Progressive QRS Duration and Ventricular Dysfunction in Pediatric Patients with Chronic Ventricular Pacing.

Richard J Czosek1,2, Zhiqian Gao3, Jeffrey B Anderson3,4, Timothy K Knilans3,4, Nicholas J Ollberding4,5, David S Spar3,4.   

Abstract

Pacemakers are a mainstay of therapy for patients with congenital and acquired heart block, but ventricular pacing is related to ventricular dysfunction. We sought to evaluate patient and device characteristics associated with ventricular dysfunction in pediatric patients with chronic ventricular pacing. This was a retrospective cohort of pediatric patients with heart block and chronic ventricular pacing. Patient, ECG, and device characteristics were analyzed to determine factors associated with ventricular dysfunction. Longitudinal ECG and echocardiogram parameters were obtained to track changes in QRS and systemic ventricular systolic function over time. In total, 82 patients were included (median age at implant 0.81 years). Over a follow-up time of 6.1 years, 18% developed ventricular dysfunction. Patients with dysfunction had greater current QRS duration (p = 0.002) compared to those with preserved function with a similar time from device implantation. There was no difference between lead location or age at device implantation. QRS duration increased with time from implant and the resultant ΔQRS was associated with ventricular dysfunction (p = 0.01). QRS duration >162 ms was associated with a 5.8 (2-9)-fold increased risk for dysfunction. Transvenous leads were associated with longer QRS duration with no difference compared to epicardial leads in development of ventricular dysfunction. This study demonstrated that the absolute paced QRS duration and Δpaced QRS were association with long-term ventricular dysfunction independent of how long a given patient was paced. Patients in high-risk categories may benefit from close echocardiographic monitoring. Whether permissive junctional rhythm or His bundle/biventricular pacing decreases the rate of dysfunction needs further study.

Entities:  

Keywords:  Dyssynchrony; Heart block; Heart failure; Pacemaker; Pediatrics; Ventricular dysfunction

Mesh:

Year:  2020        PMID: 33247765     DOI: 10.1007/s00246-020-02504-x

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  1 in total

1.  Conduction System Pacing in Pediatrics and Congenital Heart Disease, a Single Center Series of 24 Patients.

Authors:  Amanda Gordon; Erick Jimenez; Daniel Cortez
Journal:  Pediatr Cardiol       Date:  2022-06-09       Impact factor: 1.655

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.