Literature DB >> 33298292

A simultaneous exploratory and quantitative amino acid and biogenic amine metabolic profiling platform for rapid disease phenotyping via UPLC-QToF-MS.

Nicola Gray1, Nathan G Lawler1, Rongchang Yang2, Aude-Claire Morillon2, Melvin C L Gay3, Sze-How Bong2, Elaine Holmes4, Jeremy K Nicholson5, Luke Whiley6.   

Abstract

Metabolic phenotyping using mass spectrometry (MS) is being applied to ever increasing sample numbers in clinical and epidemiology studies. High-throughput and robust methods are being developed for the accurate measurement of metabolites associated with disease. Traditionally, quantitative assays have utilized triple quadrupole (QQQ) MS based methods; however, the use of such focused methods removes the ability to perform discovery-based metabolic phenotyping. An integrated workflow for the hybrid simultaneous quantification of 34 biogenic amines in combination with full scan high-resolution accurate mass (HRAM) exploratory metabolic phenotyping is presented. Primary and secondary amines are derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate prior to revered-phase liquid chromatographic separation and mass spectrometric detection. Using the HRAM-MS data, retrospective phenotypic data mining could be performed, demonstrating the versatility of HRAM-MS instrumentation in a clinical and molecular epidemiological environment. Quantitative performance was assessed using two MS detector platforms: Waters TQ-XS (QQQ; n = 3) and Bruker Impact II QToF (HRAMS-MS; n = 2) and three human biofluids (plasma, serum and urine). Finally, each platform was assessed using a certified external reference sample (NIST SRM 1950 plasma). Intra- and inter-day accuracy and precision were comparable between the QQQ and QToF instruments (<15%), with excellent linearity (R2 > 0.99) over the quantification range of 1-400 μmol L-1. Quantitative values were comparable across all instruments for human plasma, serum and urine samples, and calculated concentrations were verified against certified reference values for NIST SRM 1950 plasma as an external reference. As a real-life biological exemplar, the method was applied to plasma samples obtained from SARS-CoV-2 positive patients versus healthy controls. Both the QQQ and QToF approaches were equivalent in being able to correctly classify SARS-CoV-2 positivity. Critically, the use of HRAM full scan data was also assessed for retrospective exploratory mining of data to extract additional biogenic amines of biomarker interest beyond the 34 quantified targets.
Copyright © 2020 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amino acids; Biogenic amines; COVID-19; Cross validation; High-resolution accurate mass; Metabolic profiling; Quantitative mass spectrometry; SARS-CoV-2; Triple quadrupole; UHPLC

Mesh:

Substances:

Year:  2020        PMID: 33298292     DOI: 10.1016/j.talanta.2020.121872

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Report on the 3rd Board Meeting of the International Human Phenome Consortium.

Authors:  Mei Tian; Han Liu; Shunling Chen; Zhong Yang; Weishuo Tao; Shiwen Peng; Huiting Che; Li Jin
Journal:  Phenomics       Date:  2022-06-22

2.  Systemic long-term metabolic effects of acute non-severe paediatric burn injury.

Authors:  Sofina Begum; Blair Z Johnson; Aude-Claire Morillon; Rongchang Yang; Sze How Bong; Luke Whiley; Nicola Gray; Vanessa S Fear; Leila Cuttle; Andrew J A Holland; Jeremy K Nicholson; Fiona M Wood; Mark W Fear; Elaine Holmes
Journal:  Sci Rep       Date:  2022-07-29       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.