Mandy Wootton1, Leanne Davies2, Katherine Pitman2, Robin A Howe2. 1. Specialist Antimicrobial Chemotherapy Unit (SACU), Public Health Wales, University Hospital of Wales, Cardiff, United Kingdom. Electronic address: Mandy.wootton@wales.nhs.uk. 2. Specialist Antimicrobial Chemotherapy Unit (SACU), Public Health Wales, University Hospital of Wales, Cardiff, United Kingdom.
Abstract
OBJECTIVES: To evaluate the accuracy and reproducibility of antimicrobial susceptibility testing methods in Burkholderia cepacia complex (BCC). METHODS: Minocycline, ciprofloxacin, trimethoprim/sulphamethoxazole, meropenem, ceftazidime and chloramphenicol were tested against 155 BCC strains using broth microdilution at 35 ± 1°C (BMD35) in triplicate, then BMD at 30 ± 1°C (BMD30), agar dilution at 30°C and 35°C (AD30 and AD35), gradient strip (GS) and EUCAST standardized disc diffusion (DD) testing methods once. RESULTS: BMD35 reproducibility ranged from 70% to 84.5% for all agents. Correlations of MICs from BMD35 with BMD30 ranged from 63% to 85%, with AD35 from 32.9% to 87% and with GS methods from 36% to 83.9%. Essential agreement (EA) of MICs by GS with BMD35 ranged from 62.6% (trimethoprim-sulphamethoxazole) to 83.9% (minocycline). EA of EUCAST DD zone diameters using CLSI breakpoint criteria was between 85.8% and 97.4%, however Very Major Errors (VME) for trimethoprim/sulphamethoxazole were 31%. CONCLUSIONS: BMD at 35 ± 1°C was poorly reproducible for most agents and no method showed acceptable performance. Of particular concern were the GS results. Although this is the most commonly used method for determining MICs in laboratories, there was poor correlation with BMD35 for meropenem and trimethoprim/sulphamethoxazole. EUCAST DD correlated poorly with BMD35 MICs. This study confirms that no susceptibility method is capable of providing reproducible and accurate MICs when testing BCC.
OBJECTIVES: To evaluate the accuracy and reproducibility of antimicrobial susceptibility testing methods in Burkholderia cepacia complex (BCC). METHODS:Minocycline, ciprofloxacin, trimethoprim/sulphamethoxazole, meropenem, ceftazidime and chloramphenicol were tested against 155 BCC strains using broth microdilution at 35 ± 1°C (BMD35) in triplicate, then BMD at 30 ± 1°C (BMD30), agar dilution at 30°C and 35°C (AD30 and AD35), gradient strip (GS) and EUCAST standardized disc diffusion (DD) testing methods once. RESULTS: BMD35 reproducibility ranged from 70% to 84.5% for all agents. Correlations of MICs from BMD35 with BMD30 ranged from 63% to 85%, with AD35 from 32.9% to 87% and with GS methods from 36% to 83.9%. Essential agreement (EA) of MICs by GS with BMD35 ranged from 62.6% (trimethoprim-sulphamethoxazole) to 83.9% (minocycline). EA of EUCAST DD zone diameters using CLSI breakpoint criteria was between 85.8% and 97.4%, however Very Major Errors (VME) for trimethoprim/sulphamethoxazole were 31%. CONCLUSIONS:BMD at 35 ± 1°C was poorly reproducible for most agents and no method showed acceptable performance. Of particular concern were the GS results. Although this is the most commonly used method for determining MICs in laboratories, there was poor correlation with BMD35 for meropenem and trimethoprim/sulphamethoxazole. EUCAST DD correlated poorly with BMD35 MICs. This study confirms that no susceptibility method is capable of providing reproducible and accurate MICs when testing BCC.
Authors: Holly K Huse; Mark J Lee; Mandy Wootton; Susan E Sharp; Maria Traczewski; John J LiPuma; Peter Jorth Journal: J Clin Microbiol Date: 2021-09-15 Impact factor: 5.948
Authors: Rola Kwayess; Housam Eddine Al Hariri; Joya-Rita Hindy; Nada Youssef; Sara F Haddad; Souha S Kanj Journal: J Epidemiol Glob Health Date: 2022-06-30