Regional variation in the reliability of sweat rate measured via the ventilated capsule technique during passive heating.

Maura M Rutherford1, Ashley P Akerman1, Sean R Notley1, Robert D Meade1, Madison D Schmidt1, Glen P Kenny1.   

Abstract

The ventilated capsule technique is widely used to measure time-dependent changes in sweating in humans. However, evaluations of its reliability (consistency) have been restricted to the forearm, despite extensive regional heterogeneity in the sweating response. Given the importance of such information for experimental design, statistical analysis and interpretation, we determined the reliability of local sweat rate at nine sites during whole-body passive (resting) heating. On three separate occasions, a water-perfused suit was used to increase and clamp oesophageal temperature 0.6, 1.2 and 1.8°C above baseline in 14 young men [24 (SD 5) years of age], while sweat rate was measured at the forehead, chest, abdomen, biceps, forearm, hand, quadriceps, calf and foot using ventilated capsules (3.8 cm2 ). Absolute and relative reliability were determined via the coefficient of variation (CV) and intraclass correlation coefficient (ICC), respectively. At low heat strain (0.6°C), almost all sites had acceptable relative reliability (ICC ≥ 0.70) and moderate absolute reliability (CV < 25%). At moderate heat strain (1.2°C), only the abdomen, hand, quadriceps and foot had acceptable relative reliability, whereas the forehead, abdomen, forearm, hand and quadriceps had moderate absolute reliability. At high heat strain (1.8°C), relative reliability was acceptable at the abdomen, quadriceps, calf and foot, whereas the chest, abdomen, forearm, hand, quadriceps, calf and foot had moderate absolute reliability. Our findings indicate that the measurement site and level of heat strain impact the consistency of local sweat rate measured via the ventilated capsule technique, and we demonstrate the possible implications for research design and data interpretation.
© 2020 The Authors. Experimental Physiology © 2020 The Physiological Society.

Entities:  

Keywords:  body temperature; heat stress; measurement error; power calculation; repeatability; reproducibility; sweat; thermoregulation

Mesh:

Year:  2020        PMID: 33230911     DOI: 10.1113/EP089074

Source DB:  PubMed          Journal:  Exp Physiol        ISSN: 0958-0670            Impact factor:   2.969


  2 in total

1.  Low-Cost Wearable Fluidic Sweat Collection Patch for Continuous Analyte Monitoring and Offline Analysis.

Authors:  Annemarijn S M Steijlen; Kaspar M B Jansen; Jeroen Bastemeijer; Paddy J French; Andre Bossche
Journal:  Anal Chem       Date:  2022-04-29       Impact factor: 8.008

2.  Revisiting regional variation in the age-related reduction in sweat rate during passive heat stress.

Authors:  Madison D Schmidt; Sean R Notley; Robert D Meade; Ashley P Akerman; Maura M Rutherford; Glen P Kenny
Journal:  Physiol Rep       Date:  2022-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.