Comparison between modified wet suction and dry suction technique for endoscopic ultrasound-guided fine-needle biopsy in pancreatic solid lesions.

Ting Tong1, Li Tian1, Minzi Deng1, Yang Liu2, Yening Yang2, Hua Yin3, Xiuyan Long1, Shiyu Pan1, Zhenyu Yang1, Weiwei Luo1, Kai Nie1, Xiangrui Meng1, Mengwei Xiao1, Xing Wu1, Chao Zhang1, Xiaoyan Wang1.   

Abstract

BACKGROUND AND AIM: Although endoscopic ultrasound-guided fine-needle biopsy is widely applied, there is no clear consensus on the optimal biopsy technique. We described a modified wet suction technique (MWEST) with the aim to compare the efficacy and safety between MWEST and the dry suction technique (DST).
METHODS: In this prospective, randomized, crossover, single-blinded study, patients with suspected pancreatic malignancy were randomized to the DST (group A) or MWEST (group B) for the first pass, and the two techniques were performed alternately. The primary outcome was the comparison of specimen adequacy and diagnostic yield between the techniques. Secondary outcomes included the macroscopic visible core length, blood contamination of specimens, and adverse events of both techniques.
RESULTS: From January 2019 to September 2019, 216 passes were performed in 50 patients. The specimen adequacy was significantly higher in "per-lesion" (P = 0.026), "per-pass" (cytology: P = 0.034; histology: P = 0.042), and first-pass analysis (P = 0.034) for MWEST than for DST. In diagnostic yield, MWEST showed significantly superior histological yield (P = 0.014) and first-pass analysis (κ: MWEST: 0.743 and DST: 0.519) compared with DST. The median macroscopic visible core lengths were 8 mm (interquartile range: 3.25-15 mm) and 10 mm (interquartile range: 5.25-15 mm) for DST and MWEST, respectively (P = 0.036). Blood contamination was significantly more serious in DST than in MWEST (cytology: P = 0.021; histology: P = 0.042).
CONCLUSIONS: Endoscopic ultrasound-guided fine-needle biopsy with MWEST resulted in significantly better quality of specimen, histological, and first-pass diagnostic yields and comparable safety compared with the DST. MWEST is preferred for endoscopic ultrasound-guided fine-needle biopsy in pancreatic solid lesions.
© 2020 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  Dry suction technique; Endoscopic ultrasound-guided fine-needle biopsy; Modified wet suction technique; Pancreatic solid lesions

Year:  2020        PMID: 33295070     DOI: 10.1111/jgh.15371

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  1 in total

1.  EUS-guided liver biopsy using a modified wet heparin suction technique.

Authors:  Ali Zakaria; Abdulrahman Diab; Michael Dowd; Pushpak Taunk; Ali Abbas
Journal:  VideoGIE       Date:  2022-08-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.