| Literature DB >> 33268967 |
Liu-Jia-Zi Shao1, Yi Zou1, Fu-Kun Liu1, Lei Wan1, Shao-Hua Liu1, Fang-Xiao Hong1, Fu-Shan Xue2.
Abstract
BACKGROUND: Hypoxemia due to respiratory depression and airway obstruction during upper gastrointestinal endoscopy with sedation is a common concern. The Wei nasal jet tube (WNJT) is a new nasopharyngeal airway with the ability to provide supraglottic jet ventilation and oxygen insufflation via its built-in wall channel. The available evidence indicates that with a low oxygen flow, compared with nasal cannula, the WNJT does not decrease the occurrence of hypoxemia during upper gastrointestinal endoscopy with propofol sedation. To date, there has been no study assessing the performance of WNJT for supplemental oxygen during upper gastrointestinal endoscopy with sedation when a moderate oxygen flow is used. AIM: To determine whether the WNJT performs better than the nasal prongs for the prevention of hypoxemia during gastroscopy with propofol mono-sedation when a moderate oxygen flow is provided in patients with a normal body mass index.Entities:
Keywords: Adverse outcomes; Gastroscopy; Hypoxemia; Nasal cannula; Supplemental oxygen; Wei nasal jet tube
Mesh:
Substances:
Year: 2020 PMID: 33268967 PMCID: PMC7684457 DOI: 10.3748/wjg.v26.i43.6867
Source DB: PubMed Journal: World J Gastroenterol ISSN: 1007-9327 Impact factor: 5.742
Figure 1Wei nasal jet tube.
Figure 2Flow chart of included and excluded patients in this study. ASA: American Society of Anesthesiologists; BMI: Body mass index; WNJT: Wei nasal jet tube.
Baseline characteristics of patients, procedure time and total propofol dosage
|
|
|
|
|
| Age (yr) | 53 (40, 60) | 55 (41, 60) | 0.537 |
| Gender (M/F) | 43/101 | 46/98 | 0.702 |
| Body mass index (kg/m2) | 23 (21,24) | 22 (21,24) | 0.086 |
| ASA physical classification (1/2) | (32/112) | (41/103) | 0.223 |
| Baseline SpO2 (%) | 98 (97, 99) | 98 (97, 98) | 0.061 |
| Procedure times (min) | 5.0 (4.4, 5.2) | 4.8 (4.5, 5.0) | 0.002 |
| Total propofol dosages (mg) | 160 (140, 188) | 140 (120, 160) | 0.000 |
Data are presented as median (interquartile range) or number of patients. SpO2: Pulse oxygen saturation; ASA: American Society of Anesthesiologists; WNJT: Wei nasal jet tube.
Hypoxemia and lowest pulse oxygen saturation during the gastroscopy, and interventions related to hypoxemia and adverse events
|
|
|
|
|
| Total occurrence of hypoxemia | 3 (2.1) | 21 (14.6) | 0.000 |
| Hypoxemia | 2 (1.4) | 19 (13.2) | 0.000 |
| Severe hypoxemia | 1 (0.7) | 2 (1.4) | 1.000 |
| Lowest SpO2 | 98 (97, 99) | 96 (93, 98) | 0.000 |
| Airway opening maneuvers | 4 (2.8) | 36 (25) | 0.000 |
| Facemask ventilation | 0 (0) | 4 (2.8) | 0.131 |
| Body movement | 8 (5.6) | 9 (6.3) | 0.803 |
| Cough | 10 (6.9) | 11 (7.6) | 0.821 |
| Epistaxis (0/1/2/3) | 0/7/0/0 (4.9) | 0 (0) | 0.022 |
| Sore throat | 2 (1.4) | 3 (2.1) | 1.000 |
Data are presented as median (interquartile range) or number of patients (percent). SpO2: Pulse oxygen saturation; WNJT: Wei nasal jet tube.
Satisfactions of physicians, anesthetists and patients
|
|
|
|
| ||||
|
|
|
|
|
|
| ||
| Physicians | 143 (99.3) | 1 (0.7) | 0 | 139 (96.5) | 4 (2.8) | 1 (0.7) | 0.214 |
| Anesthetists | 140 (97.2) | 4 (2.8) | 0 | 134 (93.1) | 8 (5.6) | 2 (1.4) | 0.196 |
| Patients | 142 (98.6) | 2 (1.4) | 0 | 144 (100) | 0 | 0 | 0.498 |
Data are presented as number of patients (percent). WNJT: Wei nasal jet tube.
Figure 3Epistaxis observed by gastroscopy in patients with Wei nasal jet tube placement.