Literature DB >> 33224809

Prediction of postoperative hematoma occurrence after ultrasound-guided vacuum-assisted breast biopsy in minimally invasive surgery for percutaneous removal of benign breast lesions.

Jianwei Zheng1, Shuyan Cai1, Huimin Song1, Yunlei Wang1, Xiaofeng Han1, Gang Han1, Haoliang Wu1, Zhigang Gao1.   

Abstract

BACKGROUND: The exact factors and mechanisms involved in the development of hematoma after breast ultrasound (US)-guided vacuum-assisted biopsy (VAB) are not clear. This study aimed to analyze the occurrence, prognosis, and risk factors of hematoma after US-guided VAB for the removal of benign breast lesions.
METHODS: This was a retrospective study of consecutive female patients with breast lesions (BI-RADS 3/4a/4b and confirmed as benign by core needle biopsy) removed by percutaneous excisional biopsy by US-guided VAB at the Beijing Chaoyang Hospital from April 2016 to December 2018. Univariable analyses were conducted to identify the factors associated with hematoma (age, nodule size, laterality, nodule location, number of nodules, BI-RADS classification of ultrasound, pathology, breast shape, menstrual period, efficacy time of bandage, and hemostatic agents). Multivariable analysis was performed to identify the factors independently associated with hematoma.
RESULTS: A total of 293 patients (343 breast lesions) were included. Lesion removal was successful in all cases. Hematomas ≥1 cm were found in 39 patients. Finally, 38 (97.4%) hematomas were absorbed completely within 6 months. The multivariable logistic regression analysis revealed that lesion size (P<0.001; OR: 5.775; 95% CI: 2.752-12.121), number of lesions (P=0.011; OR: 3.205, 95% CI: 1.311-7.834), and the efficacy time of bandage 12-24 h (P=0.003; OR: 5.257, 95% CI: 1.792-15.421) were independently associated with hematoma occurrence after US-guided VAB excision of breast lesions. A lesion size cut-off of 23.4 mm (AUC 0.764, 95% CI: 0.692-0.837; 59.0% sensitivity; 80.3% specificity; 77.5% accuracy; P<0.001) could predict hematoma occurrence.
CONCLUSIONS: US-guided excisional VAB can effectively remove benign breast lesions. The factors independently associated with postoperative hematoma are lesion size, lesion number, and effective postoperative compression time of bandage. 2020 Gland Surgery. All rights reserved.

Entities:  

Keywords:  Breast diseases; biopsy, needle; hematoma; minimally invasive surgery; predictive factor; ultrasound

Year:  2020        PMID: 33224809      PMCID: PMC7667065          DOI: 10.21037/gs-20-344

Source DB:  PubMed          Journal:  Gland Surg        ISSN: 2227-684X


  15 in total

1.  [Clinical experience with a handheld vacuum-assisted biopsy system (VACORA® )for mammary lesions].

Authors:  Mao Tokumoto; Shinichiro Kashiwagi; Sae Ishihara; Yuka Asano; Chie Sakimura; Kento Kurata; Yukie Tauchi; Tamami Morisaki; Satoru Noda; Hidemi Kawajiri; Tsutomu Takashima; Naoyoshi Onoda; Kosei Hirakawa
Journal:  Gan To Kagaku Ryoho       Date:  2014-11

2.  Benign Papillomas of the Breast Diagnosed on Large-Gauge Vacuum Biopsy compared with 14 Gauge Core Needle Biopsy - Do they require surgical excision?

Authors:  Jean M Seely; Raman Verma; Ania Kielar; Karl R Smyth; Kalesha Hack; Monica Taljaard; Denis Gravel; Erin Ellison
Journal:  Breast J       Date:  2016-10-31       Impact factor: 2.431

3.  Therapeutic application of ultrasound-guided 8-gauge Mammotome system in presumed benign breast lesions.

Authors:  Hao-jun Luo; Xin Chen; Gang Tu; Jing Wang; Cheng-yi Wu; Guang-lun Yang
Journal:  Breast J       Date:  2011-07-15       Impact factor: 2.431

4.  Potential application of ultrasound-guided vacuum-assisted excision (US-VAE) for well-selected intraductal papillomas of the breast: single-institutional experiences.

Authors:  Kyung Hee Ko; Hye Kyoung Jung; Ji Hyun Youk; Kyung Po Lee
Journal:  Ann Surg Oncol       Date:  2011-09-13       Impact factor: 5.344

Review 5.  Benign breast disease.

Authors:  Mark D Pearlman; Jennifer L Griffin
Journal:  Obstet Gynecol       Date:  2010-09       Impact factor: 7.661

6.  Minimally Invasive Breast Fibroadenoma Excision Using an Ultrasound-Guided Vacuum-Assisted Biopsy Device.

Authors:  Thomas Papathemelis; Stefanie Heim; Michael P Lux; Ines Erhardt; Anton Scharl; Sophia Scharl
Journal:  Geburtshilfe Frauenheilkd       Date:  2017-02       Impact factor: 2.915

7.  Percutaneous excisional biopsy of palpable breast masses under ultrasound visualization.

Authors:  Hernan I Vargas; M Perla Vargas; Katherine Gonzalez; Melissa Burla; Iraj Khalkhali
Journal:  Breast J       Date:  2006 Sep-Oct       Impact factor: 2.431

8.  Outcomes of benign breast papillomas diagnosed at image-guided vacuum-assisted core needle biopsy.

Authors:  Jeffrey R Hawley; Hannah Lawther; Barbaros Selnur Erdal; Vedat O Yildiz; Selin Carkaci
Journal:  Clin Imaging       Date:  2015-02-07       Impact factor: 1.605

9.  Evaluation of two different vacuum-assisted breast biopsy systems: Mammotome(R) system 11G/8G vs. ATEC(R) system 12G/9G.

Authors:  Berndt-Michael Order; Philipp J Schaefer; G Peters; Christel Eckmann-Scholz; Felix Hilpert; Alexander Strauss; Viktoria Warneke; Micaela Mathiak; Martin Heller; Walter Jonat; Fritz Kw Schaefer
Journal:  Acta Radiol       Date:  2013-01-14       Impact factor: 1.990

10.  Benign papillomas diagnosed on large-gauge vacuum-assisted core needle biopsy which span <1.5 cm do not need surgical excision.

Authors:  Andrew D Mosier; Joren Keylock; Donald V Smith
Journal:  Breast J       Date:  2013-09-19       Impact factor: 2.431

View more
  3 in total

1.  Emergency embolization for breast pseudoaneurysm following vacuum-assisted biopsy: a case report.

Authors:  Nguyen Thai Binh; Nguyen Minh Duc; Thieu-Thi Tra My; Le Viet Dung; Doan Tien Luu; Le Tuan Linh
Journal:  Pan Afr Med J       Date:  2021-02-08

2.  The Efficacy of Thrombin-Gelatin Matrix in Hemostasis for Large Breast Tumor after Vacuum-Assisted Breast Biopsy.

Authors:  Yen-Dun Tony Tzeng; Shiuh-Inn Liu; Being-Whey Wang; Yu-Chia Chen; Po-Ming Chang; I-Shu Chen; Jim Jinn-Chyuan Sheu; Jui-Hu Hsiao
Journal:  J Pers Med       Date:  2022-02-17

Review 3.  Efficacy and safety of microwave ablation for benign breast lesions: a systematic review and meta-analysis.

Authors:  Chuchu Xu; Qinghong Yu; Mengqian Wang; Jiayan Zhu; Zimei Yang; Shan Liu; Xiufei Gao
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2022-04-20       Impact factor: 1.627

  3 in total