Literature DB >> 33270835

Internal Hexagon vs Conical Implant-Abutment Connections: Evaluation of 3-Year Postloading Outcomes.

Sorin Gheorghe Mihali1, Hom-Lay Wang2, Olimpiu Karancsi3, Emanuel Adrian Bratu3.   

Abstract

Different types of internal implant-abutment connections, namely hexagon and conical, have been used for implant restoration. However, data regarding the benefits of these internal connections in terms of clinical outcomes are scarce. Accordingly, the aim of this study was to compare radiographic marginal bone loss (RMBL) and associated implant complications between implants with internal hexagon (IH) connections and those with internal conical (IC) connections. Forty-nine patients with 98 implants (2 per patient) placed in the posterior mandible were recruited. All implants were inserted in pairs into solid D2 bone according to a randomized sequence; the first patient received an IH connection implant on the mesial side, while the second patient received an IC connection implant on the mesial side. Each patient received 1 implant with an IH connection and 1 with an IC connection, placed side by side. Four months after placement, all implants were loaded with single screw-retained ceramic restorations with IH or IC connections. RMBL and complications, including implant/prosthesis failure, were recorded at the time of implant loading (baseline) and at 6, 12, and 36 months after loading. The results revealed no significant between-group differences in RMBL (P = .74), gingival bleeding on probing (P = .29), and complications (P = .32). Thus, the type of internal implant-abutment connection did not affect clinical outcomes, including RMBL and implant/prosthesis failure. Future studies should additionally evaluate long-term prosthesis-related complications, such as screw loosening and fracture, between the 2 types of internal connections.

Entities:  

Keywords:  bone remodeling; conical connection; dental implant–abutment connection; hexagon connection; screw-retained restorations

Mesh:

Substances:

Year:  2021        PMID: 33270835     DOI: 10.1563/aaid-joi-D-19-00160

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  1 in total

1.  Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series.

Authors:  James Rudolph Collins; Brendha P Ogando; Houlin Hong; Wei Hou; Georgios E Romanos
Journal:  Dent J (Basel)       Date:  2022-06-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.