Literature DB >> 33249803

Prospective evaluation of fiducial marker placement quality and toxicity in liver CyberKnife stereotactic body radiotherapy.

Debnarayan Dutta1, Kaushik Jagannath Kataki1, Shibu George2, Sruthi K Reddy1, Ajay Sashidharan1, Rajesh Kannan2, Ram Madhavan1, Haridas Nair1, Tushar Tatineni1, Raghavendra Holla3.   

Abstract

BACKGROUND: Evaluate morbidities and "quality" of fiducial marker placement in primary liver tumours (hepatocellular carcinoma [HCC]) for CyberKnife.
MATERIALS AND METHODS: Thirty-six HCC with portal vein thrombosis(PVT) were evaluated for "quality" of fiducial placement, placement time, pain score, complications, recovery time and factors influencing placement.
RESULTS: One hundred eight fiducials were placed in 36 patients. Fiducial placement radiation oncologist score was "good" in 24(67%), "fair" in 4(11%), and "poor" in 3(8%) patients. Concordance with radiologist score in "poor", "fair", and "good" score was 2/2(100%), 4/5(80%), and 24/27(89%), respectively(p=0.001). Child-Pugh score(p=0.080), performance status(PS) (p=0.014) and accrued during "learning curve"(p=0.013) affected placement score. Mean placement time(p=0.055), recovery time(p=0.025) was longer and higher major complications(p=0.009) with poor PS. Liver segment involved(p=0.484) and the Barcelona Clinic Liver Cancer(BCLC) stage did not influence placement score. "Good" placement score was 30% in first cohort whereas 93% in last cohort(p=0.023). Time for placement was 42.2 and 14.3 minutes, respectively(p=0.069). Post-fiducial pain score 0-1 in 26 patients(72%) and pain score 3-4 was in 2(6%). Five patients (14%) admitted in "day-care"(2 mild pneumothorax, 3 pain). Mortality in 1 patient(3%) admitted for hemothorax.
CONCLUSION: Fiducial placement is safe and in experienced hands, "quality" of placement is "good" in majority. Major complications and admission after fiducial placement are rare. Complications, fiducial placement time, recovery time is more during the "learning curve". Poor Child-Pugh score, extensive liver involvement, poor PS have higher probability of complications.

Entities:  

Keywords:  Fiducial marker; Hepatocellular carcinoma; Stereotactic body radiotherapy

Year:  2020        PMID: 33249803     DOI: 10.3857/roj.2020.00472

Source DB:  PubMed          Journal:  Radiat Oncol J        ISSN: 2234-1900


  1 in total

1.  Hepatocellular carcinoma effective stereotactic body radiotherapy using Gold Anchor and the Synchrony system: Two case reports and review of literature.

Authors:  Sakue Masuda; Toshitaka Tsukiyama; Yumiko Minagawa; Kazuya Koizumi; Makoto Kako; Takeshi Kinbara; Uojima Haruki
Journal:  World J Clin Cases       Date:  2022-03-16       Impact factor: 1.337

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.