± 33.69 |
| No premature CTRAM exposure | 293.211 | 311.948 | 104.851 ± 15.52 |
aWilcoxon rank-sum test
Fig. 8Planned vs. actual augmentation volume. Amount of volumetric bone gain (mm3) vs. the planned volume of augmentation (mm3). Red points represent subjects who experienced premature mesh exposure
CTRAM placement discrepancy
| Subject ID | Point 1 difference (mm) | Point 2 difference (mm) | Point 3 difference (mm) | Point 4 difference (mm) | Mean difference (mm) |
|---|---|---|---|---|---|
| 0.56 | 0.31 | 0.31 | 0.41 | 0.39 | |
| 0.26 | 0.09 | 0.35 | 0.54 | 0.31 | |
| 1.07 | 1.13 | 0.76 | 0.68 | 0.91 | |
| 0.65 | 0.98 | 0.83 | 0.92 | 0.85 | |
| N/A | N/A | N/A | N/A | N/A | |
| 0.89 | 1.61 | 1.97 | 0.85 | 1.33 | |
| N/A | N/A | N/A | N/A | N/A | |
| 2.47 | 2.20 | 3.64 | 3.37 | 2.92 | |
| 0.47 | 0.90 | 1.16 | 1.11 | 0.91 | |
Linear distance in millimeters from designated points on CTRAM: planned location (in CAD software) vs. location on post-treatment CBCT. Post-treatment CBCT on subjects 5 and 7 (early CTRAM removal) were obtained following removal of CTRAM, and positional comparison could not be made
Clinical bone augmentation measurements
| Subject ID | Mean baseline horizontal (mm) | Mean baseline vertical (mm) | Mean final horizontal (mm) | Mean final vertical (mm) | Mean horizontal gain (mm) | Mean vertical gain (mm) |
|---|---|---|---|---|---|---|
| 3.875 | 5.2 | 1.75 | 2.5 | 2.125 | 2.7 | |
| 4.125 | 5.6 | 0.5 | 1 | 3.625 | 4.6 | |
| 4.5 | 5 | 0.125 | 1.25 | 4.375 | 3.75 | |
| 4 | 3.8 | 0.25 | 0.625 | 3.75 | 3.175 | |
| 4 | 4.2 | – | – | – | – | |
| 4.5 | 5 | 1.25 | 2.5 | 3.25 | 2.5 | |
| 3.5 | 4.4 | – | – | – | – | |
| 4 | 3.8 | 1.75 | 3 | 2.25 | 0.8 | |
| 2.75 | 3.4 | 0.625 | 0.5 | 2.125 | 2.9 | |
Average of linear measurements through CTRAM at designated locations