Literature DB >> 33290320

Thickness and Curvature Changes of Human Corneal Grafts in Dextran-Containing Organ Culture Medium Before Keratoplasty.

Loïc Hamon1, Loay Daas1, Stephanie Mäurer2, Isabel Weinstein1, Adrien Quintin1, Katja Schulz3, Achim Langenbucher2, Berthold Seitz1.   

Abstract

PURPOSE: To determine the changes of corneal thickness and curvature of human corneal grafts in organ culture medium II, containing dextran T500 6%, before keratoplasty.
METHODS: We examined the tomography of 24 corneas from our eye bank transferred from medium I into medium II. Images were repeated hourly during 24 hours using an anterior segment optical coherence tomography. The central corneal thickness (CCT) was measured with the manual measurement tool of the anterior segment optical coherence tomography. The radii of curvature (anterior flat and steep and posterior flat and steep) were measured with a MATLAB self-programmed software for "sterile donor tomography."
RESULTS: The mean CCT (±SD) at baseline (T0) was 727 ± 156 μm. It reached 581 ± 103, 506 ± 84, 472 ± 79, and 456±7 μm after 6, 12, 18, and 24 hours, respectively. After 12 hours, 83% of the final deswelling was achieved. The radii of curvature (±SD) at baseline (T0) were (posterior flat, posterior steep, anterior flat, and anterior steep) 6.6 ± 0.5, 6.2 ± 0.5, 7.7 ± 0.4, and 7.4 ± 0.4 mm, respectively. After 24 hours, the radii of curvature reached 6.8 ± 0.1, 6.6 ± 0.3, 7.6 ± 0.1, and 7.4 ± 0.2 mm, respectively.
CONCLUSIONS: The kinetics of the deswelling process in medium II follow a hyperbolic curve. Considering a CCT of 506 μm at T12, we assume that a time interval of 12 hours in medium II might be enough for clinical purposes. This result might help to keep storage in medium II as short as possible to escape potential toxic effects of dextran in medium II. The radius of curvature does not seem to change within 24 hours for all measured surfaces.
Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.

Entities:  

Year:  2021        PMID: 33290320     DOI: 10.1097/ICO.0000000000002543

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  1 in total

1.  [Comparison of sterile donor tomography in the eye bank and graft tomography after penetrating keratoplasty].

Authors:  A Quintin; L Hamon; S Mäurer; A Langenbucher; B Seitz
Journal:  Ophthalmologe       Date:  2020-11-30       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.