Literature DB >> 33263313

Attenuation correction for human PET/MRI studies.

Ciprian Catana1.   

Abstract

Attenuation correction has been one of the main methodological challenges in the integrated positron emission tomography and magnetic resonance imaging (PET/MRI) field. As standard transmission or computed tomography approaches are not available in integrated PET/MRI scanners, MR-based attenuation correction approaches had to be developed. Aspects that have to be considered for implementing accurate methods include the need to account for attenuation in bone tissue, normal and pathological lung and the MR hardware present in the PET field-of-view, to reduce the impact of subject motion, to minimize truncation and susceptibility artifacts, and to address issues related to the data acquisition and processing both on the PET and MRI sides. The standard MR-based attenuation correction techniques implemented by the PET/MRI equipment manufacturers and their impact on clinical and research PET data interpretation and quantification are first discussed. Next, the more advanced methods, including the latest generation deep learning-based approaches that have been proposed for further minimizing the attenuation correction related bias are described. Finally, a future perspective focused on the needed developments in the field is given.

Entities:  

Year:  2020        PMID: 33263313     DOI: 10.1088/1361-6560/abb0f8

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Evaluation of Deep Learning-Based Approaches to Segment Bowel Air Pockets and Generate Pelvic Attenuation Maps from CAIPIRINHA-Accelerated Dixon MR Images.

Authors:  Hasan Sari; Ja Reaungamornrat; Onofrio A Catalano; Javier Vera-Olmos; David Izquierdo-Garcia; Manuel A Morales; Angel Torrado-Carvajal; Thomas S C Ng; Norberto Malpica; Ali Kamen; Ciprian Catana
Journal:  J Nucl Med       Date:  2021-07-22       Impact factor: 11.082

2.  Monte Carlo Characterization of the Trimage Brain PET System.

Authors:  Luigi Masturzo; Pietro Carra; Paola Anna Erba; Matteo Morrocchi; Alessandro Pilleri; Giancarlo Sportelli; Nicola Belcari
Journal:  J Imaging       Date:  2022-01-23

3.  A Path to Qualification of PET/MRI Scanners for Multicenter Brain Imaging Studies: Evaluation of MRI-Based Attenuation Correction Methods Using a Patient Phantom.

Authors:  Ciprian Catana; Richard Laforest; Hongyu An; Fernando Boada; Tuoyu Cao; David Faul; Bjoern Jakoby; Floris P Jansen; Bradley J Kemp; Paul E Kinahan; Peder Larson; Michael A Levine; Piotr Maniawski; Osama Mawlawi; Jonathan E McConathy; Alan B McMillan; Julie C Price; Abhejit Rajagopal; John Sunderland; Patrick Veit-Haibach; Kristen A Wangerin; Chunwei Ying; Thomas A Hope
Journal:  J Nucl Med       Date:  2021-07-22       Impact factor: 11.082

  3 in total