Air and Environmental Contamination With Severe Acute Respiratory Syndrome Coronavirus 2 in Healthcare Settings
| Author, Year, Country | Air Sampling Situation | Patient Status | AGP Type | Air Sampling Method | Detection Method | Air Contamination | Result for Air/Environmental Samples |
|---|---|---|---|---|---|---|---|
| Cheng et al, 2020, China[ | Airborne infection isolation rooms with 12 air changes/h; an air shelter (an umbrella fitted with a transparent plastic curtain) used to cover patients | Symptomatic and asymptomatic cases | No AGP | Air samples collected 10 cm from a patient’s chin with or without a surgical mask inside the air shelter using the Sartorius MD8 airscan sampler at a rate of 50 L/min for 20 min (1,000 L of air) | RT-PCR | All of the air samples negative (0/6); air outlet fan contamination 2/3 | Negative/Positive |
| Chia et al, 2020, Singapore[ | Airborne isolation rooms with 12 air changes/h and exhaust flow of 579.6 m3/h throughout the 4-h sampling period | Symptomatic and asymptomatic cases | No AGP | 3 size fractions collected with NIOSH BC 251 bioaerosol samplers connected to SKC AirChek TOUCH Pumps or SKC universal air sampling pumps with 5,040 L of air from each patient’s room | RT-PCR | Air positive rate 66.7% (2/3); positive for particle sizes > 4 μm and 1–4 μm in diameter; negative for particle sizes < 1 μm; air exhaust vent positive rate 60% (3/5) | Positive/Positive |
| Guo et al, 2020, China[ | Isolation ward of the ICU (12 air supplies and 16 air discharges/h) and general ward (8 air supplies/h, 12 air discharges/h); indoor air and air outlets sampled to detect aerosol exposure | Severe cases in ICU and mild cases in general ward | NA | SASS 2300 Wetted Wall Cyclone Sampler at 300 L/min for 30 min | RT-PCR | Air positive rate 35% (14/40) in ICU and 12.5% (2/16) in general ward; air outlet positive rate 66.7% (8/12) in ICU and 8.3% (1/12) in general ward | Positive/Positive |
| Jerry et al, 2020, Ireland[ | Rooms of COVID-19 patients (intubated or receiving noninvasive ventilation) | Symptomatic cases | AGP | Air sampler SAS Super ISO 100 | RT-PCR | All air samples negative (0/16: 8 from patient rooms and 8 from corridors of COVID-19 wards) | Negative/Positive |
| Lei et al, 2020, China[ | ICU and isolation ward. The airflow in ICU rooms was a class-100 000 clean room with laminar flow. Average air change was 240/h to 360/h between 8 | Severe and critical cases | AGP; mechanical ventilation, bronchoscopy, intubation | NIOSH cyclonic bioaerosol sampler (for 4 hours at a flow rate of 3.5 L/min into 3 size fractions) and DingBlue sampler (at a flow rate of 14 L/min for 30 min); samplers placed on opposite sides at head of bed within 1 m of patient’s head at a height of 1.3 m | RT-PCR | 2 air samples in bathroom on 2 different days positive | Positive/Positive |
| Li et al, 2020, China[ | After 4 daily air disinfection by a plasma air sterilizer, aerosol samples were collected from various areas of a designated hospital for severe COVID-19 patients, including ICU ward with 12 air supplies/h and 16 discharges/h and isolation room with 8 air supplies/h and 12 discharges/h | Severe and critical cases | NA | Impingement air sampler BIO-Capturer-6 placed 1–1.5 m above floor in wards and 1–5 m from patients’ beds collected a total of 2,400 L air at a rate of 80 L/min for 30 min | RT-PCR | All aerosol samples negative (0/135) | Negative/Negative |
| Ong et al, 2020, Singapore[ | Airborne infection isolation rooms (12 air exchanges/h) | Mid symptomatic cases | No AGP | SKC universal pumps for 4 h at 5 L/min in patient room and anteroom; collected on 2 days | RT-PCR | All air samples negative; air outlet fan contamination 2/3 | Negative/Positive |
| Razzini et al, 2020, Italy[ | COVID-19 ward with negative airflow system; air samples collected from 3 zones (contaminated, semicontaminated, and clean areas) | Patients intubated and supported by a respirator, and a patient not intubated and without CPAP nasal mask support | AGP; intubated, supported by a respirator, or not intubated and without CPAP nasal mask support | MD8 air sampler | RT-PCR | All air samples from contaminated area of ICU and corridor positive; samples from semicontaminated or clean areas negative | Positive/Positive |
| Santarpia et al, 2020 USA[ | Negative pressure patient rooms with 12–15 air exchanges/h and hallways in the National Quarantine Unit on days 5–9 of occupancy and in the Nebraska Biocontainment Unit on day 10. Not all patients removed masks during air sampling; 58% of patients were symptomatic (eg, cough). | Mild symptomatic cases | No AGP | Sartorius Airport MD8 air sampler placed on bedside tables and nightstands at least 1 m away from patient; collected high-volume (50 L/min) stationary air samples. Personal Button Samplers (SKC) and AirChek pumps (SKC) used by study personnel to collect low-volume (4 L/min) personal air samples on 2 d during sampling activities | RT-PCR, viral culture | In-room air positive rate 63.2%; no virus cultured but viral proteins observed by immunofluorescence in hallway sample after 3 d cell culture | Positive/Positive |
| Wei et al, 2020, China[ | Negative-pressure, non-ICU in a designated isolation ward between 10:30 | Asymptomatic and mild symptomatic cases | No AGP | Air sampler FSC-1V placed ∼0.6 m away from each patient and 1 m above floor in each room for 15 minutes at 100 L/min. | RT-PCR | All air samples negative; air exhaust outlets 50% positive (3/6) | Negative/Positive |
| Zhou et al, 2020, UK[ | For the first procedure, before and during the procedure; for the other procedures, during the procedure only | Severe cases | AGP; tracheostomy | Coriolis μ air sampler to collect 1-m3 air samples | RT-PCR, viral culture | Air positive rate 6.4% (2/31) but no virus cultured; in operating theatres, 1/3 air samples collected during 3 tracheostomy procedures positive | Positive/Positive |
Note. AGP, aerosol-generating procedure; COVID-19, coronavirus disease 2019; CPAP, continuous positive airway pressure; ICU, intensive care unit; NA, not applicable; National Institute of Occupational Safety and Health, NIOSH; PPE, personal protective equipment; RT-PCR, reverse transcription polymerase chain reaction; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2.