Effect of a reduced donor heart right ventricular distensibility on post-heart transplant haemodynamics.

Yuki Nakamura1, Daisuke Yoshioka1, Hidetsugu Asanoi1, Shigeru Miyagawa1, Yasushi Yoshikawa1, Hiroki Hata1, Ryoto Sakaniwa2, Koichi Toda1, Yoshiki Sawa1.   

Abstract

OBJECTIVES: This study aimed to investigate the characteristics of a reduced right ventricular distensibility after heart transplant.
METHODS: This study enrolled 64 adult patients who underwent heart transplant at our institution. The degree of right ventricular distensibility was quantified by calculating the difference between right atrial pressures (RAPs) of X descent and Y descent (X-Y) from the RAP waveform in right heart catheterization. Histologically, the ratio of the interstitial tissue in myocardial biopsy samples was calculated.
RESULTS: Of the 64 patients, 35 (55%) had a reduced right ventricular distensibility at 1 week after heart transplant (X-Y > 1 mmHg, RD group), and 29 (45%) had a normal right ventricular distensibility (X-Y ≤ 1 mmHg, ND group). The mean RAP and mean pulmonary capillary wedge pressure 1 week after heart transplant in the RD group were significantly higher than that in the ND group. The mean RAP and mean pulmonary capillary wedge pressure in the RD group gradually normalized 12 weeks postoperation. The ratio of the interstitial tissue of biopsy samples significantly correlated with the X-Y value. The number of patients who required inotropic support >14 days was higher in the RD group than in the ND group.
CONCLUSIONS: Reduced donor heart distensibility was a common impairment early after heart transplant. It might result from interstitial oedema in the myocardial tissue of the donor heart. Reduced donor heart distensibility after heart transplant might be associated with early clinical outcomes; however, further investigation is required.
© The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Donor heart; Haemodynamics; Heart transplant; Ventricular distensibility

Mesh:

Year:  2021        PMID: 33232450      PMCID: PMC8906735          DOI: 10.1093/icvts/ivaa222

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  26 in total

1.  Reduced atrial emptying after orthotopic heart transplantation masquerading as restrictive transmitral Doppler flow pattern?*.

Authors:  Patrizio Pascale; Pierre Monney; Xavier Jeanrenaud; Nicole Aebischer; Patrick Yerly; Pierre Vogt; Etienne Pruvot; Jürg Schläpfer
Journal:  Echocardiography       Date:  2011-02       Impact factor: 1.724

Review 2.  Contractile behavior of the left ventricle in diastolic heart failure: with emphasis on regional systolic function.

Authors:  Gerard P Aurigemma; Michael R Zile; William H Gaasch
Journal:  Circulation       Date:  2006-01-17       Impact factor: 29.690

3.  Diastolic dysfunction during acute cardiac allograft rejection.

Authors:  I Amende; R Simon; A Seegers; W Daniel; B Heublein; R Hetzer; A Haverich; W P Hood; P R Lichtlen; R Schützenmeister
Journal:  Circulation       Date:  1990-02       Impact factor: 29.690

Review 4.  Restrictive cardiomyopathy.

Authors:  S S Kushwaha; J T Fallon; V Fuster
Journal:  N Engl J Med       Date:  1997-01-23       Impact factor: 91.245

5.  Right Atrial Pressure Waveform Predicts Right Ventricular Failure After Left Ventricular Assist Device Implantation.

Authors:  Takaaki Samura; Daisuke Yoshioka; Hidetsugu Asanoi; Koichi Toda; Shigeru Miyagawa; Yasushi Yoshikawa; Hiroki Hata; Satoshi Kainuma; Takuji Kawamura; Ai Kawamura; Yasushi Sakata; Yoshiki Sawa
Journal:  Ann Thorac Surg       Date:  2019-06-05       Impact factor: 4.330

6.  Early and late hemodynamic evaluation after cardiac transplantation: a study of 28 cases.

Authors:  T Corcos; C Tamburino; P Léger; E Vaissier; P Rossant; M F Mattei; P Daudon; I Gandjbakhch; A Pavie; A Cabrol
Journal:  J Am Coll Cardiol       Date:  1988-02       Impact factor: 24.094

7.  Modulation of left ventricular diastolic distensibility by collateral flow recruitment during balloon coronary occlusion.

Authors:  H A Remah; H Asanoi; S Joho; A Igawa; T Kameyama; T Nozawa; H Inoue
Journal:  J Am Coll Cardiol       Date:  1999-08       Impact factor: 24.094

8.  Diastolic tissue Doppler indexes correlate with the degree of collagen expression and cross-linking in heart failure and normal ejection fraction.

Authors:  Mario Kasner; Dirk Westermann; Begoña Lopez; Regina Gaub; Felicitas Escher; Uwe Kühl; Heinz-Peter Schultheiss; Carsten Tschöpe
Journal:  J Am Coll Cardiol       Date:  2011-02-22       Impact factor: 24.094

9.  Myocardial structure and function differ in systolic and diastolic heart failure.

Authors:  Loek van Heerebeek; Attila Borbély; Hans W M Niessen; Jean G F Bronzwaer; Jolanda van der Velden; Ger J M Stienen; Wolfgang A Linke; Gerrit J Laarman; Walter J Paulus
Journal:  Circulation       Date:  2006-04-17       Impact factor: 29.690

10.  Effects of crystalloid, blood, and University of Wisconsin perfusates on weight, water content, and left ventricular compliance in an edema-prone, isolated porcine heart model.

Authors:  Z C Weng; A C Nicolosi; P W Detwiler; D T Hsu; S W Schierman; A H Goldstein; H M Spotnitz
Journal:  J Thorac Cardiovasc Surg       Date:  1992-03       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.