Literature DB >> 33222409

An update on continuous-wave cyclophotocoagulation (CW-CPC) and micropulse transscleral laser treatment (MP-TLT) for adult and paediatric refractory glaucoma.

Soufiane Souissi1, Yannick Le Mer1, Florence Metge2, Alexandre Portmann2, Christophe Baudouin3, Antoine Labbé3, Pascale Hamard3.   

Abstract

PURPOSE: Continuous-wave cyclophotocoagulation (CW-CPC) is often preferred to medical and surgical treatments for managing refractory glaucoma. This review summarizes diode CW-CPC indications, history, histopathology, methods, efficacy and safety. It also provides an overview of the latest data available on micropulse transscleral laser treatment (MP-TLT) that uses repetitive micropulses of diode laser energy in an off-and-on cyclical fashion.
METHODS: A literature review was conducted on transscleral CW-CPC (CW-TSCPC), endoscopic CPC (ECP) and MP-TLT. Relevant series of adult and paediatric patients were included for assessing the procedures.
RESULTS: Regarding CW-TCPC, highly variable success rates are reported in the literature, depending on the definition of success, type of underlying glaucoma, energy settings, follow-up duration and retreatment rates. CW-CPC often needs to be repeated, especially in paediatric patients. CW-CPC exposes to risks of inflammation and chronic ocular hypotony or phthisis with irreversible visual loss. CW-TSCPC has mainly been used in very severe forms of glaucoma, in painful eyes with limited visual potential or after filtering surgery failure. Published data on ECP are more limited but overall good success rates have been reported. Through the direct visualization of the targeted ciliary body in anatomically abnormal eyes, ECP is the preferred surgical procedure in paediatric refractory glaucoma. Complication rates are relatively low after ECP; however, large studies with long-term follow-up are needed. ECP may be used in difficult, refractory cases, but it is often used earlier when combined with cataract surgery. Despite limited data on the exact mechanism of action of MP-TLT and a lack of standardization of laser settings, the first data from heterogeneous case series shows that it has a similar efficacy and a better safety profile compared to CW-TSCPC in the medium term.
CONCLUSION: Although they may lead to sight-threatening complications, both CW-TSCPC and ECP seem effective. ECP appears to be superior to CW-TSCPC in paediatric refractory glaucoma. Unlike ECP combined with cataract surgery, evidence supporting a wider use of CW-TSCPC and MP-TLT in earlier stages of neuropathy is lacking. While it now appears that the safety profile of MP-TLT is superior to that of CW-CPC, robust prospective comparative studies including homogeneous and well-defined cohorts of patients are still needed to confirm an at least comparable efficacy in the long term.
© 2020 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  ciliary body; continuous-wave transscleral cyclophotocoagulation; endoscopic cyclophotocoagulation; intraocular pressure; micropulse transscleral laser treatment; refractory glaucoma

Mesh:

Year:  2020        PMID: 33222409     DOI: 10.1111/aos.14661

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  7 in total

1.  The Histopathology of Two Eyes Enucleated after Continuous Transscleral and Micropulse Transscleral Cyclophotocoagulation for Refractory Secondary Glaucoma.

Authors:  Imani M Williams; Vamsee K Neerukonda; Anna M Stagner
Journal:  Ocul Oncol Pathol       Date:  2022-01-24

Review 2.  Clinical outcomes of slow-coagulation continuous-wave transscleral cyclophotocoagulation laser for treatment of glaucoma.

Authors:  Mohamed M Khodeiry; Xiangxiang Liu; Richard K Lee
Journal:  Curr Opin Ophthalmol       Date:  2022-02-23       Impact factor: 4.299

3.  Changes After a Month Following Micropulse Cyclophotocoagulation in Normal Porcine Eyes.

Authors:  So Min Ahn; Mihyun Choi; Seong-Woo Kim; Yong Yeon Kim
Journal:  Transl Vis Sci Technol       Date:  2021-11-01       Impact factor: 3.283

4.  Outcomes of a combination of augmented MicroPulse and limited Continuous Wave Cyclophotocoagulation in patients with refractory glaucoma.

Authors:  Sanchay Gupta; Enchi Kristina Chang; Marika Chachanidze; Nathan Hall; Cameron Neeson; Emma Klug; Ta Chen Chang; David A Solá-Del Valle
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-10-25       Impact factor: 3.117

5.  Ciliochoroidal effusion and its association with the outcomes of micropulse transscleral laser therapy in glaucoma patients: a pilot study.

Authors:  Sunee Chansangpetch; Natnaree Taechajongjintana; Kitiya Ratanawongphaibul; Rath Itthipanichpong; Anita Manassakorn; Visanee Tantisevi; Prin Rojanapongpun; Shan C Lin
Journal:  Sci Rep       Date:  2022-09-30       Impact factor: 4.996

6.  Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma.

Authors:  Di Chen; Xiu-Juan Guo; Shu-Ke Luo; Yan Lu; Xiu-Rong Tang
Journal:  BMC Ophthalmol       Date:  2022-10-07       Impact factor: 2.086

7.  First and second transscleral cyclophotocoagulation treatments provide similar intraocular pressure-lowering efficacy in patients with refractory glaucoma.

Authors:  Enrico Bernardi; Marc Töteberg-Harms
Journal:  Int Ophthalmol       Date:  2022-02-03       Impact factor: 2.029

  7 in total