Application of TG-218 action limits to SRS and SBRT pre-treatment patient specific QA.

Yuqing Xia1, Justus Adamson2, Yana Zlateva2, Will Giles2.   

Abstract

AAPM TG-218 provides recommendations for standard IMRT pre-treatment QA without giving specifics for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). In light of this, our purpose is to report our experience with applying TG-218 recommendations to a large multicenter clinical SRS and SBRT program for a range of diverse clinical pre-treatment QA systems. Pre-treatment QA systems included Delta4 (Scandidos), Portal Dosimetry (Varian Medical Systems), ArcCHECK (SunNuclear), and SRS MapCHECK (SunNuclear). Plans were stratified by technique for each QA system, and included intracranial and extracranial IMRT and VMAT (total QA cases n=275). Gamma analysis was re-analyzed with spatial/dose criteria combinations ranging from 1 to 3 mm and 1% to 4%, and action and tolerance limits were calculated per plan type and compared to the "universal" TG-218 action limit of 90%. The analysis indicated that spatial tolerance criteria could be tightened to 1 mm while still maintaining an in-control QA process for all QA systems evaluated.
© 2020 Old City Publishing, Inc.

Entities:  

Keywords:  Gamma analyses; IMRT&VMAT QA; SBRT; SRS

Year:  2020        PMID: 33282467      PMCID: PMC7717087     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  21 in total

1.  Stereotactic body radiation therapy: the report of AAPM Task Group 101.

Authors:  Stanley H Benedict; Kamil M Yenice; David Followill; James M Galvin; William Hinson; Brian Kavanagh; Paul Keall; Michael Lovelock; Sanford Meeks; Lech Papiez; Thomas Purdie; Ramaswamy Sadagopan; Michael C Schell; Bill Salter; David J Schlesinger; Almon S Shiu; Timothy Solberg; Danny Y Song; Volker Stieber; Robert Timmerman; Wolfgang A Tomé; Dirk Verellen; Lu Wang; Fang-Fang Yin
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  A new metric for assessing IMRT modulation complexity and plan deliverability.

Authors:  Andrea L McNiven; Michael B Sharpe; Thomas G Purdie
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

3.  A technique for the quantitative evaluation of dose distributions.

Authors:  D A Low; W B Harms; S Mutic; J A Purdy
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

4.  National survey of patient specific IMRT quality assurance in China.

Authors:  Yuxi Pan; Ruijie Yang; Shuming Zhang; Jiaqi Li; Jianrong Dai; Junjie Wang; Jing Cai
Journal:  Radiat Oncol       Date:  2019-04-25       Impact factor: 3.481

5.  Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA.

Authors:  Yair Hillman; Josh Kim; Indrin Chetty; Ning Wen
Journal:  Med Phys       Date:  2018-03-01       Impact factor: 4.071

Review 6.  Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

Authors:  Moyed Miften; Arthur Olch; Dimitris Mihailidis; Jean Moran; Todd Pawlicki; Andrea Molineu; Harold Li; Krishni Wijesooriya; Jie Shi; Ping Xia; Nikos Papanikolaou; Daniel A Low
Journal:  Med Phys       Date:  2018-03-23       Impact factor: 4.071

7.  Quality and safety considerations in stereotactic radiosurgery and stereotactic body radiation therapy: Executive summary.

Authors:  Timothy D Solberg; James M Balter; Stanley H Benedict; Benedick A Fraass; Brian Kavanagh; Curtis Miyamoto; Todd Pawlicki; Louis Potters; Yoshiya Yamada
Journal:  Pract Radiat Oncol       Date:  2011-09-15

8.  Breaking bad IMRT QA practice.

Authors:  Strahinja Stojadinovic; Luo Ouyang; Xuejun Gu; Arnold Pompoš; Qinan Bao; Timothy D Solberg
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

9.  Characterization and clinical evaluation of a novel IMRT quality assurance system.

Authors:  Ramaswamy Sadagopan; Jose A Bencomo; Rafael L Martin; Gorgen Nilsson; Thomas Matzen; Peter A Balter
Journal:  J Appl Clin Med Phys       Date:  2009-05-07       Impact factor: 2.102

10.  Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT.

Authors:  Vladimir Feygelman; Kenneth Forster; Daniel Opp; Görgen Nilsson
Journal:  J Appl Clin Med Phys       Date:  2009-09-30       Impact factor: 2.102

View more
  6 in total

1.  The current status and shortcomings of stereotactic radiosurgery.

Authors:  Hunter Mehrens; Trang Nguyen; Sharbacha Edward; Shannon Hartzell; Mallory Glenn; Daniela Branco; Nadia Hernandez; Paola Alvarez; Andrea Molineu; Paige Taylor; Stephen Kry
Journal:  Neurooncol Adv       Date:  2022-04-20

2.  Verification of an optimizer algorithm by the beam delivery evaluation of intensity-modulated arc therapy plans.

Authors:  Tamas Pocza; Domonkos Szegedi; Tibor Major; Csilla Pesznyak
Journal:  Radiol Oncol       Date:  2021-11-19       Impact factor: 2.991

3.  Determination of commissioning criteria for multileaf-collimator, stereotactic radiosurgery treatments on Varian TrueBeam and Edge machines using a novel anthropomorphic phantom.

Authors:  Thomas A D Brown; Jessica M Fagerstrom; Caleb Beck; Connor Holloway; Krista Burton; Darryl G L Kaurin; Saikanth Mahendra; Marcus Luckstead; Kayla Kielar; James Kerns
Journal:  J Appl Clin Med Phys       Date:  2022-03-15       Impact factor: 2.243

4.  An introduction to key performance indicators for medical physicists.

Authors:  Dominic J DiCostanzo; Lalith K Kumaraswamy; Jillian Shuman; Daniel C Pavord; Yanle Hu; David W Jordan; Christopher Waite-Jones; Annie Hsu
Journal:  J Appl Clin Med Phys       Date:  2022-07-13       Impact factor: 2.243

5.  Evaluation of a two-dimensional diode array for patient-specific quality assurance of HyperArc.

Authors:  Richard A Popple; Rodney J Sullivan; Yuan Yuan; Xingen Wu; Elizabeth L Covington
Journal:  J Appl Clin Med Phys       Date:  2021-11-01       Impact factor: 2.102

6.  Implementing and evaluating a high-resolution diode array for patient-specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy.

Authors:  Qianyi Xu; Kiet Huynh; Wei Nie; Mark S Rose; Ashish K Chawla; Kevin S Choe; Samir Kanani; Gregory J Kubicek; Jiajin Fan
Journal:  J Appl Clin Med Phys       Date:  2022-03-12       Impact factor: 2.243

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.