First experiences with the balloon-expandable Myval® transcatheter aortic valve from Turkey.

Uğur Arslan1, Güney Erdoğan1, Melisa Uçar1, Mustafa Yenerçağ1.   

Abstract

Entities:  

Year:  2020        PMID: 33253135      PMCID: PMC7791291          DOI: 10.14744/AnatolJCardiol.2020.93584

Source DB:  PubMed          Journal:  Anatol J Cardiol        ISSN: 2149-2263            Impact factor:   1.596


× No keyword cloud information.

Introduction

Transcatheter aortic valve implantation (TAVI), first performed in inoperable patients with severe valvular aortic stenosis (AS), has become a surgical alternative even in low surgical risk patients based on the PARTNER-3 trial (1). TAVI valves can be classified into two categories: self-expandable and balloon-expandable. The experience of the operator and patients’ clinical characteristics, such as aortoiliac-femoral access and distribution of calcium extending to left ventricular outflow tract (LVOT), are important for the choice of the valve. However, post-procedural aortic regurgitation and need for a permanent pacemaker are more commonly observed with self-expandable valves. Recent trials with the balloon-expandable SAPIEN 3 (Edwards Lifesciences, USA) valve have shown superior clinical results to the surgical aortic replacement and self-expandable valves (2). In our clinics, we prefer balloon-expandable valves because of its superiority, but in select cases which have extensive LVOT calcification and unsuitable peripheral access, the self-expandable Evolut-R (Medtronic, USA) valve is preferred. The balloon-expandable Myval prosthetic valve (Meril Life Sciences, India), has been evaluated in the Myval-1 study (3) and has shown clinical efficacy and safety. In this study with 30 intermediate-to-high risk AS patients, all the procedures were successful with no paravalvular leaks or post-procedural permanent pacemaker implantations. A European Community mark has been given to this valve and Myval entered the market in Turkey earlier this year. The structure of the Myval valve is like the SAPIEN-3 valve (Fig. 1a), but there are several differences which favor Myval. A 14-Fr expandable sheath is used during the insertion of the valve, which is smaller than the SAPIEN-XT or SAPIEN-3 entry system. Another difference is that it is crimped on the balloon catheter system, which may be an advantage because the SAPIEN valves are mounted on the balloon in the descending aorta. Sizes for larger aortic annuli (30.5 mm and 32 mm) are available for the Myval valve. Intermediate sizes (21.5 mm, 24.5 mm, and 27.5 mm) are available which decrease the risk of annular rupture, a serious complication of balloon-expandable valves. These sizes are expected be available in Turkey soon.
Figure 1

The Myval valve and its implantation procedure. (a) Structural appearance of the valve. (b) After positioning the aortic cusps in a straight line, valve is placed to the optimal position, then under rapid ventricular pacing, the balloon of the valve is inflated a bit and the dog-bone appearance occurs. Just at this time aortography is performed to prove the correct position of the valve. (c) The balloon is fully inflated still under rapid pacing. (d) After deflating the balloon, the valve is implanted to the correct position. In aortography, no aortic regurgitation is observed

The Myval valve and its implantation procedure. (a) Structural appearance of the valve. (b) After positioning the aortic cusps in a straight line, valve is placed to the optimal position, then under rapid ventricular pacing, the balloon of the valve is inflated a bit and the dog-bone appearance occurs. Just at this time aortography is performed to prove the correct position of the valve. (c) The balloon is fully inflated still under rapid pacing. (d) After deflating the balloon, the valve is implanted to the correct position. In aortography, no aortic regurgitation is observed Balloon pre-dilatation is recommended before the Myval valve implantation. Because of our experience in SAPIEN XT and SAPIEN 3 valves, we do not routinely perform pre-dilatation when inserting the balloon-expandable valves. Direct TAVI has also been shown as effective and safe as TAVI procedures with pre-dilatation (4). Pre-dilatation is performed when the operator feels that the passage of the AL-1 or AL-2 diagnostic catheter through the aortic valve is difficult with the straight 0.035” wire. In this article, we present our experiences with the first 9 TAVI procedures using the Myval valve in June and July 2020. The clinical, electrocardiographic, and procedural characteristics of the patients are summarized in Table 1. In all the patients, the TAVI procedure succeeded. The procedural technique is like the SAPIEN XT and 3 valve implantation (Fig. 1a-1d). Video 1 shows one TAVI procedure with the Myval valve. As we have mentioned, the differences were the lower profile sheath used for the entry and the valve itself, which is mounted on the balloon outside the body, not in the descending aorta. A marker can be placed in the middle of the valve between other two markers showing the proximal and distal edges of the valve. This marker helps align the valve to the aortic annulus, which should be at the level of the lower border of the non-coronary cusp).
Table 1

