Literature DB >> 33241579

Application of transesophageal echocardiography for localization in totally implantable venous access port implantation through subclavian approach in children.

Shujun Yang1,2,3,4,5,6, Xiangru Kong7,2,3,4,5,6, Lifei Liu1,2,3,4,5,6, Ying Xu1,2,3,4,5,6, Jun Zhang7,2,3,4,5,6.   

Abstract

A totally implantable venous access port (TIVAP) is important in children who need intravenous infusion for a long time. A number of studies have shown methods for locating the tip of the TIVAP catheter. To explore whether transesophageal echocardiography (TEE) can be used to accurately locate the TIVAP catheter tip through a subclavian approach and to improve the rate of correct TIVAP catheter placement and reduce complications of TIVAP placement. In 36 children who needed TIVAP implantation surgery, we used real-time TEE guidance to place the catheter tip around the crista terminalis. In all children, chest X-rays were used to figure out whether the catheter tip as localized by TEE was within the T5-T7 segment. Then, we compared the length of the catheter calculated by the height formula and the actual catheter length applied under TEE guidance. The medical records, surgical details, nursing records, and recorded complications were collected during the follow-up. The success rate of TIVAP implantation was 100% in all enrolled patients and no hemopneumothorax or pinch-off syndrome occurred. Compared with TEE, chest X-ray showed a coincidence rate of 80.56% in correctly detecting the TIVAP catheter tip locate. The height-derived catheter length (11.0 [9.6, 11.8]) cm and the TEE-derived catheter length (10.0 [9.3, 10.8]) cm were significantly different (p < .001). TEE can be used to guide TIVAP catheter positioning through a left subclavian approach in children accurately and successfully and more accurate than chest X-ray and height calculation formula.
© 2020 The Authors. Clinical Cardiology published by Wiley Periodicals LLC.

Entities:  

Keywords:  chest X-ray; subclavian vein; superior vena cava; totally implantable venous access port; transesophageal echocardiography

Year:  2020        PMID: 33241579     DOI: 10.1002/clc.23518

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  2 in total

1.  Transesophageal echocardiography-guided implantation of totally implantable venous access devices via the internal jugular vein: retrospective analysis of 297 cases in pediatric patients.

Authors:  Yuanzhen Chen; Dajun Xing; Lixin Wu; Huatian Lin; Ting Lin; Fang Ding; Liang Xu
Journal:  World J Surg Oncol       Date:  2022-08-30       Impact factor: 3.253

2.  Intelligent Internet of Things Medical Technology in Implantable Intravenous Infusion Port in Children with Malignant Tumors.

Authors:  Shaohong Liu; Luxing Jiang; Xin Wang
Journal:  J Healthc Eng       Date:  2021-11-28       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.