Literature DB >> 33284406

Transfemoral transcatheter aortic valve implantation for bicuspid aortic stenosis with tortuous aorta after total arch replacement.

Daisuke Hachinohe1, Hidemasa Shitan2, Umihiko Kaneko2, Ken Kobayashi2, Keijiro Mitsube3, Ryuji Koushima3.   

Abstract

Entities:  

Keywords:  Bicuspid aortic stenosis; Tortuous aorta; Total arch replacement; Transcatheter aortic valve implantation

Mesh:

Year:  2020        PMID: 33284406      PMCID: PMC8789732          DOI: 10.1007/s12928-020-00738-3

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


× No keyword cloud information.
A 72-year-old woman with a history of hypertension, diabetes mellitus, dyslipidemia, atrial fibrillation, and cardiogenic cerebral embolism had undergone total arch replacement 9 years ago. Recently, she has experienced exertional dyspnea. Transthoracic echocardiography revealed very severe aortic stenosis (AS) with an aortic valve (AV) area of 0.74 cm2, mean transaortic pressure gradient of 70 mmHg, and preserved left ventricular (LV) ejection fraction of 61%. Transesophageal echocardiography (TEE) and multidetector computed tomography imaging revealed type 0 calcified bicuspid AV based on the Sievers classification (annulus area: 478mm2 and inter-commissural length: 38.5 × 29.3 mm) (Fig. 1, panel A). The thoracoabdominal aorta showed tortuosity (Fig. 1, panel B), and her sinus of Valsalva of 35.0 × 41.0 mm in diameter was large compared with an artificial aortic graft of 20.6 × 24.7 mm, and the aortic angle was 55° (Fig. 1, panel C). Because of high frailty (clinical frailty scale score: 6 and short physical performance battery score: 5 points), the patient was referred for transfemoral transcatheter aortic valve implantation (TAVI).
Fig. 1

Transfemoral transcatheter aortic valve implantation (TAVI) for bicuspid aortic stenosis with a tortuous aorta after total arch replacement. a 3D computer tomography (CT) reconstruction shows type 0 calcified bicuspid aortic valve. b The tortuous thoracoabdominal aorta. c The synthetic prosthesis of the total arch replacement and the large ascending aorta. d Catheter prolapses (double-headed allows) at the ascending part to the arch graft and the tortuous thoracoabdominal aorta (Online video 1). e Straighten the catheter using double stiff guidewires (allows). f Balloon aortic valvuloplasty with 23-mm balloon. g Easy crossing of SAPIEN 3 through the aorta and aortic valve [Online video 2]. h Good result after TAVI without any complications

Transfemoral transcatheter aortic valve implantation (TAVI) for bicuspid aortic stenosis with a tortuous aorta after total arch replacement. a 3D computer tomography (CT) reconstruction shows type 0 calcified bicuspid aortic valve. b The tortuous thoracoabdominal aorta. c The synthetic prosthesis of the total arch replacement and the large ascending aorta. d Catheter prolapses (double-headed allows) at the ascending part to the arch graft and the tortuous thoracoabdominal aorta (Online video 1). e Straighten the catheter using double stiff guidewires (allows). f Balloon aortic valvuloplasty with 23-mm balloon. g Easy crossing of SAPIEN 3 through the aorta and aortic valve [Online video 2]. h Good result after TAVI without any complications The TAVI was performed under general anesthesia. After placing a Safari2 (Boston Scientific, USA) small curve wire in the mid LV, balloon aortic valvuloplasty (BAV) was tried using Z-MEDII 23 × 40 mm (B BRAUN, USA) to make it easier to cross the device due to very severe AS and to confirm the valve size in type 0 bicuspid AV. However, the balloon could not cross to AV because of strong resistance at the ascending part to the arch graft and the tortuous thoracoabdominal aorta (Fig. 1, panel D, online video 1). Consequently, we changed the Safari2 wire to a Lunderquist Extra Stiff (Cook Medical, USA) and advanced another stiff guidewire through a 5 French pigtail catheter (Fig. 1, panel E). Then, the 23-mm balloon was crossed without resistance and BAV was performed (Fig. 1, panel F). A 26-mm SAPIEN 3 (Edwards Lifesciences, USA) was easily crossed through the aorta and AV (Fig. 1, panel G, online video 2), and implanted during rapid ventricular pacing with underfilling volume of a delivery balloon. TEE and aortography revealed neither significant aortic regurgitation nor other potential complications (Fig. 1, panel H). This is the first case report showing the feasibility of transfemoral TAVI in patients with bicuspid AS after total arch replacement with a tortuous aorta. Generally, in patients with extremely tortuous access root, the buddy wire technique is useful [1]. In this case, the patient had a bicuspid AS, which is usually associated with aortopathy and leads to an ascending aortic aneurysm. The diameter difference between the enlarged aortic root and narrow artificial aortic graft, and the extremely tortuous aorta could have represented a resistance point that led to difficulty in manipulation of the catheter. The buddy stiff guidewire could straighten the access root and reduce resistance points, leading to a greater pushing force against the resistance force. Transfemoral TAVI with buddy wire technique could be feasible for treating bicuspid AS after total arch replacement with a tortuous aorta. Below is the link to the electronic supplementary material. Online video 1: Catheter prolapses (double-headed allows) at the ascending part to the arch graft and the tortuous thoracoabdominal aorta.1 (MP4 7148 KB) Online video 2: Easy crossing of SAPIEN 3 through the aorta and aortic valve.2 (MP4 9670 KB)
  1 in total

1.  Use of double stiff wire allows successful transfemoral transcatheter aortic valve implantation through extreme thoracic aorta tortuosity.

Authors:  Nicola Buzzatti; Antonio Mangieri; Linda Cota; Neil Ruparelia; Vittorio Romano; Ottavio Alfieri; Antonio Colombo; Matteo Montorfano
Journal:  Circ Cardiovasc Interv       Date:  2015-04       Impact factor: 6.546

  1 in total
  1 in total

1.  Management of Transcatheter Aortic Valve Implantation and Complex Aorta Anatomy: The Importance of Pre-Procedural Planning.

Authors:  Alfredo Intorcia; Vittorio Ambrosini; Michele Capasso; Riccardo Granata; Fabio Magliulo; Giannignazio Luigi Carbone; Stefano Capobianco; Francesco Rotondi; Francesca Lanni; Fiore Manganelli; Emilio Di Lorenzo
Journal:  Int J Environ Res Public Health       Date:  2022-04-14       Impact factor: 3.390

  1 in total