Literature DB >> 33298388

Postoperative evaluation of Er:YAG laser, piezosurgery, and rotary systems used for osteotomy in mandibular third-molar extractions.

Tayfun Civak1, Tugba Ustun2, Hanife Nuray Yilmaz3, Bahar Gursoy4.   

Abstract

OBJECTIVE: This study compared patient postoperative pain, swelling, and trismus after usage of rotary instruments, piezosurgery, and Er:YAG lasers in mandibular third-molar extraction.
MATERIALS AND METHODS: This prospective study was executed with class II and position B vertically impacted mandibular third molars. Patients were divided into three groups according to the osteotomy system used to remove retentive bone: rotary instruments, piezosurgery, and Er:YAG laser. Postoperative pain was evaluated using VAS questionnaires at 12 h, 24 h, 48 h, and 7 days after procedures. Trismus was evaluated by measuring the distance between the maxillary and mandibular incisors at maximum mouth opening, and comparing preoperative measurements with those for postoperative days 2 and 7. Analyses of swelling were carried out via a stereophotogrammetry system. Operation times were measured using a digital stopwatch from the initial incision to the final suture.
RESULTS: There were no statistically significant differences between the groups in terms of pain, trismus, or swelling (p > 0.05). Pain persisted more in the rotary instrument group 24 h later (0 ± 1.3; p = 0.001). The pain scores obtained after 48 h for the piezosurgery (1.81 ± 2.29) and rotary (2.2 ± 2.12) groups were observed at 24 h in the laser group (2.19 ± 1.52). The mean operation time was highest using the laser (19.1 ± 3.85 min; p = 0.001) and lowest using rotary instruments (9.88 ± 2.97 min; p = 0.001).
CONCLUSION: Piezosurgery and Er:YAG laser are good alternatives to rotary instrument systems in third-molar extraction, but both systems are slower than traditional rotary instruments.
Copyright © 2020 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Er:YAG laser; Piezosurgery; Stereophotogrammetry

Year:  2020        PMID: 33298388     DOI: 10.1016/j.jcms.2020.11.010

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  1 in total

1.  A Pilot Randomized Controlled Clinical Trial Comparing Piezo Versus Conventional Rotary Surgery for Removal of Impacted Mandibular Third Molars.

Authors:  Joana Saraiva Amaral; Carlos Miguel Marto; João Farias; Daniela Alves Pereira; Jorge Ermida; Álvaro Banaco; António Campos Felino; Francisco Caramelo; Sérgio Matos
Journal:  Bioengineering (Basel)       Date:  2022-06-25
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.