The clinical characteristics of 9 patients undergoing TAVI with Myval valve

PatientsAgeSexSTS scoreAortic gradients (max-mean) (mm Hg)AVA (cm2)Aortic annular area (mm2)Size of Myval Valve (mm)Pre-dilatationPost-dilatationPost-imp.mean gradients (mm Hg)Post-imp. ARBaseline ECGPost-procedural immediate ECGPre-discharge ECGComplication
Patient 173M10.887/560.746026NoNo10NoSR (QRS: 90 msec)SR, incomplete LBBB (QRS:110 msec)SR (QRS: 90 msec)No
Patient 271M10.274/460.873029NoNo10NoSR, LVH voltage criteriaSR, LVH voltage criteriaSR, LVH voltage criteriaNo
Patient 385M11.171/410.747526NoNo9NoAF (QRS: 80 msec)Complete AV blockPace rhythmAV block
Patient 481M10.399/550.766029NoNo8NoSR, LBBB (QRS: 150 msec)SR, LBBB (QRS: 160 msec)SR, LBBB (QRS: 150 msec)No
Patient 576F5.175/480.851026NoNo7NoNSRNSRNSRNo
Patient 691M10.980/510.767029NoNo10MildSR, LVH voltage criteria (QRS: 120 msec)SR, LBBB (QRS: 160 msec)SR, LVH voltage crieria (QRS :120 msec)No
Patient 772M10.770/450.946526NoNo9NoSR, LVH voltage crieria (QRS: 110 msec)SR, LVH voltage crieria (QRS: 110 msec)SR, LVH voltage crieria (QRS: 110 msec)No
Patient 878F11.772/450.837023NoNo8NoPace rhythmPace rhythmPace rhythmNo
Patient 978M8.1100/600.656529NoNo10NoSR, LVH voltage crieria (QRS: 110 msec)SR, nonspecific IVCD (QRS: 130 msec)SR, LVH voltage crieria (QRS: 110 msec)No

STS - Society of Thoracic Surgeons, ECG - electrocardiogram, AVA - aortic valve area, AR - aortic regurgitation, SR - sinus rhythm, LBBB - left bundle branch block, LVH - left ventricular hypertrophy, AF - atrial fibrillation, AV - atrioventricular, IVCD - intraventricular conduction defect

The clinical characteristics of 9 patients undergoing TAVI with Myval valve STS - Society of Thoracic Surgeons, ECG - electrocardiogram, AVA - aortic valve area, AR - aortic regurgitation, SR - sinus rhythm, LBBB - left bundle branch block, LVH - left ventricular hypertrophy, AF - atrial fibrillation, AV - atrioventricular, IVCD - intraventricular conduction defect Under mild or no sedation, our TAVI procedures were performed via 14Fr sheath using 2 ProGlide pre-closure systems (Abbott Vascular, USA). We performed these cases without pre-dilatation, and no difficulty was observed during the valvular passage and implantation. No death or cerebrovascular event was recorded during hospitalization. Post-procedural mean transvalvular gradient was 9±2 mm Hg. Mild paravalvular regurgitation was observed only in one patient. A permanent pacemaker was also implanted in one patient after the procedure. In this patient, when the straight 0.035” wire passed into the left ventricle, a complete atrioventricular block developed which had not resolved 48 hours after the procedure. In eight patients, the procedural time was less than one hour and in one patient, because of severe peripheral tortuosity, it was 110 minutes. Two patients were discharged on the second day, 6 patients on the third day, and only one patient on the fourth day after valvular implantation. The development of this transcatheter Myval system is important because of the relatively lower cost when compared to the other balloon-expandable TAVI systems and its efficacy, which is comparable to the SAPIEN-3 valve (3). Longer term follow-up studies are needed to see the durability of the valve. However, Myval TAVI system is operator friendly because of the lower entry profile, which allows its use in patients with poor vascular access. The intermediate sizes are expected to decrease the risk of annular rupture.

Conclusion

In this article, we have presented our positive experience with the Myval valve. Long-term studies of this new valve are in progress. We believe that use of this valve will increase worldwide after these trials because of its ease of implantation and favorable hemodynamic profile.

Video 1

Implantation of the Myval valve to the aortic position
  4 in total

1.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

2.  Prior Balloon Valvuloplasty Versus Direct Transcatheter Aortic Valve Replacement: Results From the DIRECTAVI Trial.

Authors:  Florence Leclercq; Pierre Robert; Mariama Akodad; Jean-Christophe Macia; Thomas Gandet; Delphine Delseny; Marine Chettouh; Laurent Schmutz; Gabriel Robert; Gilles Levy; Frederic Targosz; Eric Maupas; Francois Roubille; Gregory Marin; Nicolas Nagot; Bernard Albat; Benoit Lattuca; Guillaume Cayla
Journal:  JACC Cardiovasc Interv       Date:  2020-03-09       Impact factor: 11.195

Review 3.  Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures.

Authors:  Chekrallah Chamandi; Rishi Puri; Tania Rodriguez-Gabella; Josep Rodés-Cabau
Journal:  Can J Cardiol       Date:  2017-03-25       Impact factor: 5.223

4.  First-in-Human Evaluation of Balloon Expandable Transcatheter Heart Valve in the Treatment of Severe Symptomatic Native Aortic Stenosis: The MyVal-1 Study.

Authors:  Samin K Sharma; Ravinder Singh Rao; Praveen Chandra; Pravin Kumar Goel; Prashant Bharadwaj; George Joseph; Ajaykumar U Mahajan; Sanjay Mehrotra; Gunasekaran Sengottovelu; V K Ajit Kumar; Cholenahally N Manjunath; Rajpal K Abhaichand; Ashok Seth
Journal:  EuroIntervention       Date:  2019-10-01       Impact factor: 6.534

  4 in total
  2 in total

1.  Transcatheter aortic valve implantation via the left axillary artery route in a patient with a permanent pacemaker: The first transaxillary artery route experience with a Meril's MyvalTM transaortic valve in Turkey.

Authors:  Telat Keleş; Özlem Özcan Çelebi; Emrah Uğuz; Kevser Balcı; Engin Bozkurt
Journal:  Anatol J Cardiol       Date:  2021-07       Impact factor: 1.596

2.  First experience in Turkey with Meril's MyValTM transcatheter aortic valve-in valve replacement for degenerated PERCEVALTM bioprothesis valve.

Authors:  Mehmet Erdoğan; Ahmet Kasapkara; Selçuk Öztürk; Cem Çöteli; Serdal Baştuğ; Nihal Akar Bayram; Murat Akçay; Tahir Durmaz
Journal:  Anatol J Cardiol       Date:  2022-02       Impact factor: 1.596

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.