| Literature DB >> 33270899 |
Andreas Christ1, Theodoros Samaras2, Esra Neufeld1, Niels Kuster1,3.
Abstract
The latest electromagnetic safety guidelines define transmitted or epithelial power density as the basic restriction above 6 GHz. In this note, we derive an approximation for a conservative transmission coefficient for quasi plane wave incidence as a function of the frequency for the normal component of the Poynting vector with respect to the evaluation plane or tissue surface |Sz inc| and for its modulus ||Sinc||. The maximum transmission coefficient for the normal component of the Poynting vector ${\boldsymbol{T}}_{\mathbf{z}}^{\mathbf{max}}$ is 1 independent of tissue composition and frequency. Approximations of ${\boldsymbol{T}}_{\mathbf{total}}^{\mathbf{max}}$ normalized to ||Sinc|| for thin and thick stratum corneum are provided allowing higher exposures. These approximations allow to conservatively demonstrate compliance with basic restrictions when quasi plane-wave conditions are locally satisfied and enhancement effects of standing waves between source and body can be neglected. The reported results are important to regulators and standardization bodies regarding revisions of compliance requirements and safety guidelines.Mesh:
Year: 2020 PMID: 33270899 DOI: 10.1093/rpd/ncaa179
Source DB: PubMed Journal: Radiat Prot Dosimetry ISSN: 0144-8420 Impact factor: 0.972