Literature DB >> 332577

Study of gastric emptying using a ferromagnetic tracer.

Y Benmair, F Dreyfuss, B Fischel, E H Frei, T Gilat.   

Abstract

A new ferromagnetic method for the measurement of gastric emptying is described. An inert tracer, magnesium ferrite, is added to a test meal. Its amount in the stomach is then measured at regular intervals by an external transducer using its ferromagnetic properties. The method is noninvasive and devoid of radiation exposure. The magnetic fields used are harmless. The feasibility, reliability, and reproducibility of the method are described. Gastric emptying was studied in 61 subjects. The shape of the gastric emptying curve conformed best to an exponential function. The mean half-time of gastric emptying was 49 +/- 17.4 min. In this limited series age and sex did not affect gastric emptying.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 332577

Source DB:  PubMed          Journal:  Gastroenterology        ISSN: 0016-5085            Impact factor:   22.682


  6 in total

1.  Measurement of segmental transit through the gut in man. A novel approach by the biomagnetic method.

Authors:  M Basile; M Neri; A Carriero; S Casciardi; S Comani; C Del Gratta; L Di Donato; S Di Luzio; M A Macri; A Pasquarelli
Journal:  Dig Dis Sci       Date:  1992-10       Impact factor: 3.199

2.  Biomagnetic techniques for evaluating gastric emptying, peristaltic contraction and transit time.

Authors:  Jose María De la Roca-Chiapas; Teodoro Cordova-Fraga
Journal:  World J Gastrointest Pathophysiol       Date:  2011-10-15

3.  Biomagnetic 3-dimensional spatial and temporal characterization of electrical activity of human stomach.

Authors:  H D Allescher; K Abraham-Fuchs; R E Dunkel; M Classen
Journal:  Dig Dis Sci       Date:  1998-04       Impact factor: 3.199

4.  Electrical bioimpedance and other techniques for gastric emptying and motility evaluation.

Authors:  María Raquel Huerta-Franco; Miguel Vargas-Luna; Juana Berenice Montes-Frausto; Corina Flores-Hernández; Ismael Morales-Mata
Journal:  World J Gastrointest Pathophysiol       Date:  2012-02-15

5.  Dosimetry of swallowed non absorbed 99mTc radiopharmaceuticals in pediatric patients.

Authors:  S Wynchank; M D Mann; R Gonin
Journal:  Eur J Nucl Med       Date:  1990

6.  Gastric emptying of solids measured by means of magnetised iron oxide powder.

Authors:  M Forsman
Journal:  Med Biol Eng Comput       Date:  1998-01       Impact factor: 2.602

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.