Fractured Needle Removal With a 3-Dimensionally Printed Surgical Guide: A Case Report and Literature Review.

Driesen Lukas1, Meeus Jan2, Politis Constantinus3, Legrand Paul4.   

Abstract

Needle breakage is a rare complication of inferior alveolar nerve block anesthesia. This study proposes a new localization technique. We used a three-dimensionally printed surgical guide, supported by the lower dental arch to minimize the required surgical access. With this approach, the procedure could be performed with procedural sedation anesthesia.
Copyright © 2020 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 33271183     DOI: 10.1016/j.joms.2020.11.002

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  2 in total

1.  Fractured needle as an unusual complication of the lingual nerve block: a case report.

Authors:  Aras Erdil; Mustafa Sami Demirsoy; Sefa Çolak
Journal:  J Dent Anesth Pain Med       Date:  2022-07-26

2.  Accidental Insertion of a Broken Needle into the Pterygoid Mandibular Space during Inferior Alveolar Nerve Block: A Case Report.

Authors:  Kazuhiro Terada; Kenji Yamagata; Fumihiko Uchida; Satoshi Fukuzawa; Naomi Ishibashi-Kanno; Hiroki Bukawa
Journal:  Case Rep Dent       Date:  2022-08-17