Literature DB >> 33233891

Rapid Identification and Quantification of Microplastics in the Environment by Quantum Cascade Laser-Based Hyperspectral Infrared Chemical Imaging.

Sebastian Primpke1, Matthias Godejohann2, Gunnar Gerdts1.   

Abstract

The monitoring of the emerging contaminant, microplastics, in the environment, in water supply, and for food safety is of major interest to science, consumers, and governments. While the chemical analysis of these particles is considered mandatory, a rapid and reliable method for the determination of particle sizes, shapes, and numbers is missing, as existing methods are not fitting into current laboratory measurement routines. In this study, we present an approach for circumventing these issues through the application of quantum cascade laser-based microscopy combined with an automated data analysis. This method allows the measurement of an area of 144 mm2 in 36 min, with a pixel resolution of 4.2 μm, which is an appropriate timeframe and spatial resolution for routine measurements. The performance was compared to the existing state-of-the-art Fourier transform infrared microscopy analyses. Further, the application of the method on various environmental samples was investigated to examine its capacity to provide number and variety of present particles. The described analytical procedure overcomes the last restrictions for schedulable and rapid microplastic monitoring, resulting in a highly detailed data set for particle numbers, particle shapes, and polymer types.

Entities:  

Year:  2020        PMID: 33233891     DOI: 10.1021/acs.est.0c05722

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  2 in total

1.  Automated analysis of microplastics based on vibrational spectroscopy: are we measuring the same metrics?

Authors:  Mingtan Dong; Zhenbing She; Xiong Xiong; Guang Ouyang; Zejiao Luo
Journal:  Anal Bioanal Chem       Date:  2022-02-15       Impact factor: 4.478

Review 2.  Analysis of microplastics in drinking water and other clean water samples with micro-Raman and micro-infrared spectroscopy: minimum requirements and best practice guidelines.

Authors:  Darena Schymanski; Barbara E Oßmann; Nizar Benismail; Kada Boukerma; Gerald Dallmann; Elisabeth von der Esch; Dieter Fischer; Franziska Fischer; Douglas Gilliland; Karl Glas; Thomas Hofmann; Andrea Käppler; Sílvia Lacorte; Julie Marco; Maria El Rakwe; Jana Weisser; Cordula Witzig; Nicole Zumbülte; Natalia P Ivleva
Journal:  Anal Bioanal Chem       Date:  2021-07-20       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.