Literature DB >> 33263447

Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial.

Goulven Rochcongar1, Matthieu Remazeilles1, Emeline Bourroux1, Julien Dunet1, Valentin Chapus1, Matthieu Feron1, César Praz1, Geoffrey Buia1, Christophe Hulet1.   

Abstract

Background and purpose - Vitamin E-infused polyethylene is a relatively new material in joint arthroplasty; there are no long-term reports, and only few mid-term results. Using radiostereometric analysis (RSA), we primarily determined whether vitamin E-infused highly cross-linked polyethylene (HXLPE/VitE) acetabular cups show less wear than ultra-high molecular weight polyethylene (UHMWPE) acetabular cups at 5 years after total hip arthroplasty (THA). We also assessed whether wear rates correlate with increasing cup inclination angles or cup sizes.Patients and methods - This is a 5-year follow-up of our previously reported randomized controlled trial of 62 patients with 3 years' follow-up, who received THA with either an HXLPE/VitE or a UHMWPE acetabular cup. At 5 years, 40 patients were analyzed (22 in the HXLPE/VitE and 18 in the UHMWPE group).Results - HXLPE/VitE cups continued to show less cumulative femoral head penetration than UHMWPE cups (HXLPE/VitE: 0.24 mm, UHMWPE: 0.45 mm; p < 0.001). Distribution of wear was also more even with HXLPE/VitE cups than with UHMWPE cups (p = 0.002). Moreover, the difference in PE wear between 1 and 5 years in both groups showed no statistically significant correlation with increasing cup inclination angles or cup sizes. Finally, no osteolysis and implant loosening occurred, and no revision surgeries were required.Interpretation - Wear rates continue to be lower in HXLPE/VitE cups than in UHMWPE cups at 5 years of follow-up without correlation with increasing cup inclination angles or cup sizes. Finally, HXLPE/VitE cups may have the potential to prevent osteolysis and implant loosening.

Entities:  

Year:  2020        PMID: 33263447     DOI: 10.1080/17453674.2020.1852785

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  3 in total

Review 1.  Characterisation of Selected Materials in Medical Applications.

Authors:  Kacper Kroczek; Paweł Turek; Damian Mazur; Jacek Szczygielski; Damian Filip; Robert Brodowski; Krzysztof Balawender; Łukasz Przeszłowski; Bogumił Lewandowski; Stanisław Orkisz; Artur Mazur; Grzegorz Budzik; Józef Cebulski; Mariusz Oleksy
Journal:  Polymers (Basel)       Date:  2022-04-09       Impact factor: 4.967

2.  Vitamin E-Enhanced Liners in Primary Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Qian-Yue Cheng; Bin-Fei Zhang; Peng-Fei Wen; Jun Wang; Lin-Jie Hao; Tao Wang; Hui-Guang Cheng; Ya-Kang Wang; Jian-Bin Guo; Yu-Min Zhang
Journal:  Biomed Res Int       Date:  2021-12-06       Impact factor: 3.411

3.  Identification of Key Candidate Genes Related to Inflammatory Osteolysis Associated with Vitamin E-Blended UHMWPE Debris of Orthopedic Implants by Integrated Bioinformatics Analysis and Experimental Confirmation.

Authors:  Fanxiao Liu; Jun Dong; Dongsheng Zhou; Qingyu Zhang
Journal:  J Inflamm Res       Date:  2021-07-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.